    keyword=End_of_Run_3042
    ****************************
     Run Number: 3042
     End of Run Comment:
    Run_type=Production,target_type=Iron 50 degs  Right,beam_e0=0.6458457,beam_raster=on,leftarm_p=0.13310,leftarm_theta=120,leftarm_colli=out,rightarm_p=0.15321,rightarm_theta=120,rightarm_colli=out,comment_text=
     
    
    PRESCALE FACTORS:ps1=16777212   ps2=16777215   ps3=1   ps4=8   ps5=65535   ps6=65535   ps7=9999   ps8=65535   
    
    EVENTS   : 527593       
    TIME     : 19.757 mins  
    
    DEAD TIME:   6.56%      
    
    TRIGGER RATES:   PRES/REAL
    T3:454.4/454.4 Hz   T4:21.9/175.3 Hz   T5: 0.0/0.0  Hz   T8: 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T3: 538670/538670   T4:  25982/207862   T5:      0/0        T8:     18/1213865  
    
    AVERAGE CURRENT
    BCM x1 : 48.8135uA  BCM x3 : 48.8549uA  BCM x10: 42.1764uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 : 0.05792        BCM u3 : 0.05792        BCM u10: 0.04968        
    
    BCM d1 : 0.05781        BCM d3 : 0.05791        BCM d10: 0.05031        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 3042 at Thu Nov 29 20:25:03 EST 2007
    
    Wien angle : 12.3659
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.133118
    Left Arm arm angle : 120
    Right Arm D1 momentum : 0.152945
    Right Arm arm angle : 120
    HALLA:p : 646.069
    HALLA:dpp : 0.000265741
    Tiefenbach Hall A energy : 646.069
    Left Arm Top VDC Current : 3.56445
    Left Arm Bottom VDC Current : 0.390625
    Left Arm Q1 momentum : 0.133118
    Left Arm Q1 power supply : 97.0932
    Left Arm Q1 gauss meter : -0.008198
    Left Arm Q2 gauss meter : 0.03039
    Left Arm Q2 power supply current : 55.9494
    Left Arm Q2 momentum : 0.13309
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 42.2315
    Left Arm D1 momentum : 0.133118
    Left Arm D1 NMR : 0.168165
    Left Arm Q3 gauss meter : -0.02582
    Left Arm Q3 power supply current : 50.5271
    Left Arm Q3 momentum : 0.133018
    Left Arm Q3 power supply polarity : disabled
    Right Arm Q1 momentum : 0.152704
    Right Arm Q1 power supply : 111.673
    Right Arm Q1 gauss meter : -0.0029
    Right Arm Q2 power supply current : 64.9198
    Right Arm Q2 momentum : 0.153054
    Right Arm Q2 gauss meter : 0.03459
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 45.6185
    Right Arm D1 momentum : 0.152917
    Right Arm D1 NMR : 0.472249
    Right Arm Q3 power supply current : 60.0714
    Right Arm Q3 momentum : 0.153084
    Right Arm Q3 gauss meter : 0.02706
    Right Arm Q3 power supply polarity : disabled
    Average current of the two cavities : 49.3379
    Current on Unser monitor : 60.1457
    Current on Upstream bcm : 49.5349
    Current on Downstream bcm : 49.1408
    Upstream Cavity Coefficient : 43.377
    Downstream Cavity Coefficient : 42.913
    Current on IBC0L02 (source) : 128.439
    Hall C Current : 79.41
    MBSY1c magnet current (amp) : 26.4309
    MBSY1c Bdl : 161063
    Hall A momentum (Tiefenbach) (HALLA:p) : 646.071
    Hall A momentum orbit correction (dpp) : 0.000268569
    Hall A setup momentum (MMSHLAE) : 645.369
    Hall A energy (halla_MeV) : 646.071
    Hall C energy (hallc_MeV) : 1876.33
    Delta(E)/E width (MV_AI_DXWID) : 0.80087
    IPM1C12.XPOS : -1.27168
    IPM1H04A.XPOS : -1.09401
    IPM1H04A.YPOS : -0.0861885
    IPM1H04B.XPOS : -1.00105
    IPM1H04B.YPOS : 0.00688869
    Left Arm Collimator : 0.871338
    HacL_HPE1313A:0_Ch58 : -0.319336
    HacL_HPE1313A:0_Ch55 : 22.7051
    HacL_HPE1313A:0_Ch54 : -0.28125
    SLI data valid? : Yes
    SLI horiz size mm : 0.300841
    SLI Energy spread *10^5 : 5.57113
    SLI x position : 1.40124
    SLI vert. size mm : 0.101054
    SLI y position : 1.72019