Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name adev

    Log entry time 20:48:23 on November 29, 2007

    Entry number 217132

    keyword=End_of_Run_21279
    ****************************
     Run Number: 21279
     End of Run Comment:
    Run_type=Production,target_type=Iron 50 degs  Right,beam_e0=0.6458457,beam_raster=on,beam_halfwaveplate=out,leftarm_p=0.12418,leftarm_theta=120,leftarm_colli=out,rightarm_p=0.15321,rightarm_theta=120,rightarm_colli=out,comment_text=
     
    
    PRESCALE FACTORS:ps1=1   ps2=7   ps3=16777215   ps4=16777215   ps5=65535   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS   : 395124       
    TIME     : 18.841 mins  
    
    DEAD TIME:   5.03%      
    
    TRIGGER RATES:   PRES/REAL
    T1:349.4/349.4 Hz   T2:18.7/131.0 Hz   T8: 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1: 394935/394935   T2:  21148/148039   T8:     17/1157564  
    
    AVERAGE CURRENT
    BCM x1 : 48.8399uA  BCM x3 : 77.1390uA  BCM x10: 21.2197uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 : 0.0553         BCM u3 : 0.05527        BCM u10: -3.055E-07     
    
    BCM d1 : 0.05512        BCM d3 : 0.1191         BCM d10: 0.04798        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 21279 at Thu Nov 29 20:48:20 EST 2007
    
    Wien angle : 12.3659
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.124154
    Left Arm arm angle : 120
    Right Arm D1 momentum : 0.153054
    Right Arm arm angle : 120
    HALLA:p : 646.052
    HALLA:dpp : 0.000239099
    Tiefenbach Hall A energy : 646.052
    Left Arm Top VDC Current : -1.36719
    Left Arm Bottom VDC Current : 0.78125
    Left Arm Q1 momentum : 0.124028
    Left Arm Q1 power supply : 90.3639
    Left Arm Q1 gauss meter : -0.007621
    Left Arm Q2 gauss meter : 0.02831
    Left Arm Q2 power supply current : 51.9892
    Left Arm Q2 momentum : 0.123853
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 39.166
    Left Arm D1 momentum : 0.124154
    Left Arm D1 NMR : 0.405568
    Left Arm Q3 gauss meter : -0.02404
    Left Arm Q3 power supply current : 47.0176
    Left Arm Q3 momentum : 0.124162
    Left Arm Q3 power supply polarity : disabled
    Right Arm Q1 momentum : 0.153181
    Right Arm Q1 power supply : 112.047
    Right Arm Q1 gauss meter : -0.002909
    Right Arm Q2 power supply current : 64.9196
    Right Arm Q2 momentum : 0.152966
    Right Arm Q2 gauss meter : 0.03459
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 47.3559
    Right Arm D1 momentum : 0.153026
    Right Arm D1 NMR : 0.165055
    Right Arm Q3 power supply current : 60.0714
    Right Arm Q3 momentum : 0.153028
    Right Arm Q3 gauss meter : 0.02704
    Right Arm Q3 power supply polarity : disabled
    Average current of the two cavities : 50.5536
    Current on Unser monitor : 61.7835
    Current on Upstream bcm : 50.6072
    Current on Downstream bcm : 50.5
    Upstream Cavity Coefficient : 43.377
    Downstream Cavity Coefficient : 42.913
    Current on IBC0L02 (source) : 129.672
    Hall C Current : 78.75
    MBSY1c magnet current (amp) : 26.4309
    MBSY1c Bdl : 161063
    Hall A momentum (Tiefenbach) (HALLA:p) : 646.057
    Hall A momentum orbit correction (dpp) : 0.000247181
    Hall A setup momentum (MMSHLAE) : 645.369
    Hall A energy (halla_MeV) : 646.057
    Hall C energy (hallc_MeV) : 1876.34
    Delta(E)/E width (MV_AI_DXWID) : 0.760693
    IPM1C12.XPOS : -1.24969
    IPM1H04A.XPOS : -1.08575
    IPM1H04A.YPOS : -0.0868544
    IPM1H04B.XPOS : -0.998214
    IPM1H04B.YPOS : 0.00483251
    Left Arm Collimator : 0.871387
    HacL_HPE1313A:0_Ch58 : -0.318848
    HacL_HPE1313A:0_Ch55 : 22.7539
    HacL_HPE1313A:0_Ch54 : -0.28125
    SLI data valid? : Yes
    SLI horiz size mm : 0.301875
    SLI Energy spread *10^5 : 5.59028
    SLI x position : 1.40124
    SLI vert. size mm : 0.0998587
    SLI y position : 1.7277