    Entry number 217139

    keyword=End_of_Run_21280
    ****************************
     Run Number: 21280
     End of Run Comment:
    Run_type=Production,target_type=Carbon 50 degs Right,beam_e0=0.6458457,beam_raster=on,beam_halfwaveplate=out,leftarm_p=0.12418,leftarm_theta=120,leftarm_colli=out,rightarm_p=0.15321,rightarm_theta=120,rightarm_colli=out,comment_text=
     
    
    PRESCALE FACTORS:ps1=1   ps2=2   ps3=16777215   ps4=16777215   ps5=65535   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS   : 384538       
    TIME     : 19.904 mins  
    
    DEAD TIME:   4.68%      
    
    TRIGGER RATES:   PRES/REAL
    T1:321.4/321.4 Hz   T2:16.4/32.8 Hz   T8: 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1: 383818/383818   T2:  19613/39227    T8:     18/1222893  
    
    AVERAGE CURRENT
    BCM x1 : 50.1269uA  BCM x3 : 78.1787uA  BCM x10: 21.7862uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 : 0.05996        BCM u3 : 0.05993        BCM u10: -7.596E-06     
    
    BCM d1 : 0.05977        BCM d3 : 0.1268         BCM d10: 0.05204        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 21280 at Thu Nov 29 21:12:12 EST 2007
    
    Wien angle : 12.3659
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.124154
    Left Arm arm angle : 120
    Right Arm D1 momentum : 0.153081
    Right Arm arm angle : 120
    HALLA:p : 646.064
    HALLA:dpp : 0.000257422
    Tiefenbach Hall A energy : 646.064
    Left Arm Top VDC Current : -1.85547
    Left Arm Bottom VDC Current : -1.5625
    Left Arm Q1 momentum : 0.123934
    Left Arm Q1 power supply : 90.3105
    Left Arm Q1 gauss meter : -0.007612
    Left Arm Q2 gauss meter : 0.0283
    Left Arm Q2 power supply current : 51.9893
    Left Arm Q2 momentum : 0.123809
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 39.1711
    Left Arm D1 momentum : 0.124154
    Left Arm D1 NMR : 0.305601
    Left Arm Q3 gauss meter : -0.02404
    Left Arm Q3 power supply current : 47.0174
    Left Arm Q3 momentum : 0.124112
    Left Arm Q3 power supply polarity : disabled
    Right Arm Q1 momentum : 0.153659
    Right Arm Q1 power supply : 112.207
    Right Arm Q1 gauss meter : -0.002919
    Right Arm Q2 power supply current : 64.9196
    Right Arm Q2 momentum : 0.152966
    Right Arm Q2 gauss meter : 0.03459
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 48.4436
    Right Arm D1 momentum : 0.153081
    Right Arm D1 NMR : 0.163648
    Right Arm Q3 power supply current : 60.0719
    Right Arm Q3 momentum : 0.15314
    Right Arm Q3 gauss meter : 0.02704
    Right Arm Q3 power supply polarity : disabled
    Average current of the two cavities : 51.2122
    Current on Unser monitor : 62.9938
    Current on Upstream bcm : 51.3951
    Current on Downstream bcm : 51.0293
    Upstream Cavity Coefficient : 43.377
    Downstream Cavity Coefficient : 42.913
    Current on IBC0L02 (source) : 128.705
    Hall C Current : 78.39
    MBSY1c magnet current (amp) : 26.4309
    MBSY1c Bdl : 161063
    Hall A momentum (Tiefenbach) (HALLA:p) : 646.059
    Hall A momentum orbit correction (dpp) : 0.000250608
    Hall A setup momentum (MMSHLAE) : 645.369
    Hall A energy (halla_MeV) : 646.06
    Hall C energy (hallc_MeV) : 1876.34
    Delta(E)/E width (MV_AI_DXWID) : 0.720827
    IPM1C12.XPOS : -1.25448
    IPM1H04A.XPOS : -1.08427
    IPM1H04A.YPOS : -0.0753488
    IPM1H04B.XPOS : -0.993749
    IPM1H04B.YPOS : 0.00512439
    Left Arm Collimator : 0.871387
    HacL_HPE1313A:0_Ch58 : -0.318848
    HacL_HPE1313A:0_Ch55 : 22.6562
    HacL_HPE1313A:0_Ch54 : -0.28125
    SLI data valid? : Yes
    SLI horiz size mm : 0.300421
    SLI Energy spread *10^5 : 5.56336
    SLI x position : 1.38634
    SLI vert. size mm : 0.0995513
    SLI y position : 1.74272