Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 21:24:04 on November 29, 2007

    Entry number 217144

    keyword=End_of_Run_3045
    ****************************
     Run Number: 3045
     End of Run Comment:
    Run_type=Production,target_type=LH2 15cm Loop3,beam_e0=0.6458457,beam_raster=on,leftarm_p=0.12418,leftarm_theta=120,leftarm_colli=out,rightarm_p=0.15321,rightarm_theta=120,rightarm_colli=out,comment_text=
     
    
    PRESCALE FACTORS:ps1=16777212   ps2=16777215   ps3=1   ps4=12   ps5=65535   ps6=65535   ps7=9999   ps8=65535   
    
    EVENTS   : 342186       
    TIME     : 5.203 mins  
    
    DEAD TIME:  17.18%      
    
    TRIGGER RATES:   PRES/REAL
    T3:1300.8/1300.8 Hz   T4:23.1/276.6 Hz   T5: 0.0/0.0  Hz   T8: 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T3: 406032/406032   T4:   7196/86352    T5:      0/0        T8:      4/319642   
    
    AVERAGE CURRENT
    BCM x1 : 44.3015uA  BCM x3 : 44.3491uA  BCM x10: 38.6248uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 : 0.01384        BCM u3 : 0.01384        BCM u10: 0.01199        
    
    BCM d1 : 0.01382        BCM d3 : 0.01385        BCM d10: 0.01212        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 3045 at Thu Nov 29 21:24:02 EST 2007
    
    Wien angle : 12.3659
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.124182
    Left Arm arm angle : 120
    Right Arm D1 momentum : 0.153135
    Right Arm arm angle : 120
    HALLA:p : 646.054
    HALLA:dpp : 0.00024254
    Tiefenbach Hall A energy : 646.054
    Left Arm Top VDC Current : -2.14844
    Left Arm Bottom VDC Current : 3.22266
    Left Arm Q1 momentum : 0.124263
    Left Arm Q1 power supply : 90.3105
    Left Arm Q1 gauss meter : -0.007633
    Left Arm Q2 gauss meter : 0.02834
    Left Arm Q2 power supply current : 51.9897
    Left Arm Q2 momentum : 0.123985
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 39.1692
    Left Arm D1 momentum : 0.124182
    Left Arm D1 NMR : 0.158153
    Left Arm Q3 gauss meter : -0.02405
    Left Arm Q3 power supply current : 47.0178
    Left Arm Q3 momentum : 0.124162
    Left Arm Q3 power supply polarity : disabled
    Right Arm Q1 momentum : 0.153181
    Right Arm Q1 power supply : 111.887
    Right Arm Q1 gauss meter : -0.002901
    Right Arm Q2 power supply current : 64.9203
    Right Arm Q2 momentum : 0.153054
    Right Arm Q2 gauss meter : 0.0346
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 48.8772
    Right Arm D1 momentum : 0.153135
    Right Arm D1 NMR : 0.226394
    Right Arm Q3 power supply current : 60.0718
    Right Arm Q3 momentum : 0.15314
    Right Arm Q3 gauss meter : 0.02705
    Right Arm Q3 power supply polarity : disabled
    Average current of the two cavities : 49.9838
    Current on Unser monitor : 61.9145
    Current on Upstream bcm : 50.0988
    Current on Downstream bcm : 49.8689
    Upstream Cavity Coefficient : 43.377
    Downstream Cavity Coefficient : 42.913
    Current on IBC0L02 (source) : 128.928
    Hall C Current : 81.15
    MBSY1c magnet current (amp) : 26.4309
    MBSY1c Bdl : 161063
    Hall A momentum (Tiefenbach) (HALLA:p) : 646.059
    Hall A momentum orbit correction (dpp) : 0.000250536
    Hall A setup momentum (MMSHLAE) : 645.369
    Hall A energy (halla_MeV) : 646.06
    Hall C energy (hallc_MeV) : 1876.33
    Delta(E)/E width (MV_AI_DXWID) : 0.704726
    IPM1C12.XPOS : -1.23396
    IPM1H04A.XPOS : -1.06257
    IPM1H04A.YPOS : -0.0972086
    IPM1H04B.XPOS : -0.972851
    IPM1H04B.YPOS : -0.00697434
    Left Arm Collimator : 0.871387
    HacL_HPE1313A:0_Ch58 : -0.318848
    HacL_HPE1313A:0_Ch55 : 22.7051
    HacL_HPE1313A:0_Ch54 : -0.280762
    SLI data valid? : Yes
    SLI horiz size mm : 0.299762
    SLI Energy spread *10^5 : 5.55115
    SLI x position : 1.38634
    SLI vert. size mm : 0.103216
    SLI y position : 1.7277