Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 21:52:15 on November 29, 2007

    Entry number 217152

    keyword=End_of_Run_3046
    ****************************
     Run Number: 3046
     End of Run Comment:
    Run_type=Production,target_type=LH2 15cm + Pb foil Loop3,beam_e0=0.6458457,beam_raster=on,leftarm_p=0.12418,leftarm_theta=120,leftarm_colli=out,rightarm_p=0.15321,rightarm_theta=120,rightarm_colli=out,comment_text=
     
    
    PRESCALE FACTORS:ps1=16777212   ps2=16777215   ps3=2   ps4=35   ps5=65535   ps6=65535   ps7=9999   ps8=65535   
    
    EVENTS   : 1523662      
    TIME     : 23.278 mins  
    
    DEAD TIME:   4.30%      
    
    TRIGGER RATES:   PRES/REAL
    T3:1118.6/2237.2 Hz   T4:21.4/748.5 Hz   T5: 0.0/0.0  Hz   T8: 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T3:1562342/3124685  T4:  29867/1045345  T5:      0/0        T8:     21/1430197  
    
    AVERAGE CURRENT
    BCM x1 : 50.4488uA  BCM x3 : 50.5104uA  BCM x10: 43.4919uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 : 0.07052        BCM u3 : 0.07051        BCM u10: 0.06038        
    
    BCM d1 : 0.0704         BCM d3 : 0.07058        BCM d10: 0.06111        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 3046 at Thu Nov 29 21:52:12 EST 2007
    
    Wien angle : 12.3659
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.124182
    Left Arm arm angle : 120
    Right Arm D1 momentum : 0.153108
    Right Arm arm angle : 120
    HALLA:p : 646.068
    HALLA:dpp : 0.000264449
    Tiefenbach Hall A energy : 646.069
    Left Arm Top VDC Current : 0.244141
    Left Arm Bottom VDC Current : -0.78125
    Left Arm Q1 momentum : 0.124153
    Left Arm Q1 power supply : 90.3105
    Left Arm Q1 gauss meter : -0.007626
    Left Arm Q2 gauss meter : 0.02838
    Left Arm Q2 power supply current : 51.9895
    Left Arm Q2 momentum : 0.124161
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 39.166
    Left Arm D1 momentum : 0.124182
    Left Arm D1 NMR : 0.234414
    Left Arm Q3 gauss meter : -0.02404
    Left Arm Q3 power supply current : 47.0176
    Left Arm Q3 momentum : 0.124112
    Left Arm Q3 power supply polarity : disabled
    Right Arm Q1 momentum : 0.154083
    Right Arm Q1 power supply : 112.154
    Right Arm Q1 gauss meter : -0.002926
    Right Arm Q2 power supply current : 64.9203
    Right Arm Q2 momentum : 0.15301
    Right Arm Q2 gauss meter : 0.0346
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 49.6655
    Right Arm D1 momentum : 0.153108
    Right Arm D1 NMR : 0.339143
    Right Arm Q3 power supply current : 60.0716
    Right Arm Q3 momentum : 0.15314
    Right Arm Q3 gauss meter : 0.02706
    Right Arm Q3 power supply polarity : disabled
    Average current of the two cavities : 50.2356
    Current on Unser monitor : 60.7318
    Current on Upstream bcm : 50.2608
    Current on Downstream bcm : 50.2105
    Upstream Cavity Coefficient : 43.377
    Downstream Cavity Coefficient : 42.913
    Current on IBC0L02 (source) : 128.542
    Hall C Current : 79.08
    MBSY1c magnet current (amp) : 26.4309
    MBSY1c Bdl : 161063
    Hall A momentum (Tiefenbach) (HALLA:p) : 646.064
    Hall A momentum orbit correction (dpp) : 0.000258505
    Hall A setup momentum (MMSHLAE) : 645.369
    Hall A energy (halla_MeV) : 646.064
    Hall C energy (hallc_MeV) : 1876.34
    Delta(E)/E width (MV_AI_DXWID) : 0.787619
    IPM1C12.XPOS : -1.27363
    IPM1H04A.XPOS : -1.06877
    IPM1H04A.YPOS : -0.0761579
    IPM1H04B.XPOS : -0.977927
    IPM1H04B.YPOS : -0.00124812
    Left Arm Collimator : 0.871338
    HacL_HPE1313A:0_Ch58 : -0.318848
    HacL_HPE1313A:0_Ch55 : 22.7051
    HacL_HPE1313A:0_Ch54 : -0.28125
    SLI data valid? : Yes
    SLI horiz size mm : 0.294552
    SLI Energy spread *10^5 : 5.45466
    SLI x position : 1.40124
    SLI vert. size mm : 0.0797998
    SLI y position : 1.72019