Log entry time 22:03:59 on November 29, 2007
Entry number 217157
keyword=End_of_Run_3047
****************************
Run Number: 3047
End of Run Comment:
Run_type=Production,target_type=4He 10cm Loop1 High Pressure,beam_e0=0.6458457,beam_raster=on,leftarm_p=0.12418,leftarm_theta=120,leftarm_colli=out,rightarm_p=0.15321,rightarm_theta=120,rightarm_colli=out,comment_text=
PRESCALE FACTORS:ps1=16777212 ps2=16777215 ps3=3 ps4=15 ps5=65535 ps6=65535 ps7=9999 ps8=65535
EVENTS : 305357
TIME : 4.909 mins
DEAD TIME: 2.97%
TRIGGER RATES: PRES/REAL
T3:1044.9/3134.7 Hz T4:23.6/353.6 Hz T5: 0.0/0.0 Hz T8: 0.0/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T3: 307780/923341 T4: 6944/104167 T5: 0/0 T8: 4/301626
AVERAGE CURRENT
BCM x1 : 49.9370uA BCM x3 : 49.9948uA BCM x10: 43.3536uA
APPROXIMATE BCM CHARGES (C)
BCM u1 : 0.01473 BCM u3 : 0.01473 BCM u10: 0.01267
BCM d1 : 0.01469 BCM d3 : 0.01473 BCM d10: 0.01287
****************************
End-of-run EPICS data for Run Number 3047 at Thu Nov 29 22:03:57 EST 2007
Wien angle : 12.3659
Half-wave plate (off=out) : IN
Left Arm D1 momentum : 0.12421
Left Arm arm angle : 120
Right Arm D1 momentum : 0.153163
Right Arm arm angle : 120
HALLA:p : 646.062
HALLA:dpp : 0.000254618
Tiefenbach Hall A energy : 646.062
Left Arm Top VDC Current : 4.3457
Left Arm Bottom VDC Current : -1.31836
Left Arm Q1 momentum : 0.124294
Left Arm Q1 power supply : 90.3105
Left Arm Q1 gauss meter : -0.007637
Left Arm Q2 gauss meter : 0.02838
Left Arm Q2 power supply current : 51.9895
Left Arm Q2 momentum : 0.124117
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 39.167
Left Arm D1 momentum : 0.12421
Left Arm D1 NMR : 0.298624
Left Arm Q3 gauss meter : -0.02404
Left Arm Q3 power supply current : 47.0179
Left Arm Q3 momentum : 0.124112
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 momentum : 0.152545
Right Arm Q1 power supply : 111.727
Right Arm Q1 gauss meter : -0.002897
Right Arm Q2 power supply current : 64.9206
Right Arm Q2 momentum : 0.153054
Right Arm Q2 gauss meter : 0.03459
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 49.9165
Right Arm D1 momentum : 0.153163
Right Arm D1 NMR : 0.342673
Right Arm Q3 power supply current : 60.072
Right Arm Q3 momentum : 0.15314
Right Arm Q3 gauss meter : 0.02704
Right Arm Q3 power supply polarity : disabled
Average current of the two cavities : 49.5232
Current on Unser monitor : 60.2784
Current on Upstream bcm : 49.5936
Current on Downstream bcm : 49.4528
Upstream Cavity Coefficient : 43.377
Downstream Cavity Coefficient : 42.913
Current on IBC0L02 (source) : 129.017
Hall C Current : 79.83
MBSY1c magnet current (amp) : 26.4309
MBSY1c Bdl : 161063
Hall A momentum (Tiefenbach) (HALLA:p) : 646.059
Hall A momentum orbit correction (dpp) : 0.000250196
Hall A setup momentum (MMSHLAE) : 645.369
Hall A energy (halla_MeV) : 646.059
Hall C energy (hallc_MeV) : 1876.33
Delta(E)/E width (MV_AI_DXWID) : 0.77641
IPM1C12.XPOS : -1.24263
IPM1H04A.XPOS : -1.06766
IPM1H04A.YPOS : -0.0868677
IPM1H04B.XPOS : -0.976909
IPM1H04B.YPOS : 0.00715715
Left Arm Collimator : 0.871436
HacL_HPE1313A:0_Ch58 : -0.319336
HacL_HPE1313A:0_Ch55 : 22.7539
HacL_HPE1313A:0_Ch54 : -0.280762
SLI data valid? : Yes
SLI horiz size mm : 0.293674
SLI Energy spread *10^5 : 5.4384
SLI x position : 1.40124
SLI vert. size mm : 0.107239
SLI y position : 1.72019