    Log entry time 22:04:00 on November 29, 2007

    Entry number 217158

    keyword=End_of_Run_21283
    ****************************
     Run Number: 21283
     End of Run Comment:
    Run_type=Production,target_type=4He 10cm Loop1 High Pressure,beam_e0=0.6458457,beam_raster=on,beam_halfwaveplate=out,leftarm_p=0.12418,leftarm_theta=120,leftarm_colli=out,rightarm_p=0.15321,rightarm_theta=120,rightarm_colli=out,comment_text=
     
    
    PRESCALE FACTORS:ps1=4   ps2=15   ps3=16777215   ps4=16777215   ps5=65535   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS   : 279753       
    TIME     : 4.909 mins  
    
    DEAD TIME:   2.01%      
    
    TRIGGER RATES:   PRES/REAL
    T1:949.9/3799.7 Hz   T2:19.4/290.9 Hz   T8: 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1: 279785/1119141  T2:   5712/85689    T8:      4/301606   
    
    AVERAGE CURRENT
    BCM x1 : 50.0094uA  BCM x3 : 79.6262uA  BCM x10: 21.8438uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 : 0.01476        BCM u3 : 0.01475        BCM u10: 3.596E-05      
    
    BCM d1 : 0.0147         BCM d3 : 0.03216        BCM d10: 0.01283        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 21283 at Thu Nov 29 22:03:58 EST 2007
    
    Wien angle : 12.3659
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.12421
    Left Arm arm angle : 120
    Right Arm D1 momentum : 0.153163
    Right Arm arm angle : 120
    HALLA:p : 646.059
    HALLA:dpp : 0.000250196
    Tiefenbach Hall A energy : 646.059
    Left Arm Top VDC Current : -0.292969
    Left Arm Bottom VDC Current : 2.34375
    Left Arm Q1 momentum : 0.124325
    Left Arm Q1 power supply : 90.3105
    Left Arm Q1 gauss meter : -0.007637
    Left Arm Q2 gauss meter : 0.02838
    Left Arm Q2 power supply current : 51.9892
    Left Arm Q2 momentum : 0.124161
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 39.167
    Left Arm D1 momentum : 0.124154
    Left Arm D1 NMR : 0.298624
    Left Arm Q3 gauss meter : -0.02404
    Left Arm Q3 power supply current : 47.0181
    Left Arm Q3 momentum : 0.124112
    Left Arm Q3 power supply polarity : disabled
    Right Arm Q1 momentum : 0.152121
    Right Arm Q1 power supply : 111.727
    Right Arm Q1 gauss meter : -0.002889
    Right Arm Q2 power supply current : 64.9203
    Right Arm Q2 momentum : 0.152966
    Right Arm Q2 gauss meter : 0.03459
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 49.9185
    Right Arm D1 momentum : 0.153163
    Right Arm D1 NMR : 0.342673
    Right Arm Q3 power supply current : 60.0719
    Right Arm Q3 momentum : 0.153028
    Right Arm Q3 gauss meter : 0.02704
    Right Arm Q3 power supply polarity : disabled
    Average current of the two cavities : 49.4878
    Current on Unser monitor : 60.2784
    Current on Upstream bcm : 49.5936
    Current on Downstream bcm : 49.3821
    Upstream Cavity Coefficient : 43.377
    Downstream Cavity Coefficient : 42.913
    Current on IBC0L02 (source) : 129.017
    Hall C Current : 79.95
    MBSY1c magnet current (amp) : 26.4309
    MBSY1c Bdl : 161063
    Hall A momentum (Tiefenbach) (HALLA:p) : 646.058
    Hall A momentum orbit correction (dpp) : 0.000248976
    Hall A setup momentum (MMSHLAE) : 645.369
    Hall A energy (halla_MeV) : 646.059
    Hall C energy (hallc_MeV) : 1876.34
    Delta(E)/E width (MV_AI_DXWID) : 0.743947
    IPM1C12.XPOS : -1.26498
    IPM1H04A.XPOS : -1.08586
    IPM1H04A.YPOS : -0.103929
    IPM1H04B.XPOS : -0.997299
    IPM1H04B.YPOS : -0.00219834
    Left Arm Collimator : 0.871387
    HacL_HPE1313A:0_Ch58 : -0.319336
    HacL_HPE1313A:0_Ch55 : 22.7539
    HacL_HPE1313A:0_Ch54 : -0.280762
    SLI data valid? : Yes
    SLI horiz size mm : 0.293674
    SLI Energy spread *10^5 : 5.4384
    SLI x position : 1.40124
    SLI vert. size mm : 0.107239
    SLI y position : 1.72019