Privacy and Security Notice
Main INDEX
Monthly INDEX
PREV
NEXT
User name a-onl
Log entry time 22:18:28 on November 29, 2007
Entry number 217163
keyword=End_of_Run_3048
****************************
Run Number: 3048
End of Run Comment:
Run_type=Production,target_type=Dummy 10 cm,beam_e0=0.6458457,beam_raster=on,leftarm_p=0.12418,leftarm_theta=120,leftarm_colli=out,rightarm_p=0.15321,rightarm_theta=120,rightarm_colli=out,comment_text=
PRESCALE FACTORS:ps1=16777212 ps2=16777215 ps3=1 ps4=2 ps5=65535 ps6=65535 ps7=9999 ps8=65535
EVENTS : 284363
TIME : 4.891 mins
DEAD TIME: 16.76%
TRIGGER RATES: PRES/REAL
T3:1000.5/1000.5 Hz T4:163.6/327.1 Hz T5: 0.0/0.0 Hz T8: 0.0/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T3: 293620/293620 T4: 48005/96011 T5: 0/0 T8: 4/300525
AVERAGE CURRENT
BCM x1 : 43.7945uA BCM x3 : 43.8506uA BCM x10: 38.1247uA
APPROXIMATE BCM CHARGES (C)
BCM u1 : 0.01287 BCM u3 : 0.01287 BCM u10: 0.01113
BCM d1 : 0.01284 BCM d3 : 0.01287 BCM d10: 0.01125
****************************
End-of-run EPICS data for Run Number 3048 at Thu Nov 29 22:18:25 EST 2007
Wien angle : 12.3659
Half-wave plate (off=out) : IN
Left Arm D1 momentum : 0.12421
Left Arm arm angle : 120
Right Arm D1 momentum : 0.15319
Right Arm arm angle : 120
HALLA:p : 646.057
HALLA:dpp : 0.000246883
Tiefenbach Hall A energy : 646.057
Left Arm Top VDC Current : 3.27148
Left Arm Bottom VDC Current : 0.634766
Left Arm Q1 momentum : 0.124091
Left Arm Q1 power supply : 90.3639
Left Arm Q1 gauss meter : -0.007622
Left Arm Q2 gauss meter : 0.02832
Left Arm Q2 power supply current : 51.9892
Left Arm Q2 momentum : 0.123897
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 39.1642
Left Arm D1 momentum : 0.124154
Left Arm D1 NMR : 0.297378
Left Arm Q3 gauss meter : -0.02404
Left Arm Q3 power supply current : 47.018
Left Arm Q3 momentum : 0.124112
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 momentum : 0.152598
Right Arm Q1 power supply : 111.94
Right Arm Q1 gauss meter : -0.002901
Right Arm Q2 power supply current : 64.9202
Right Arm Q2 momentum : 0.152966
Right Arm Q2 gauss meter : 0.03461
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 50.2021
Right Arm D1 momentum : 0.15319
Right Arm D1 NMR : 0.504915
Right Arm Q3 power supply current : 60.0716
Right Arm Q3 momentum : 0.153196
Right Arm Q3 gauss meter : 0.02703
Right Arm Q3 power supply polarity : disabled
Average current of the two cavities : 49.295
Current on Unser monitor : 59.8632
Current on Upstream bcm : 49.3459
Current on Downstream bcm : 49.2442
Upstream Cavity Coefficient : 43.377
Downstream Cavity Coefficient : 42.913
Current on IBC0L02 (source) : 104.207
Hall C Current : 57.72
MBSY1c magnet current (amp) : 26.4309
MBSY1c Bdl : 161063
Hall A momentum (Tiefenbach) (HALLA:p) : 646.059
Hall A momentum orbit correction (dpp) : 0.000249583
Hall A setup momentum (MMSHLAE) : 645.369
Hall A energy (halla_MeV) : 646.059
Hall C energy (hallc_MeV) : 1876.33
Delta(E)/E width (MV_AI_DXWID) : 0.796326
IPM1C12.XPOS : -1.25816
IPM1H04A.XPOS : -1.09748
IPM1H04A.YPOS : -0.0944439
IPM1H04B.XPOS : -1.00872
IPM1H04B.YPOS : 0.000368893
Left Arm Collimator : 0.871338
HacL_HPE1313A:0_Ch58 : -0.319824
HacL_HPE1313A:0_Ch55 : 22.7051
HacL_HPE1313A:0_Ch54 : -0.280762
SLI data valid? : Yes
SLI horiz size mm : 0.297296
SLI Energy spread *10^5 : 5.50549
SLI x position : 1.43106
SLI vert. size mm : 0.105557
SLI y position : 1.7277