Run Number: 3051
End of Run Comment:
Run_type=Production,target_type=Iron 50 degs Right,beam_e0=0.6458457,beam_raster=on,leftarm_p=0.12418,leftarm_theta=120,leftarm_colli=out,rightarm_p=0.15321,rightarm_theta=120,rightarm_colli=out,comment_text=
PRESCALE FACTORS:ps1=16777212 ps2=16777215 ps3=1 ps4=8 ps5=65535 ps6=65535 ps7=9999 ps8=65535
EVENTS : 219778
TIME : 10.078 mins
DEAD TIME: 5.75%
TRIGGER RATES: PRES/REAL
T3:364.0/364.0 Hz T4:21.6/173.1 Hz T5: 0.0/0.0 Hz T8: 0.0/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T3: 220127/220127 T4: 13083/104669 T5: 0/0 T8: 9/619203
AVERAGE CURRENT
BCM x1 : 49.7844uA BCM x3 : 49.8567uA BCM x10: 43.3243uA
APPROXIMATE BCM CHARGES (C)
BCM u1 : 0.03014 BCM u3 : 0.03014 BCM u10: 0.02599
BCM d1 : 0.03006 BCM d3 : 0.03015 BCM d10: 0.0264
****************************
End-of-run EPICS data for Run Number 3051 at Fri Nov 30 02:23:20 EST 2007
Wien angle : 12.3659
Half-wave plate (off=out) : IN
Left Arm D1 momentum : 0.147872
Left Arm arm angle : 120
Right Arm D1 momentum : 0.142779
Right Arm arm angle : 120
HALLA:p : 645.874
HALLA:dpp : -3.6906e-05
Tiefenbach Hall A energy : 645.874
Left Arm Top VDC Current : 0.927734
Left Arm Bottom VDC Current : -0.78125
Left Arm Q1 momentum : 0.147857
Left Arm Q1 power supply : 109.59
Left Arm Q1 gauss meter : 0.009757
Left Arm Q2 gauss meter : -0.03341
Left Arm Q2 power supply current : 62.1558
Left Arm Q2 momentum : 0.147755
Left Arm Q2 power supply polarity : enabled
Left Arm D1 power supply current : 49.2746
Left Arm D1 momentum : 0.147872
Left Arm D1 NMR : 0.399375
Left Arm Q3 gauss meter : 0.03035
Left Arm Q3 power supply current : 56.9729
Left Arm Q3 momentum : 0.148079
Left Arm Q3 power supply polarity : enabled
Right Arm Q1 momentum : 0.144115
Right Arm Q1 power supply : 104.463
Right Arm Q1 gauss meter : -0.00274
Right Arm Q2 power supply current : 60.5089
Right Arm Q2 momentum : 0.142845
Right Arm Q2 gauss meter : 0.0323
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 47.3244
Right Arm D1 momentum : 0.142779
Right Arm D1 NMR : 0.456672
Right Arm Q3 power supply current : 55.9739
Right Arm Q3 momentum : 0.142953
Right Arm Q3 gauss meter : 0.02521
Right Arm Q3 power supply polarity : disabled
Average current of the two cavities : 50.874
Current on Unser monitor : 62.2587
Current on Upstream bcm : 50.9596
Current on Downstream bcm : 50.7884
Upstream Cavity Coefficient : 43.377
Downstream Cavity Coefficient : 42.913
Current on IBC0L02 (source) : 130.436
Hall C Current : 80.34
MBSY1c magnet current (amp) : 26.4309
MBSY1c Bdl : 161063
Hall A momentum (Tiefenbach) (HALLA:p) : 645.867
Hall A momentum orbit correction (dpp) : -4.69483e-05
Hall A setup momentum (MMSHLAE) : 645.369
Hall A energy (halla_MeV) : 645.867
Hall C energy (hallc_MeV) : 1876.33
Delta(E)/E width (MV_AI_DXWID) : 1.00012
IPM1C12.XPOS : -0.0547351
IPM1H04A.XPOS : -1.10401
IPM1H04A.YPOS : -0.11305
IPM1H04B.XPOS : -1.00668
IPM1H04B.YPOS : -0.0116048
Left Arm Collimator : 0.871387
HacL_HPE1313A:0_Ch58 : -0.320801
HacL_HPE1313A:0_Ch55 : 22.6074
HacL_HPE1313A:0_Ch54 : -0.280762
SLI data valid? : Yes
SLI horiz size mm : 0.309264
SLI Energy spread *10^5 : 5.72712
SLI x position : 1.13292
SLI vert. size mm : 0.107452
SLI y position : 1.73521