Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 02:44:24 on November 30, 2007

    Entry number 217184

    keyword=End_of_Run_3052
    ****************************
     Run Number: 3052
     End of Run Comment:
    Run_type=Production,target_type=LH2 15cm + Pb foil Loop3,beam_e0=0.6458457,beam_raster=on,leftarm_p=0.12418,leftarm_theta=120,leftarm_colli=out,rightarm_p=0.15321,rightarm_theta=120,rightarm_colli=out,comment_text=
     
    
    PRESCALE FACTORS:ps1=16777212   ps2=16777215   ps3=6   ps4=35   ps5=65535   ps6=65535   ps7=9999   ps8=65535   
    
    EVENTS   : 591810       
    TIME     : 9.951 mins  
    
    DEAD TIME:   1.37%      
    
    TRIGGER RATES:   PRES/REAL
    T3:984.0/5903.8 Hz   T4:21.0/734.3 Hz   T5: 0.0/0.0  Hz   T8: 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T3: 587478/3524869  T4:  12525/438388   T5:      0/0        T8:      9/611382   
    
    AVERAGE CURRENT
    BCM x1 : 50.0914uA  BCM x3 : 50.1638uA  BCM x10: 43.4373uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 : 0.02995        BCM u3 : 0.02994        BCM u10: 0.02573        
    
    BCM d1 : 0.02987        BCM d3 : 0.02996        BCM d10: 0.02614        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 3052 at Fri Nov 30 02:44:21 EST 2007
    
    Wien angle : 12.3659
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.147872
    Left Arm arm angle : 120
    Right Arm D1 momentum : 0.142834
    Right Arm arm angle : 120
    HALLA:p : 645.862
    HALLA:dpp : -5.47418e-05
    Tiefenbach Hall A energy : 645.862
    Left Arm Top VDC Current : 3.41797
    Left Arm Bottom VDC Current : -1.9043
    Left Arm Q1 momentum : 0.147998
    Left Arm Q1 power supply : 109.537
    Left Arm Q1 gauss meter : 0.009766
    Left Arm Q2 gauss meter : -0.03344
    Left Arm Q2 power supply current : 62.1554
    Left Arm Q2 momentum : 0.147887
    Left Arm Q2 power supply polarity : enabled
    Left Arm D1 power supply current : 49.2733
    Left Arm D1 momentum : 0.147872
    Left Arm D1 NMR : 0.173825
    Left Arm Q3 gauss meter : 0.03036
    Left Arm Q3 power supply current : 56.9727
    Left Arm Q3 momentum : 0.148079
    Left Arm Q3 power supply polarity : enabled
    Right Arm Q1 momentum : 0.142683
    Right Arm Q1 power supply : 104.143
    Right Arm Q1 gauss meter : -0.002708
    Right Arm Q2 power supply current : 60.5083
    Right Arm Q2 momentum : 0.142845
    Right Arm Q2 gauss meter : 0.03229
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 47.5171
    Right Arm D1 momentum : 0.142834
    Right Arm D1 NMR : 0.163596
    Right Arm Q3 power supply current : 55.9733
    Right Arm Q3 momentum : 0.142785
    Right Arm Q3 gauss meter : 0.02521
    Right Arm Q3 power supply polarity : disabled
    Average current of the two cavities : 49.427
    Current on Unser monitor : 61.0826
    Current on Upstream bcm : 49.4839
    Current on Downstream bcm : 49.3701
    Upstream Cavity Coefficient : 43.377
    Downstream Cavity Coefficient : 42.913
    Current on IBC0L02 (source) : 129.419
    Hall C Current : 81.84
    MBSY1c magnet current (amp) : 26.4309
    MBSY1c Bdl : 161063
    Hall A momentum (Tiefenbach) (HALLA:p) : 645.863
    Hall A momentum orbit correction (dpp) : -5.28003e-05
    Hall A setup momentum (MMSHLAE) : 645.369
    Hall A energy (halla_MeV) : 645.864
    Hall C energy (hallc_MeV) : 1876.33
    Delta(E)/E width (MV_AI_DXWID) : 0.950836
    IPM1C12.XPOS : -0.0306467
    IPM1H04A.XPOS : -1.09633
    IPM1H04A.YPOS : -0.0897241
    IPM1H04B.XPOS : -1.00311
    IPM1H04B.YPOS : -0.00348246
    Left Arm Collimator : 0.871387
    HacL_HPE1313A:0_Ch58 : -0.320312
    HacL_HPE1313A:0_Ch55 : 22.6562
    HacL_HPE1313A:0_Ch54 : -0.28125
    SLI data valid? : Yes
    SLI horiz size mm : 0.306786
    SLI Energy spread *10^5 : 5.68123
    SLI x position : 1.13292
    SLI vert. size mm : 0.101623
    SLI y position : 1.7277