Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 02:51:12 on November 30, 2007

    Entry number 217186

    keyword=Start_Run_3053,Run_type=Production,target_type=LH2 15cm Loop3,beam_e0=0.6458457,beam_raster=on,leftarm_p=0.12418,leftarm_theta=120,leftarm_colli=out,rightarm_p=0.15321,rightarm_theta=120,rightarm_colli=out,comment_text=
    Run Timestamp:       Fri Nov 30 02:49:50 EST 2007
    Beginning-of-run EPICS data for Run Number 3053 at Fri Nov 30 02:50:17 EST 2007
    
    
    
    Run_type=Production
    target_type=LH2 15cm Loop3
    beam_e0=0.6458457
    beam_raster=on
    leftarm_p=0.12418
    leftarm_theta=120
    leftarm_colli=out
    rightarm_p=0.15321
    rightarm_theta=120
    rightarm_colli=out
    comment_text=
    
    
    ; Left Spectrometer DAQ on adaql2/a-onl account
    ; Prescale factors (integer), downloaded each run at prestart.
    ; Do NOT put spaces in string, NOR add 2nd string. (REALLY!!!)
    ; Change this file only in-between runs.
    ; Maxima: (2^24)-1 = 16,777,215 for T1-T4 and 65535 for T5-T8
    ; The default factor is essentially infinite.
    ; T3 = Left arm trigger.
    ; T4 = Left arm efficiency trigger
    ; T8 = 1024 Hz pulser
    ; String should be one line, no spaces, ending in carriage return
    
    ps1=16777212,ps2=16777215,ps3=4,ps4=15,ps5=65535,ps6=65535,ps7=9999,ps8=65535
    
    Left Arm Q1 momentum : 0.147842
    Left Arm Q1 power supply : 109.537
    Left Arm Q1 gauss meter : 0.00976
    Left Arm Q2 power supply current : 62.1554
    Left Arm Q2 momentum : 0.147623
    Left Arm Q2 gauss meter : -0.0334
    Left Arm Q2 power supply polarity : enabled
    Left Arm D1 power supply current : 49.2738
    Left Arm D1 momentum : 0.147928
    Left Arm D1 NMR : 0.286819
    Left Arm Q3 power supply current : 56.9727
    Left Arm Q3 momentum : 0.148029
    Left Arm Q3 gauss meter : 0.03035
    Left Arm Q3 power supply polarity : enabled
    Left Arm B Field Hall Probe (D-G) : 0.05313
    Right Arm Q1 momentum : 0.14316
    Right Arm Q1 power supply : 104.25
    Right Arm Q1 gauss meter : -0.002706
    Right Arm Q2 power supply current : 60.5083
    Right Arm Q2 momentum : 0.142756
    Right Arm Q2 gauss meter : 0.03228
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 47.5841
    Right Arm D1 momentum : 0.142834
    Right Arm D1 NMR : 0.203442
    Right Arm Q3 power supply current : 55.9739
    Right Arm Q3 momentum : 0.142841
    Right Arm Q3 gauss meter : 0.02524
    Right Arm Q3 power supply polarity : disabled
    Right Arm B Field Hall Probe (D-G) : -0.05241
    Left Arm Top VDC Current : -0.292969
    Left Arm Bottom VDC Current : -2.19727
    Left Arm Top VDC voltage : 3.99805
    Left Arm Bottom VDC voltage : 4
    Right Arm Top VDC Current : -0.146484
    Right Arm Bottom VDC Current : 1.51367
    Right Arm Top VDC voltage : 4.00049
    Right Arm Bottom VDC voltage : 3.99512
    -----
    Average current of the two cavities : 50.3547
    Current on Unser monitor : 62.1291
    Current on Upstream bcm : 50.4055
    Current on Downstream bcm : 50.3039
    Upstream Cavity Coefficient : 43.377
    Downstream Cavity Coefficient : 42.913
    Current on IBC0L02 (source) : 129.986
    Hall C Current : 80.19
    Hall A momentum (Tiefenbach) (HALLA:p) : 645.865
    Hall A momentum orbit correction (dpp) : -5.03542e-05
    Hall A setup momentum (MMSHLAE) : 645.369
    Hall A energy (halla_MeV) : 645.865
    Hall C energy (hallc_MeV) : 1876.34
    Delta(E)/E width (MV_AI_DXWID) : 0.960426
    MBSY1c magnet current (amp) : 26.4309
    MBSY1c Bdl : 161063
    Arc1 dp/p : 0
    Arc2 dp/p : 0
    Left Arm Collimator : 0.871484
    HacL_HPE1313A:0_Ch58 : -0.319824
    HacL_HPE1313A:0_Ch55 : 22.6562
    HacL_HPE1313A:0_Ch54 : -0.280762
    Left Arm Angle Floor Angle : 120
    Left Arm Angle Vernier : 31.1
    Left Arm Scattering Angle : 120
    Right Arm Arm Collimator : 0.863135
    HacR_HPE1313A:0_Ch58 : -0.719238
    HacR_HPE1313A:0_Ch55 : 21.3867
    HacR_HPE1313A:0_Ch54 : -0.894531
    Right Arm Angle Floor Angle : 120
    Right Arm Angle Vernier : -34.2
    Right Arm Scattering Angle : 120
    -----
    IPM1C12.XPOS : -0.0409771
    IPM1C12.YPOS : 0.638077
    IPM1H04A.XPOS : -1.09689
    IPM1H04A.YPOS : -0.0894611
    IPM1H04B.XPOS : -0.999896
    IPM1H04B.YPOS : 0.00745493
    Survey X offset bpmA : -0.63
    Survey Y offset bpmA : -0.9
    Survey X offset bpmB : 0.77
    Survey Y offset bpmB : -1
    -----
    Wien angle : 12.3659
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien field : 8.1344
    Laser attenuation Hall A : 177
    Laser power Hall A : 100
    Half-wave plate (off=out) : IN
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : IN
    Target : L3 15cm
    fan frequency loop 1 : 60
    fan frequency loop 2 : 0
    fan frequency loop 3 : 60
    Encoder position : 1.63491e+07
    Target type : 1.63491e+07
    temperature loop 1(1) : 7
    temperature loop 1(2) : 6.99
    temperature loop 1(3) : 7.04
    Heat exchange He : 7.4
    temperature loop 3(1) : 18.63
    temperature loop 3(2) : 16.51
    temperature loop 3(3) : 18.98
    Heat exchange H2 : 18.5
    pressure loop He : 185.703
    pressure loop H2 before : 20.9979
    pressure loop H2 return : 21.3672
    HPH He loop 1 : 217.031
    HPH He loop 2 : 0.00766597
    HPH H2 loop 3 : 76.3186
    -----
    SLI data valid? : Yes
    SLI horiz size mm : 0.308312
    SLI Energy spread *10^5 : 5.70949
    SLI x position : 1.13292
    SLI vert. size mm : 0.0992836
    SLI y position : 1.7277
    CSR NaI 251-270
    CSR Slot13 ch0 : -1801.4
    CSR Slot13 ch1 : -2002.1
    CSR Slot13 ch2 : -2050.9
    CSR Slot13 ch3 : -2001
    CSR Slot13 ch4 : -1900.9
    CSR Slot13 ch5 : -2001.1
    CSR Slot13 ch6 : -1701.2
    CSR Slot13 ch7 : -1801.4
    CSR Slot13 ch8 : -1802.4
    CSR Slot13 ch9 : -1801.9
    CSR Slot13 ch10 : -1802
    CSR Slot13 ch11 : -1501.4
    CSR Slot14 ch0 : -1901
    CSR Slot14 ch1 : -1900.4
    CSR Slot14 ch2 : -2000.3
    CSR Slot14 ch3 : -2051
    CSR Slot14 ch4 : -2101.2
    CSR Slot14 ch5 : -2100.7
    CSR Slot14 ch6 : -2101.4
    CSR Slot14 ch7 : -2099.7
    CSR Slot14 ch8 : -2102
    CSR Slot14 ch9 : -1801.3
    CSR Slot14 ch10 : -821
    CSR Slot14 ch11 : -14.1
    Left S2 HV
    S2 Slot0 ch0 : -2335.9
    S2 Slot0 ch1 : -2202.4
    S2 Slot0 ch2 : -2153.5
    S2 Slot0 ch3 : -2211.9
    S2 Slot0 ch4 : -2425.8
    S2 Slot0 ch5 : -2197.2
    S2 Slot0 ch6 : -1940.7
    S2 Slot0 ch7 : -1867.1
    S2 Slot0 ch8 : -2036.6
    S2 Slot0 ch9 : -1880.5
    S2 Slot0 ch10 : -2060.7
    S2 Slot0 ch11 : -1857.2
    -----
    Left S1 HV
    S1 Slot1 ch0 : -1819.6
    S1 Slot1 ch1 : -1810.5
    S1 Slot1 ch2 : -1805.4
    S1 Slot1 ch3 : -1775.5
    S1 Slot1 ch4 : -1721.8
    S1 Slot1 ch5 : -1900.4
    S1 Slot1 ch6 : -1966.3
    S1 Slot1 ch7 : -1725.1
    S1 Slot1 ch8 : -1951.7
    S1 Slot1 ch9 : -1775.9
    S1 Slot1 ch10 : -1820.9
    S1 Slot1 ch11 : -1860.9
    -----
    Left Cerenkov HV
    GCER Slot2 ch0 : -1570.8
    GCER Slot2 ch1 : -1477.2
    GCER Slot2 ch2 : -1544.8
    GCER Slot2 ch3 : -1461.3
    GCER Slot2 ch4 : -1813.5
    GCER Slot2 ch5 : -1985.9
    GCER Slot2 ch6 : -1690.4
    GCER Slot2 ch7 : -1775
    GCER Slot2 ch8 : -2000.7
    GCER Slot2 ch9 : -1635.4
    GCER Slot2 ch10 : -15.7
    GCER Slot2 ch11 : -23.6
    -----
    Left Pion Rejector Layer 1 HV
    PRL1 Slot3 ch0 : -860.4
    PRL1 Slot3 ch1 : -784.5
    PRL1 Slot3 ch2 : -905.8
    PRL1 Slot3 ch3 : -980.5
    PRL1 Slot3 ch4 : -730.3
    PRL1 Slot3 ch5 : -811
    PRL1 Slot3 ch6 : -1081.3
    PRL1 Slot3 ch7 : -990.8
    PRL1 Slot3 ch8 : -810.5
    PRL1 Slot3 ch9 : -790.9
    PRL1 Slot3 ch10 : -829.5
    PRL1 Slot3 ch11 : -785.3
    PRL1 Slot4 ch0 : -870.8
    PRL1 Slot4 ch1 : -901.3
    PRL1 Slot4 ch2 : -750.8
    PRL1 Slot4 ch3 : -895.9
    PRL1 Slot4 ch4 : -921.7
    PRL1 Slot4 ch5 : -821.2
    PRL1 Slot4 ch6 : -836
    PRL1 Slot4 ch7 : -826.4
    PRL1 Slot4 ch8 : -1190.3
    PRL1 Slot4 ch9 : -991.4
    PRL1 Slot4 ch10 : -1030.9
    PRL1 Slot4 ch11 : -861.4
    PRL1 Slot5 ch0 : -1041.1
    PRL1 Slot5 ch1 : -871
    PRL1 Slot5 ch2 : -917
    PRL1 Slot5 ch3 : -735.8
    PRL1 Slot5 ch4 : -890.7
    PRL1 Slot5 ch5 : -810.3
    PRL1 Slot5 ch6 : -821.1
    PRL1 Slot5 ch7 : -895.6
    PRL1 Slot5 ch8 : -741.3
    PRL1 Slot5 ch9 : -840.6
    PRL1 Slot5 ch10 : -16.5
    PRL1 Slot5 ch11 : -25.6
    -----
    Left Pion Rejector Layer 2 HV
    PRL2 Slot9 ch0 : -920.5
    PRL2 Slot9 ch1 : -881.3
    PRL2 Slot9 ch2 : -800.1
    PRL2 Slot9 ch3 : -869.9
    PRL2 Slot9 ch4 : -810.1
    PRL2 Slot9 ch5 : -941.5
    PRL2 Slot9 ch6 : -851.5
    PRL2 Slot9 ch7 : -890.6
    PRL2 Slot9 ch8 : -811.4
    PRL2 Slot9 ch9 : -780.6
    PRL2 Slot9 ch10 : -821
    PRL2 Slot9 ch11 : -851.4
    PRL2 Slot10 ch0 : -756.5
    PRL2 Slot10 ch1 : -812.4
    PRL2 Slot10 ch2 : -871
    PRL2 Slot10 ch3 : -900.8
    PRL2 Slot10 ch4 : -880.7
    PRL2 Slot10 ch5 : -871
    PRL2 Slot10 ch6 : -816
    PRL2 Slot10 ch7 : -824.8
    PRL2 Slot10 ch8 : -760.3
    PRL2 Slot10 ch9 : -715.7
    PRL2 Slot10 ch10 : -911
    PRL2 Slot10 ch11 : -781.3
    PRL2 Slot11 ch0 : -1000.7
    PRL2 Slot11 ch1 : -900.4
    PRL2 Slot11 ch2 : -851.3
    PRL2 Slot11 ch3 : -1079.9
    PRL2 Slot11 ch4 : -1050.2
    PRL2 Slot11 ch5 : -800
    PRL2 Slot11 ch6 : -860.4
    PRL2 Slot11 ch7 : -1030.5
    PRL2 Slot11 ch8 : -912.1
    PRL2 Slot11 ch9 : -880.3
    PRL2 Slot11 ch10 : -12.9
    PRL2 Slot11 ch11 : -24.7
    -----
    0 -1852
    1 -1719
    2 -1772
    3 -1957
    4 -
    5 -1764
    6 -1822
    7 -1730
    8 -
    9 -1676
    10 -1835
    11 -1660
    12 -1972
    13 -1808
    14 -1773
    15 -1840
    16 -1765
    17 -1788
    18 -1765
    19 -
    20 -1785
    21 -1866
    22 -1764
    23 -2058
    24 -1914
    25 -1787
    26 -2018
    27 -1564
    28 -1964
    29 -1667
    30 -1667
    31 -1968
    32 -1978
    33 -1976
    34 -1974
    35 -1976
    36 -1974
    37 -1975
    38 -1874
    39 -1718
    40 -1873
    41 -1839
    42 -1974
    43 -1816
    44 -1570
    45 -1776
    46 -1773
    47 -1926
    48 -1772
    49 -1924
    50 -1870
    51 -1973
    52 -1971
    53 -
    54 -1775
    55 -1776
    56 -1974
    57 -1978
    58 -1671
    59 -1674
    60 -1669
    61 -1771
    62 -1976
    63 -1771
    64 -
    65 -1558
    66 -1515
    67 -1461
    68 -1458
    69 -
    70 -1561
    71 -
    72 -1761
    73 -1657
    74 -1758
    75 -1962
    76 -1756
    77 -1666
    78 -1914
    79 -1935
    80 -1918
    81 -1922
    82 -1887
    83 -1882
    84 -1882
    85 -1887
    86 -1886
    87 -2038
    88 -1931
    89 -1786
    90 -1966
    91 -1534
    92 -1531
    93 -
    94 -1634
    95 -1738
    96 -1546
    97 -1552
    98 -2060
    99 -1657
    100 -1956
    101 -1860
    102 -1758
    103 -1956
    104 -1847
    105 -1754
    106 -1949
    107 -1949
    108 -1955
    109 -1850
    110 -1748
    111 -1750
    112 -1940
    113 -1935
    114 -2035
    115 -1886
    116 -2038
    117 -1635
    118 -1734
    119 -1738
    120 -1938
    121 -1990
    122 -1735
    123 -1838
    124 -1842
    125 -1936
    126 -1636
    127 -1936
    128 -1615
    129 -1474
    130 -1705
    131 -1680
    132 -1754
    133 -1918
    134 -1569
    135 -1482
    136 -1479
    137 -1640
    138 -1545
    139 -1599
    140 -1640
    141 -1689
    142 -1712
    143 -1594
    144 -1942
    145 -1942
    146 -1789
    147 -1839
    148 -1938
    149 -1642
    150 -1642
    151 -1641
    152 -
    153 -1438
    154 -1933
    155 -1834
    156 -1839
    157 -1539
    158 -1738
    159 -1892
    160 -1855
    161 -1947
    162 -1940
    163 -1946
    164 -1946
    165 -1645
    166 -1841
    167 -1953
    168 -1545
    169 -2047
    170 -1847
    171 -1698
    172 -1949
    173 -1746
    174 -2051
    175 -1592
    176 -1594
    177 -1971
    178 -2034
    179 -1978
    180 -1657
    181 -2086
    182 -1978
    183 -1667
    184 -1962
    185 -1668
    186 -1864
    187 -1456
    188 -1616
    189 -1717
    190 -1715
    191 -1729
    192 -1734
    193 -1734
    194 -2032
    195 -1839
    196 -1526
    197 -1428
    198 -1782
    199 -1586
    200 -1630
    201 -1932
    202 -2027
    203 -1734
    204 -1931
    205 -1730
    206 -1735
    207 -1534
    208 -1833
    209 -1723
    210 -1530
    211 -1430
    212 -1728
    213 -1732
    214 -1634
    215 -1530
    216 -1625
    217 -1730
    218 -1530
    219 -1631
    220 -1681
    221 -1530
    222 -1980
    223 -2132
    224 -1977
    225 -2050
    226 -1952
    227 -1826
    228 -1819
    229 -1922
    230 -1922
    231 -1954
    232 -2022
    233 -2026
    234 -1450
    235 -1922
    236 -1620
    237 -1827
    238 -1828
    239 -1825
    240 -1561
    241 -1956
    242 -1858
    243 -1859
    244 -1858
    245 -1663
    246 -1660
    247 -1580
    248 -1818
    249 -1818
    250 -1941
    251 -1761
    252 -1658
    253 -1861
    254 -1658
    255 -1648