    Log entry time 02:55:14 on November 30, 2007

    Entry number 217187

    keyword=End_of_Run_21289
    ****************************
     Run Number: 21289
     End of Run Comment:
    Run_type=Production,target_type=LH2 15cm Loop3,beam_e0=0.6458457,beam_raster=on,beam_halfwaveplate=out,leftarm_p=0.12418,leftarm_theta=120,leftarm_colli=out,rightarm_p=0.15321,rightarm_theta=120,rightarm_colli=out,comment_text=
     
    
    PRESCALE FACTORS:ps1=1   ps2=12   ps3=16777215   ps4=16777215   ps5=65535   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS   : 333273       
    TIME     : 5.187 mins  
    
    DEAD TIME:  15.30%      
    
    TRIGGER RATES:   PRES/REAL
    T1:1243.6/1243.6 Hz   T2:20.9/250.9 Hz   T8: 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1: 386999/386999   T2:   6508/78096    T8:      4/318671   
    
    AVERAGE CURRENT
    BCM x1 : 50.3766uA  BCM x3 : 79.4907uA  BCM x10: 21.9657uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 : 0.01571        BCM u3 : 0.0157         BCM u10: 5.331E-05      
    
    BCM d1 : 0.01565        BCM d3 : 0.03378        BCM d10: 0.01362        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 21289 at Fri Nov 30 02:55:11 EST 2007
    
    Wien angle : 12.3659
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.147928
    Left Arm arm angle : 120
    Right Arm D1 momentum : 0.142861
    Right Arm arm angle : 120
    HALLA:p : 645.865
    HALLA:dpp : -5.05425e-05
    Tiefenbach Hall A energy : 645.865
    Left Arm Top VDC Current : 0.0488281
    Left Arm Bottom VDC Current : 3.61328
    Left Arm Q1 momentum : 0.147857
    Left Arm Q1 power supply : 109.537
    Left Arm Q1 gauss meter : 0.009763
    Left Arm Q2 gauss meter : -0.03348
    Left Arm Q2 power supply current : 62.156
    Left Arm Q2 momentum : 0.147799
    Left Arm Q2 power supply polarity : enabled
    Left Arm D1 power supply current : 49.275
    Left Arm D1 momentum : 0.147928
    Left Arm D1 NMR : 0.159448
    Left Arm Q3 gauss meter : 0.03036
    Left Arm Q3 power supply current : 56.9735
    Left Arm Q3 momentum : 0.148079
    Left Arm Q3 power supply polarity : enabled
    Right Arm Q1 momentum : 0.142365
    Right Arm Q1 power supply : 104.089
    Right Arm Q1 gauss meter : -0.002696
    Right Arm Q2 power supply current : 60.5088
    Right Arm Q2 momentum : 0.1428
    Right Arm Q2 gauss meter : 0.03228
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 47.5922
    Right Arm D1 momentum : 0.142861
    Right Arm D1 NMR : 0.20528
    Right Arm Q3 power supply current : 55.9732
    Right Arm Q3 momentum : 0.142841
    Right Arm Q3 gauss meter : 0.02523
    Right Arm Q3 power supply polarity : disabled
    Average current of the two cavities : 50.1676
    Current on Unser monitor : 61.9875
    Current on Upstream bcm : 50.2515
    Current on Downstream bcm : 50.0836
    Upstream Cavity Coefficient : 43.377
    Downstream Cavity Coefficient : 42.913
    Current on IBC0L02 (source) : 129.299
    Hall C Current : 80.04
    MBSY1c magnet current (amp) : 26.4309
    MBSY1c Bdl : 161063
    Hall A momentum (Tiefenbach) (HALLA:p) : 645.864
    Hall A momentum orbit correction (dpp) : -5.2635e-05
    Hall A setup momentum (MMSHLAE) : 645.369
    Hall A energy (halla_MeV) : 645.864
    Hall C energy (hallc_MeV) : 1876.34
    Delta(E)/E width (MV_AI_DXWID) : 0.928425
    IPM1C12.XPOS : -0.0920699
    IPM1H04A.XPOS : -1.10523
    IPM1H04A.YPOS : -0.0792564
    IPM1H04B.XPOS : -1.01049
    IPM1H04B.YPOS : -0.00500584
    Left Arm Collimator : 0.871387
    HacL_HPE1313A:0_Ch58 : -0.320312
    HacL_HPE1313A:0_Ch55 : 22.7051
    HacL_HPE1313A:0_Ch54 : -0.280762
    SLI data valid? : Yes
    SLI horiz size mm : 0.314084
    SLI Energy spread *10^5 : 5.81637
    SLI x position : 1.13292
    SLI vert. size mm : 0.102657
    SLI y position : 1.72019