    keyword=End_of_Run_21290
    ****************************
     Run Number: 21290
     End of Run Comment:
    Run_type=Production,target_type=4He 10cm Loop1 High Pressure,beam_e0=0.6458457,beam_raster=on,beam_halfwaveplate=out,leftarm_p=0.12418,leftarm_theta=120,leftarm_colli=out,rightarm_p=0.15321,rightarm_theta=120,rightarm_colli=out,comment_text=
     
    
    PRESCALE FACTORS:ps1=3   ps2=15   ps3=16777215   ps4=16777215   ps5=65535   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS   : 294246       
    TIME     : 4.981 mins  
    
    DEAD TIME:   4.65%      
    
    TRIGGER RATES:   PRES/REAL
    T1:1016.0/3047.9 Hz   T2:16.6/248.4 Hz   T8: 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1: 303657/910973   T2:   4949/74235    T8:      4/306063   
    
    AVERAGE CURRENT
    BCM x1 : 43.8110uA  BCM x3 : 67.7519uA  BCM x10: 19.1824uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 : 0.01312        BCM u3 : 0.01311        BCM u10: 2.445E-05      
    
    BCM d1 : 0.01307        BCM d3 : 0.02739        BCM d10: 0.01144        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 21290 at Fri Nov 30 03:09:28 EST 2007
    
    Wien angle : 12.3659
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.147928
    Left Arm arm angle : 120
    Right Arm D1 momentum : 0.142807
    Right Arm arm angle : 120
    HALLA:p : 645.833
    HALLA:dpp : -0.000100287
    Tiefenbach Hall A energy : 645.833
    Left Arm Top VDC Current : -0.0488281
    Left Arm Bottom VDC Current : -2.14844
    Left Arm Q1 momentum : 0.14792
    Left Arm Q1 power supply : 109.537
    Left Arm Q1 gauss meter : 0.009763
    Left Arm Q2 gauss meter : -0.03342
    Left Arm Q2 power supply current : 62.1559
    Left Arm Q2 momentum : 0.147579
    Left Arm Q2 power supply polarity : enabled
    Left Arm D1 power supply current : 49.274
    Left Arm D1 momentum : 0.147872
    Left Arm D1 NMR : 0.283103
    Left Arm Q3 gauss meter : 0.03036
    Left Arm Q3 power supply current : 56.9739
    Left Arm Q3 momentum : 0.148079
    Left Arm Q3 power supply polarity : enabled
    Right Arm Q1 momentum : 0.143319
    Right Arm Q1 power supply : 104.356
    Right Arm Q1 gauss meter : -0.002723
    Right Arm Q2 power supply current : 60.5082
    Right Arm Q2 momentum : 0.1428
    Right Arm Q2 gauss meter : 0.03229
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 47.7225
    Right Arm D1 momentum : 0.142807
    Right Arm D1 NMR : 0.163903
    Right Arm Q3 power supply current : 55.9739
    Right Arm Q3 momentum : 0.142785
    Right Arm Q3 gauss meter : 0.02524
    Right Arm Q3 power supply polarity : disabled
    Average current of the two cavities : 49.9162
    Current on Unser monitor : 60.7745
    Current on Upstream bcm : 49.9937
    Current on Downstream bcm : 49.8387
    Upstream Cavity Coefficient : 43.377
    Downstream Cavity Coefficient : 42.913
    Current on IBC0L02 (source) : 128.483
    Hall C Current : 80.55
    MBSY1c magnet current (amp) : 26.4309
    MBSY1c Bdl : 161063
    Hall A momentum (Tiefenbach) (HALLA:p) : 645.833
    Hall A momentum orbit correction (dpp) : -9.91226e-05
    Hall A setup momentum (MMSHLAE) : 645.369
    Hall A energy (halla_MeV) : 645.834
    Hall C energy (hallc_MeV) : 1876.35
    Delta(E)/E width (MV_AI_DXWID) : 0.859986
    IPM1C12.XPOS : -0.0951853
    IPM1H04A.XPOS : -1.11131
    IPM1H04A.YPOS : -0.0899326
    IPM1H04B.XPOS : -1.0177
    IPM1H04B.YPOS : 0.00452131
    Left Arm Collimator : 0.871387
    HacL_HPE1313A:0_Ch58 : -0.319824
    HacL_HPE1313A:0_Ch55 : 22.5586
    HacL_HPE1313A:0_Ch54 : -0.28125
    SLI data valid? : Yes
    SLI horiz size mm : 0.305952
    SLI Energy spread *10^5 : 5.66578
    SLI x position : 1.13292
    SLI vert. size mm : 0.110653
    SLI y position : 1.72019