Run Number: 3055
End of Run Comment:
Run_type=Production,target_type=4He 10cm Loop1 High Pressure,beam_e0=0.6458457,beam_raster=on,leftarm_p=0.12418,leftarm_theta=120,leftarm_colli=out,rightarm_p=0.15321,rightarm_theta=120,rightarm_colli=out,comment_text=
PRESCALE FACTORS:ps1=16777212 ps2=16777215 ps3=2 ps4=15 ps5=65535 ps6=65535 ps7=9999 ps8=65535
EVENTS : 313154
TIME : 5.019 mins
DEAD TIME: 5.16%
TRIGGER RATES: PRES/REAL
T3:1073.8/2147.5 Hz T4:22.7/340.5 Hz T5: 0.0/0.0 Hz T8: 0.0/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T3: 323366/646732 T4: 6835/102531 T5: 0/0 T8: 4/308383
AVERAGE CURRENT
BCM x1 : 49.6024uA BCM x3 : 49.7039uA BCM x10: 43.2878uA
APPROXIMATE BCM CHARGES (C)
BCM u1 : 0.01496 BCM u3 : 0.01496 BCM u10: 0.01293
BCM d1 : 0.01491 BCM d3 : 0.01497 BCM d10: 0.01315
****************************
End-of-run EPICS data for Run Number 3055 at Fri Nov 30 03:33:18 EST 2007
Wien angle : 12.3659
Half-wave plate (off=out) : IN
Left Arm D1 momentum : 0.133118
Left Arm arm angle : 120
Right Arm D1 momentum : 0.134031
Right Arm arm angle : 120
HALLA:p : 645.871
HALLA:dpp : -4.0552e-05
Tiefenbach Hall A energy : 645.872
Left Arm Top VDC Current : 4.3457
Left Arm Bottom VDC Current : 3.4668
Left Arm Q1 momentum : 0.132915
Left Arm Q1 power supply : 98.3215
Left Arm Q1 gauss meter : 0.008808
Left Arm Q2 gauss meter : -0.03009
Left Arm Q2 power supply current : 55.7528
Left Arm Q2 momentum : 0.132888
Left Arm Q2 power supply polarity : enabled
Left Arm D1 power supply current : 44.3079
Left Arm D1 momentum : 0.133118
Left Arm D1 NMR : 0.16548
Left Arm Q3 gauss meter : 0.02736
Left Arm Q3 power supply current : 51.0358
Left Arm Q3 momentum : 0.133068
Left Arm Q3 power supply polarity : enabled
Right Arm Q1 momentum : 0.12492
Right Arm Q1 power supply : 90.3105
Right Arm Q1 gauss meter : -0.00237
Right Arm Q2 power supply current : 52.3931
Right Arm Q2 momentum : 0.124105
Right Arm Q2 gauss meter : 0.02805
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 35.229
Right Arm D1 momentum : 0.133977
Right Arm D1 NMR : 0.166827
Right Arm Q3 power supply current : 48.4776
Right Arm Q3 momentum : 0.124202
Right Arm Q3 gauss meter : 0.02187
Right Arm Q3 power supply polarity : disabled
Average current of the two cavities : 49.3517
Current on Unser monitor : 60.4357
Current on Upstream bcm : 49.4049
Current on Downstream bcm : 49.2986
Upstream Cavity Coefficient : 43.377
Downstream Cavity Coefficient : 42.913
Current on IBC0L02 (source) : 128.129
Hall C Current : 79.71
MBSY1c magnet current (amp) : 26.4309
MBSY1c Bdl : 161063
Hall A momentum (Tiefenbach) (HALLA:p) : 645.87
Hall A momentum orbit correction (dpp) : -4.28335e-05
Hall A setup momentum (MMSHLAE) : 645.369
Hall A energy (halla_MeV) : 645.87
Hall C energy (hallc_MeV) : 1876.33
Delta(E)/E width (MV_AI_DXWID) : 0.934747
IPM1C12.XPOS : -0.0806446
IPM1H04A.XPOS : -1.05868
IPM1H04A.YPOS : -0.110238
IPM1H04B.XPOS : -0.958181
IPM1H04B.YPOS : -0.00446761
Left Arm Collimator : 0.871387
HacL_HPE1313A:0_Ch58 : -0.319824
HacL_HPE1313A:0_Ch55 : 22.6074
HacL_HPE1313A:0_Ch54 : -0.282227
SLI data valid? : Yes
SLI horiz size mm : 0.313675
SLI Energy spread *10^5 : 5.8088
SLI x position : 1.13292
SLI vert. size mm : 0.106506
SLI y position : 1.72019