Run Number: 3056
End of Run Comment:
Run_type=Production,target_type=LH2 15cm + Pb foil Loop3,beam_e0=0.6458457,beam_raster=on,leftarm_p=0.12418,leftarm_theta=120,leftarm_colli=out,rightarm_p=0.15321,rightarm_theta=120,rightarm_colli=out,comment_text=
PRESCALE FACTORS:ps1=16777212 ps2=16777215 ps3=4 ps4=30 ps5=65535 ps6=65535 ps7=9999 ps8=65535
EVENTS : 680176
TIME : 10.042 mins
DEAD TIME: 1.72%
TRIGGER RATES: PRES/REAL
T3:1125.8/4503.4 Hz T4:22.8/684.2 Hz T5: 0.0/0.0 Hz T8: 0.0/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T3: 678371/2713485 T4: 13741/412231 T5: 0/0 T8: 9/617005
AVERAGE CURRENT
BCM x1 : 50.3219uA BCM x3 : 50.4049uA BCM x10: 43.5681uA
APPROXIMATE BCM CHARGES (C)
BCM u1 : 0.03038 BCM u3 : 0.03038 BCM u10: 0.02603
BCM d1 : 0.03026 BCM d3 : 0.03037 BCM d10: 0.02648
****************************
End-of-run EPICS data for Run Number 3056 at Fri Nov 30 03:52:11 EST 2007
Wien angle : 12.3659
Half-wave plate (off=out) : IN
Left Arm D1 momentum : 0.133118
Left Arm arm angle : 120
Right Arm D1 momentum : 0.122285
Right Arm arm angle : 120
HALLA:p : 645.869
HALLA:dpp : -4.4324e-05
Tiefenbach Hall A energy : 645.869
Left Arm Top VDC Current : -0.634766
Left Arm Bottom VDC Current : -2.58789
Left Arm Q1 momentum : 0.133134
Left Arm Q1 power supply : 98.3215
Left Arm Q1 gauss meter : 0.008818
Left Arm Q2 gauss meter : -0.03007
Left Arm Q2 power supply current : 55.753
Left Arm Q2 momentum : 0.132932
Left Arm Q2 power supply polarity : enabled
Left Arm D1 power supply current : 44.3014
Left Arm D1 momentum : 0.133118
Left Arm D1 NMR : 0.233678
Left Arm Q3 gauss meter : 0.02736
Left Arm Q3 power supply current : 51.035
Left Arm Q3 momentum : 0.133068
Left Arm Q3 power supply polarity : enabled
Right Arm Q1 momentum : 0.124072
Right Arm Q1 power supply : 90.0435
Right Arm Q1 gauss meter : -0.00236
Right Arm Q2 power supply current : 52.3936
Right Arm Q2 momentum : 0.124061
Right Arm Q2 gauss meter : 0.02805
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 25.7646
Right Arm D1 momentum : 0.122312
Right Arm D1 NMR : 0.450856
Right Arm Q3 power supply current : 48.4771
Right Arm Q3 momentum : 0.124034
Right Arm Q3 gauss meter : 0.02186
Right Arm Q3 power supply polarity : disabled
Average current of the two cavities : 50.1788
Current on Unser monitor : 61.4465
Current on Upstream bcm : 50.1964
Current on Downstream bcm : 50.1613
Upstream Cavity Coefficient : 43.377
Downstream Cavity Coefficient : 42.913
Current on IBC0L02 (source) : 129.299
Hall C Current : 80.85
MBSY1c magnet current (amp) : 26.4309
MBSY1c Bdl : 161063
Hall A momentum (Tiefenbach) (HALLA:p) : 645.867
Hall A momentum orbit correction (dpp) : -4.71409e-05
Hall A setup momentum (MMSHLAE) : 645.369
Hall A energy (halla_MeV) : 645.867
Hall C energy (hallc_MeV) : 1876.33
Delta(E)/E width (MV_AI_DXWID) : 0.987947
IPM1C12.XPOS : -0.0473429
IPM1H04A.XPOS : -1.1131
IPM1H04A.YPOS : -0.0692603
IPM1H04B.XPOS : -1.01837
IPM1H04B.YPOS : 0.009242
Left Arm Collimator : 0.871338
HacL_HPE1313A:0_Ch58 : -0.320312
HacL_HPE1313A:0_Ch55 : 22.6074
HacL_HPE1313A:0_Ch54 : -0.281738
SLI data valid? : Yes
SLI horiz size mm : 0.306212
SLI Energy spread *10^5 : 5.67059
SLI x position : 1.13292
SLI vert. size mm : 0.112385
SLI y position : 1.72019