Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 04:17:56 on November 30, 2007

    Entry number 217206

    keyword=End_of_Run_3058
    ****************************
     Run Number: 3058
     End of Run Comment:
    Run_type=Production,target_type=Dummy 10 cm,beam_e0=0.6458457,beam_raster=on,leftarm_p=0.12418,leftarm_theta=120,leftarm_colli=out,rightarm_p=0.15321,rightarm_theta=120,rightarm_colli=out,comment_text=
     
    
    PRESCALE FACTORS:ps1=16777212   ps2=16777215   ps3=1   ps4=15   ps5=65535   ps6=65535   ps7=9999   ps8=65535   
    
    EVENTS   : 290262       
    TIME     : 6.119 mins  
    
    DEAD TIME:  11.78%      
    
    TRIGGER RATES:   PRES/REAL
    T3:871.9/871.9 Hz   T4:24.3/364.7 Hz   T5: 0.0/0.0  Hz   T8: 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T3: 320111/320111   T4:   8925/133881   T5:      0/0        T8:      5/375939   
    
    AVERAGE CURRENT
    BCM x1 : 50.6630uA  BCM x3 : 50.7275uA  BCM x10: 43.7102uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 : 0.01864        BCM u3 : 0.01864        BCM u10: 0.01591        
    
    BCM d1 : 0.01856        BCM d3 : 0.01861        BCM d10: 0.01619        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 3058 at Fri Nov 30 04:17:53 EST 2007
    
    Wien angle : 12.3659
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.133062
    Left Arm arm angle : 120
    Right Arm D1 momentum : 0.123675
    Right Arm arm angle : 120
    HALLA:p : 645.863
    HALLA:dpp : -5.35651e-05
    Tiefenbach Hall A energy : 645.863
    Left Arm Top VDC Current : -2.49023
    Left Arm Bottom VDC Current : 1.66016
    Left Arm Q1 momentum : 0.13315
    Left Arm Q1 power supply : 98.3215
    Left Arm Q1 gauss meter : 0.008819
    Left Arm Q2 gauss meter : -0.03013
    Left Arm Q2 power supply current : 55.7537
    Left Arm Q2 momentum : 0.133196
    Left Arm Q2 power supply polarity : enabled
    Left Arm D1 power supply current : 44.2959
    Left Arm D1 momentum : 0.133062
    Left Arm D1 NMR : 0.247561
    Left Arm Q3 gauss meter : 0.02736
    Left Arm Q3 power supply current : 51.0354
    Left Arm Q3 momentum : 0.133018
    Left Arm Q3 power supply polarity : enabled
    Right Arm Q1 momentum : 0.12508
    Right Arm Q1 power supply : 90.4173
    Right Arm Q1 gauss meter : -0.002379
    Right Arm Q2 power supply current : 52.3933
    Right Arm Q2 momentum : 0.124061
    Right Arm Q2 gauss meter : 0.02805
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 34.0893
    Right Arm D1 momentum : 0.123675
    Right Arm D1 NMR : 0.2752
    Right Arm Q3 power supply current : 48.4774
    Right Arm Q3 momentum : 0.124258
    Right Arm Q3 gauss meter : 0.0219
    Right Arm Q3 power supply polarity : disabled
    Average current of the two cavities : 50.3164
    Current on Unser monitor : 61.2548
    Current on Upstream bcm : 50.3916
    Current on Downstream bcm : 50.2411
    Upstream Cavity Coefficient : 43.377
    Downstream Cavity Coefficient : 42.913
    Current on IBC0L02 (source) : 128.972
    Hall C Current : 79.98
    MBSY1c magnet current (amp) : 26.4309
    MBSY1c Bdl : 161063
    Hall A momentum (Tiefenbach) (HALLA:p) : 645.853
    Hall A momentum orbit correction (dpp) : -6.84905e-05
    Hall A setup momentum (MMSHLAE) : 645.369
    Hall A energy (halla_MeV) : 645.853
    Hall C energy (hallc_MeV) : 1876.33
    Delta(E)/E width (MV_AI_DXWID) : 0.645393
    IPM1C12.XPOS : -0.0643272
    IPM1H04A.XPOS : -1.08246
    IPM1H04A.YPOS : -0.0994141
    IPM1H04B.XPOS : -0.985844
    IPM1H04B.YPOS : -0.0021795
    Left Arm Collimator : 0.871387
    HacL_HPE1313A:0_Ch58 : -0.319824
    HacL_HPE1313A:0_Ch55 : 22.6074
    HacL_HPE1313A:0_Ch54 : -0.281738
    SLI data valid? : Yes
    SLI horiz size mm : 0.311636
    SLI Energy spread *10^5 : 5.77103
    SLI x position : 1.13292
    SLI vert. size mm : 0.103887
    SLI y position : 1.7277