    Log entry time 04:45:16 on November 30, 2007

    Entry number 217212

    keyword=End_of_Run_21291
    ****************************
     Run Number: 21291
     End of Run Comment:
    Run_type=Production,target_type=Carbon 50 degs Right,beam_e0=0.6458457,beam_raster=on,beam_halfwaveplate=out,leftarm_p=0.12418,leftarm_theta=120,leftarm_colli=out,rightarm_p=0.15321,rightarm_theta=120,rightarm_colli=out,comment_text=
     
    
    PRESCALE FACTORS:ps1=1   ps2=2   ps3=16777215   ps4=16777215   ps5=65535   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS   : 152580       
    TIME     : 10.133 mins  
    
    DEAD TIME:   4.20%      
    
    TRIGGER RATES:   PRES/REAL
    T1:245.8/245.8 Hz   T2:16.2/32.4 Hz   T8: 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1: 149423/149423   T2:   9854/19708    T8:      9/622590   
    
    AVERAGE CURRENT
    BCM x1 : 49.5575uA  BCM x3 : 77.7090uA  BCM x10: 21.7134uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 : 0.03022        BCM u3 : 0.0302         BCM u10: -6.345E-06     
    
    BCM d1 : 0.03004        BCM d3 : 0.06429        BCM d10: 0.02641        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 21291 at Fri Nov 30 04:45:13 EST 2007
    
    Wien angle : 12.3659
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.133118
    Left Arm arm angle : 120
    Right Arm D1 momentum : 0.124002
    Right Arm arm angle : 120
    HALLA:p : 645.829
    HALLA:dpp : -0.000100538
    Tiefenbach Hall A energy : 645.833
    Left Arm Top VDC Current : -2.34375
    Left Arm Bottom VDC Current : 1.12305
    Left Arm Q1 momentum : 0.133072
    Left Arm Q1 power supply : 98.3215
    Left Arm Q1 gauss meter : 0.008814
    Left Arm Q2 gauss meter : -0.03007
    Left Arm Q2 power supply current : 55.7536
    Left Arm Q2 momentum : 0.132844
    Left Arm Q2 power supply polarity : enabled
    Left Arm D1 power supply current : 44.3063
    Left Arm D1 momentum : 0.13309
    Left Arm D1 NMR : 0.344163
    Left Arm Q3 gauss meter : 0.02736
    Left Arm Q3 power supply current : 51.0356
    Left Arm Q3 momentum : 0.133018
    Left Arm Q3 power supply polarity : enabled
    Right Arm Q1 momentum : 0.124337
    Right Arm Q1 power supply : 90.4707
    Right Arm Q1 gauss meter : -0.002365
    Right Arm Q2 power supply current : 52.393
    Right Arm Q2 momentum : 0.124017
    Right Arm Q2 gauss meter : 0.02804
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 36.6068
    Right Arm D1 momentum : 0.124002
    Right Arm D1 NMR : 0.205829
    Right Arm Q3 power supply current : 48.4774
    Right Arm Q3 momentum : 0.124034
    Right Arm Q3 gauss meter : 0.02186
    Right Arm Q3 power supply polarity : disabled
    Average current of the two cavities : 49.823
    Current on Unser monitor : 60.0537
    Current on Upstream bcm : 49.8766
    Current on Downstream bcm : 49.7695
    Upstream Cavity Coefficient : 43.377
    Downstream Cavity Coefficient : 42.913
    Current on IBC0L02 (source) : 128.203
    Hall C Current : 80.73
    MBSY1c magnet current (amp) : 26.4309
    MBSY1c Bdl : 161063
    Hall A momentum (Tiefenbach) (HALLA:p) : 645.833
    Hall A momentum orbit correction (dpp) : -0.000100538
    Hall A setup momentum (MMSHLAE) : 645.369
    Hall A energy (halla_MeV) : 645.833
    Hall C energy (hallc_MeV) : 1876.33
    Delta(E)/E width (MV_AI_DXWID) : 0.902722
    IPM1C12.XPOS : -0.0438201
    IPM1H04A.XPOS : -1.08948
    IPM1H04A.YPOS : -0.090272
    IPM1H04B.XPOS : -0.991193
    IPM1H04B.YPOS : 0.0153201
    Left Arm Collimator : 0.871338
    HacL_HPE1313A:0_Ch58 : -0.320312
    HacL_HPE1313A:0_Ch55 : 22.5586
    HacL_HPE1313A:0_Ch54 : -0.28125
    SLI data valid? : Yes
    SLI horiz size mm : 0.310833
    SLI Energy spread *10^5 : 5.75617
    SLI x position : 1.13292
    SLI vert. size mm : 0.104071
    SLI y position : 1.7277