Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name adev

    Log entry time 05:05:06 on November 30, 2007

    Entry number 217217

    keyword=End_of_Run_21292
    ****************************
     Run Number: 21292
     End of Run Comment:
    Run_type=Production,target_type=Iron 50 degs  Right,beam_e0=0.6458457,beam_raster=on,beam_halfwaveplate=out,leftarm_p=0.12418,leftarm_theta=120,leftarm_colli=out,rightarm_p=0.15321,rightarm_theta=120,rightarm_colli=out,comment_text=
     
    
    PRESCALE FACTORS:ps1=1   ps2=6   ps3=16777215   ps4=16777215   ps5=65535   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS   : 187921       
    TIME     : 10.225 mins  
    
    DEAD TIME:   4.88%      
    
    TRIGGER RATES:   PRES/REAL
    T1:300.3/300.3 Hz   T2:21.7/130.4 Hz   T8: 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1: 184231/184231   T2:  13335/80014    T8:      9/628220   
    
    AVERAGE CURRENT
    BCM x1 : 48.6860uA  BCM x3 : 77.4113uA  BCM x10: 21.2466uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 : 0.02996        BCM u3 : 0.02994        BCM u10: -3.071E-06     
    
    BCM d1 : 0.02978        BCM d3 : 0.06504        BCM d10: 0.02607        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 21292 at Fri Nov 30 05:05:03 EST 2007
    
    Wien angle : 12.3659
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.124015
    Left Arm arm angle : 120
    Right Arm D1 momentum : 0.124084
    Right Arm arm angle : 120
    HALLA:p : 645.863
    HALLA:dpp : -5.41886e-05
    Tiefenbach Hall A energy : 645.863
    Left Arm Top VDC Current : 4.58984
    Left Arm Bottom VDC Current : 3.95508
    Left Arm Q1 momentum : 0.124372
    Left Arm Q1 power supply : 91.5923
    Left Arm Q1 gauss meter : 0.008258
    Left Arm Q2 gauss meter : -0.02808
    Left Arm Q2 power supply current : 51.8242
    Left Arm Q2 momentum : 0.124179
    Left Arm Q2 power supply polarity : enabled
    Left Arm D1 power supply current : 41.246
    Left Arm D1 momentum : 0.124043
    Left Arm D1 NMR : 0.471518
    Left Arm Q3 gauss meter : 0.02559
    Left Arm Q3 power supply current : 47.5205
    Left Arm Q3 momentum : 0.124262
    Left Arm Q3 power supply polarity : enabled
    Right Arm Q1 momentum : 0.123383
    Right Arm Q1 power supply : 90.0969
    Right Arm Q1 gauss meter : -0.002347
    Right Arm Q2 power supply current : 52.393
    Right Arm Q2 momentum : 0.124017
    Right Arm Q2 gauss meter : 0.02804
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 37.6392
    Right Arm D1 momentum : 0.124084
    Right Arm D1 NMR : 0.249776
    Right Arm Q3 power supply current : 48.4779
    Right Arm Q3 momentum : 0.124146
    Right Arm Q3 gauss meter : 0.02186
    Right Arm Q3 power supply polarity : disabled
    Average current of the two cavities : 49.4062
    Current on Unser monitor : 60.9621
    Current on Upstream bcm : 49.4433
    Current on Downstream bcm : 49.3692
    Upstream Cavity Coefficient : 43.377
    Downstream Cavity Coefficient : 42.913
    Current on IBC0L02 (source) : 128.602
    Hall C Current : 79.74
    MBSY1c magnet current (amp) : 26.4309
    MBSY1c Bdl : 161063
    Hall A momentum (Tiefenbach) (HALLA:p) : 645.863
    Hall A momentum orbit correction (dpp) : -5.38497e-05
    Hall A setup momentum (MMSHLAE) : 645.369
    Hall A energy (halla_MeV) : 645.863
    Hall C energy (hallc_MeV) : 1876.33
    Delta(E)/E width (MV_AI_DXWID) : 0.85905
    IPM1C12.XPOS : -0.0598696
    IPM1H04A.XPOS : -1.09873
    IPM1H04A.YPOS : -0.0879592
    IPM1H04B.XPOS : -1.00036
    IPM1H04B.YPOS : 0.0246969
    Left Arm Collimator : 0.871387
    HacL_HPE1313A:0_Ch58 : -0.319824
    HacL_HPE1313A:0_Ch55 : 22.5586
    HacL_HPE1313A:0_Ch54 : -0.282227
    SLI data valid? : Yes
    SLI horiz size mm : 0.31687
    SLI Energy spread *10^5 : 5.86796
    SLI x position : 1.13292
    SLI vert. size mm : 0.0967171
    SLI y position : 1.72019