Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 05:05:09 on November 30, 2007

    Entry number 217218

    keyword=End_of_Run_3061
    ****************************
     Run Number: 3061
     End of Run Comment:
    Run_type=Production,target_type=Iron 50 degs  Right,beam_e0=0.6458457,beam_raster=on,leftarm_p=0.12418,leftarm_theta=120,leftarm_colli=out,rightarm_p=0.15321,rightarm_theta=120,rightarm_colli=out,comment_text=
     
    
    PRESCALE FACTORS:ps1=16777212   ps2=16777215   ps3=1   ps4=8   ps5=65535   ps6=65535   ps7=9999   ps8=65535   
    
    EVENTS   : 205065       
    TIME     : 10.225 mins  
    
    DEAD TIME:   5.56%      
    
    TRIGGER RATES:   PRES/REAL
    T3:332.8/332.8 Hz   T4:21.1/169.0 Hz   T5: 0.0/0.0  Hz   T8: 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T3: 204186/204186   T4:  12961/103691   T5:      0/0        T8:      9/628212   
    
    AVERAGE CURRENT
    BCM x1 : 48.6965uA  BCM x3 : 48.7212uA  BCM x10: 42.3244uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 : 0.02995        BCM u3 : 0.02995        BCM u10: 0.02575        
    
    BCM d1 : 0.0298         BCM d3 : 0.02983        BCM d10: 0.02618        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 3061 at Fri Nov 30 05:05:06 EST 2007
    
    Wien angle : 12.3659
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.124071
    Left Arm arm angle : 120
    Right Arm D1 momentum : 0.124056
    Right Arm arm angle : 120
    HALLA:p : 645.85
    HALLA:dpp : -7.37414e-05
    Tiefenbach Hall A energy : 645.85
    Left Arm Top VDC Current : 2.58789
    Left Arm Bottom VDC Current : 3.85742
    Left Arm Q1 momentum : 0.124419
    Left Arm Q1 power supply : 91.5389
    Left Arm Q1 gauss meter : 0.008258
    Left Arm Q2 gauss meter : -0.02806
    Left Arm Q2 power supply current : 51.8239
    Left Arm Q2 momentum : 0.124179
    Left Arm Q2 power supply polarity : enabled
    Left Arm D1 power supply current : 41.2455
    Left Arm D1 momentum : 0.124071
    Left Arm D1 NMR : 0.158382
    Left Arm Q3 gauss meter : 0.02559
    Left Arm Q3 power supply current : 47.5147
    Left Arm Q3 momentum : 0.124212
    Left Arm Q3 power supply polarity : enabled
    Right Arm Q1 momentum : 0.12333
    Right Arm Q1 power supply : 90.0969
    Right Arm Q1 gauss meter : -0.002346
    Right Arm Q2 power supply current : 52.3935
    Right Arm Q2 momentum : 0.123972
    Right Arm Q2 gauss meter : 0.02804
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 37.6386
    Right Arm D1 momentum : 0.124056
    Right Arm D1 NMR : 0.16342
    Right Arm Q3 power supply current : 48.4777
    Right Arm Q3 momentum : 0.124034
    Right Arm Q3 gauss meter : 0.02189
    Right Arm Q3 power supply polarity : disabled
    Average current of the two cavities : 49.3988
    Current on Unser monitor : 60.3487
    Current on Upstream bcm : 49.4171
    Current on Downstream bcm : 49.3805
    Upstream Cavity Coefficient : 43.377
    Downstream Cavity Coefficient : 42.913
    Current on IBC0L02 (source) : 127.32
    Hall C Current : 78.33
    MBSY1c magnet current (amp) : 26.4309
    MBSY1c Bdl : 161063
    Hall A momentum (Tiefenbach) (HALLA:p) : 645.854
    Hall A momentum orbit correction (dpp) : -6.69971e-05
    Hall A setup momentum (MMSHLAE) : 645.369
    Hall A energy (halla_MeV) : 645.854
    Hall C energy (hallc_MeV) : 1876.33
    Delta(E)/E width (MV_AI_DXWID) : 0.90609
    IPM1C12.XPOS : -0.0563176
    IPM1H04A.XPOS : -1.10667
    IPM1H04A.YPOS : -0.088406
    IPM1H04B.XPOS : -1.00515
    IPM1H04B.YPOS : -0.0257957
    Left Arm Collimator : 0.871387
    HacL_HPE1313A:0_Ch58 : -0.320312
    HacL_HPE1313A:0_Ch55 : 22.5098
    HacL_HPE1313A:0_Ch54 : -0.281738
    SLI data valid? : Yes
    SLI horiz size mm : 0.317095
    SLI Energy spread *10^5 : 5.87213
    SLI x position : 1.13292
    SLI vert. size mm : 0.0967171
    SLI y position : 1.7277