keyword=End_of_Run_3063
****************************
Run Number: 3063
End of Run Comment:
Run_type=Production,target_type=LH2 15cm Loop3,beam_e0=0.6458457,beam_raster=on,leftarm_p=0.12418,leftarm_theta=120,leftarm_colli=out,rightarm_p=0.15321,rightarm_theta=120,rightarm_colli=out,comment_text=
PRESCALE FACTORS:ps1=16777212 ps2=16777215 ps3=2 ps4=14 ps5=65535 ps6=65535 ps7=9999 ps8=65535
EVENTS : 398508
TIME : 4.964 mins
DEAD TIME: 7.17%
TRIGGER RATES: PRES/REAL
T3:1417.9/2835.8 Hz T4:23.4/327.2 Hz T5: 0.0/0.0 Hz T8: 0.0/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T3: 422345/844690 T4: 6961/97467 T5: 0/0 T8: 4/305012
AVERAGE CURRENT
BCM x1 : 50.0838uA BCM x3 : 50.1693uA BCM x10: 43.4707uA
APPROXIMATE BCM CHARGES (C)
BCM u1 : 0.01496 BCM u3 : 0.01496 BCM u10: 0.01284
BCM d1 : 0.01488 BCM d3 : 0.01493 BCM d10: 0.01305
****************************
End-of-run EPICS data for Run Number 3063 at Fri Nov 30 05:29:20 EST 2007
Wien angle : 12.3659
Half-wave plate (off=out) : IN
Left Arm D1 momentum : 0.124182
Left Arm arm angle : 120
Right Arm D1 momentum : 0.124084
Right Arm arm angle : 120
HALLA:p : 645.946
HALLA:dpp : 7.54716e-05
Tiefenbach Hall A energy : 645.946
Left Arm Top VDC Current : -2.68555
Left Arm Bottom VDC Current : 3.51562
Left Arm Q1 momentum : 0.124075
Left Arm Q1 power supply : 91.5923
Left Arm Q1 gauss meter : 0.008247
Left Arm Q2 gauss meter : -0.02803
Left Arm Q2 power supply current : 51.8239
Left Arm Q2 momentum : 0.123827
Left Arm Q2 power supply polarity : enabled
Left Arm D1 power supply current : 41.2661
Left Arm D1 momentum : 0.124182
Left Arm D1 NMR : 0.163551
Left Arm Q3 gauss meter : 0.02557
Left Arm Q3 power supply current : 47.5104
Left Arm Q3 momentum : 0.124162
Left Arm Q3 power supply polarity : enabled
Right Arm Q1 momentum : 0.122959
Right Arm Q1 power supply : 89.9901
Right Arm Q1 gauss meter : -0.00235
Right Arm Q2 power supply current : 52.3934
Right Arm Q2 momentum : 0.124017
Right Arm Q2 gauss meter : 0.02805
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 38.5644
Right Arm D1 momentum : 0.124111
Right Arm D1 NMR : 0.209189
Right Arm Q3 power supply current : 48.4773
Right Arm Q3 momentum : 0.124034
Right Arm Q3 gauss meter : 0.02186
Right Arm Q3 power supply polarity : disabled
Average current of the two cavities : 50.2159
Current on Unser monitor : 61.7265
Current on Upstream bcm : 50.292
Current on Downstream bcm : 50.1398
Upstream Cavity Coefficient : 43.377
Downstream Cavity Coefficient : 42.913
Current on IBC0L02 (source) : 49.5389
Hall C Current : 0
MBSY1c magnet current (amp) : 26.4309
MBSY1c Bdl : 161063
Hall A momentum (Tiefenbach) (HALLA:p) : 645.907
Hall A momentum orbit correction (dpp) : 1.41239e-05
Hall A setup momentum (MMSHLAE) : 645.369
Hall A energy (halla_MeV) : 645.907
Hall C energy (hallc_MeV) : 1877.05
Delta(E)/E width (MV_AI_DXWID) : 0.84204
IPM1C12.XPOS : -0.56357
IPM1H04A.XPOS : -1.08761
IPM1H04A.YPOS : -0.0402007
IPM1H04B.XPOS : -0.993076
IPM1H04B.YPOS : 0.00887513
Left Arm Collimator : 0.871387
HacL_HPE1313A:0_Ch58 : -0.320312
HacL_HPE1313A:0_Ch55 : 22.6074
HacL_HPE1313A:0_Ch54 : -0.28125
SLI data valid? : Yes
SLI horiz size mm : 0.291267
SLI Energy spread *10^5 : 5.39384
SLI x position : 1.17764
SLI vert. size mm : 0.0967291
SLI y position : 1.72019