Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 05:57:11 on November 30, 2007

    Entry number 217232

    keyword=End_of_Run_3064
    ****************************
     Run Number: 3064
     End of Run Comment:
    Run_type=Production,target_type=LH2 15cm + Pb foil Loop3,beam_e0=0.6458457,beam_raster=on,leftarm_p=0.12418,leftarm_theta=120,leftarm_colli=out,rightarm_p=0.15321,rightarm_theta=120,rightarm_colli=out,comment_text=
     
    
    PRESCALE FACTORS:ps1=16777212   ps2=16777215   ps3=4   ps4=35   ps5=65535   ps6=65535   ps7=9999   ps8=65535   
    
    EVENTS   : 1077131      
    TIME     : 17.888 mins  
    
    DEAD TIME:   1.25%      
    
    TRIGGER RATES:   PRES/REAL
    T3:995.9/3983.4 Hz   T4:20.4/715.1 Hz   T5: 0.0/0.0  Hz   T8: 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T3:1068849/4275398  T4:  21930/767561   T5:      0/0        T8:     16/1099060  
    
    AVERAGE CURRENT
    BCM x1 : 49.5034uA  BCM x3 : 49.5732uA  BCM x10: 43.2105uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 : 0.05327        BCM u3 : 0.05326        BCM u10: 0.04604        
    
    BCM d1 : 0.053          BCM d3 : 0.05315        BCM d10: 0.04671        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 3064 at Fri Nov 30 05:57:08 EST 2007
    
    Wien angle : 12.3659
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.12421
    Left Arm arm angle : 120
    Right Arm D1 momentum : 0.1143
    Right Arm arm angle : 120
    HALLA:p : 645.898
    HALLA:dpp : 0
    Tiefenbach Hall A energy : 645.898
    Left Arm Top VDC Current : 0.0976562
    Left Arm Bottom VDC Current : 4.19922
    Left Arm Q1 momentum : 0.124075
    Left Arm Q1 power supply : 91.5923
    Left Arm Q1 gauss meter : 0.008239
    Left Arm Q2 gauss meter : -0.02802
    Left Arm Q2 power supply current : 51.824
    Left Arm Q2 momentum : 0.123915
    Left Arm Q2 power supply polarity : enabled
    Left Arm D1 power supply current : 41.2664
    Left Arm D1 momentum : 0.124238
    Left Arm D1 NMR : 0.158424
    Left Arm Q3 gauss meter : 0.02559
    Left Arm Q3 power supply current : 47.544
    Left Arm Q3 momentum : 0.124212
    Left Arm Q3 power supply polarity : enabled
    Right Arm Q1 momentum : 0.113256
    Right Arm Q1 power supply : 81.4984
    Right Arm Q1 gauss meter : -0.002156
    Right Arm Q2 power supply current : 47.3214
    Right Arm Q2 momentum : 0.112393
    Right Arm Q2 gauss meter : 0.02541
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 20.2056
    Right Arm D1 momentum : 0.114191
    Right Arm D1 NMR : 0.24237
    Right Arm Q3 power supply current : 43.6495
    Right Arm Q3 momentum : 0.11228
    Right Arm Q3 gauss meter : 0.01976
    Right Arm Q3 power supply polarity : disabled
    Average current of the two cavities : 0.0234597
    Current on Unser monitor : 13.3024
    Current on Upstream bcm : 0.0347937
    Current on Downstream bcm : 0.0121258
    Upstream Cavity Coefficient : 43.377
    Downstream Cavity Coefficient : 42.913
    Current on IBC0L02 (source) : 72.6435
    Hall C Current : 76.2
    MBSY1c magnet current (amp) : 26.4309
    MBSY1c Bdl : 161063
    Hall A momentum (Tiefenbach) (HALLA:p) : 645.898
    Hall A momentum orbit correction (dpp) : 0
    Hall A setup momentum (MMSHLAE) : 645.369
    Hall A energy (halla_MeV) : 645.898
    Hall C energy (hallc_MeV) : 1876.34
    Delta(E)/E width (MV_AI_DXWID) : 0.817731
    IPM1C12.XPOS : 0
    IPM1H04A.XPOS : 0
    IPM1H04A.YPOS : 0
    IPM1H04B.XPOS : 0
    IPM1H04B.YPOS : 0
    Left Arm Collimator : 0.871387
    HacL_HPE1313A:0_Ch58 : -0.319824
    HacL_HPE1313A:0_Ch55 : 22.5586
    HacL_HPE1313A:0_Ch54 : -0.280762
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 1.13292
    SLI vert. size mm : 0
    SLI y position : 1.75023