Privacy and Security Notice
Main INDEX
Monthly INDEX
PREV
NEXT
User name a-onl
Log entry time 06:13:14 on November 30, 2007
Entry number 217234
keyword=End_of_Run_3065
****************************
Run Number: 3065
End of Run Comment:
Run_type=Production,target_type=Carbon 50 degs Right,beam_e0=0.6458457,beam_raster=on,leftarm_p=0.12418,leftarm_theta=120,leftarm_colli=out,rightarm_p=0.15321,rightarm_theta=120,rightarm_colli=out,comment_text=
PRESCALE FACTORS:ps1=16777212 ps2=16777215 ps3=1 ps4=2 ps5=65535 ps6=65535 ps7=9999 ps8=65535
EVENTS : 123402
TIME : 9.492 mins
DEAD TIME: 4.18%
TRIGGER RATES: PRES/REAL
T3:200.4/200.4 Hz T4:25.8/51.6 Hz T5: 0.0/0.0 Hz T8: 0.0/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T3: 114104/114104 T4: 14688/29377 T5: 0/0 T8: 8/583173
AVERAGE CURRENT
BCM x1 : 50.4475uA BCM x3 : 50.5206uA BCM x10: 43.6436uA
APPROXIMATE BCM CHARGES (C)
BCM u1 : 0.02879 BCM u3 : 0.02879 BCM u10: 0.02463
BCM d1 : 0.02867 BCM d3 : 0.02875 BCM d10: 0.02508
****************************
End-of-run EPICS data for Run Number 3065 at Fri Nov 30 06:13:11 EST 2007
Wien angle : 12.3659
Half-wave plate (off=out) : IN
Left Arm D1 momentum : 0.124154
Left Arm arm angle : 120
Right Arm D1 momentum : 0.114
Right Arm arm angle : 120
HALLA:p : 645.82
HALLA:dpp : -0.000119635
Tiefenbach Hall A energy : 645.82
Left Arm Top VDC Current : 4.39453
Left Arm Bottom VDC Current : -1.5625
Left Arm Q1 momentum : 0.124153
Left Arm Q1 power supply : 91.5923
Left Arm Q1 gauss meter : 0.008244
Left Arm Q2 gauss meter : -0.02801
Left Arm Q2 power supply current : 51.8239
Left Arm Q2 momentum : 0.123871
Left Arm Q2 power supply polarity : enabled
Left Arm D1 power supply current : 41.2663
Left Arm D1 momentum : 0.124154
Left Arm D1 NMR : 0.428179
Left Arm Q3 gauss meter : 0.02558
Left Arm Q3 power supply current : 47.5443
Left Arm Q3 momentum : 0.124162
Left Arm Q3 power supply polarity : enabled
Right Arm Q1 momentum : 0.112036
Right Arm Q1 power supply : 81.5518
Right Arm Q1 gauss meter : -0.002133
Right Arm Q2 power supply current : 47.3216
Right Arm Q2 momentum : 0.112304
Right Arm Q2 gauss meter : 0.02539
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 23.8751
Right Arm D1 momentum : 0.114
Right Arm D1 NMR : 0.330593
Right Arm Q3 power supply current : 43.6493
Right Arm Q3 momentum : 0.112364
Right Arm Q3 gauss meter : 0.019788
Right Arm Q3 power supply polarity : disabled
Average current of the two cavities : 50.1693
Current on Unser monitor : 61.563
Current on Upstream bcm : 50.2946
Current on Downstream bcm : 50.044
Upstream Cavity Coefficient : 43.377
Downstream Cavity Coefficient : 42.913
Current on IBC0L02 (source) : 128.114
Hall C Current : 78.33
MBSY1c magnet current (amp) : 26.4309
MBSY1c Bdl : 161063
Hall A momentum (Tiefenbach) (HALLA:p) : 645.822
Hall A momentum orbit correction (dpp) : -0.000116322
Hall A setup momentum (MMSHLAE) : 645.369
Hall A energy (halla_MeV) : 645.823
Hall C energy (hallc_MeV) : 1876.32
Delta(E)/E width (MV_AI_DXWID) : 0.785994
IPM1C12.XPOS : -0.0729289
IPM1H04A.XPOS : -1.08009
IPM1H04A.YPOS : -0.0986378
IPM1H04B.XPOS : -0.979799
IPM1H04B.YPOS : -0.00344133
Left Arm Collimator : 0.871338
HacL_HPE1313A:0_Ch58 : -0.320801
HacL_HPE1313A:0_Ch55 : 22.5098
HacL_HPE1313A:0_Ch54 : -0.281738
SLI data valid? : Yes
SLI horiz size mm : 0.304962
SLI Energy spread *10^5 : 5.64745
SLI x position : 1.13292
SLI vert. size mm : 0.104909
SLI y position : 1.72019