Privacy and Security Notice
Main INDEX
Monthly INDEX
PREV
NEXT
User name a-onl
Log entry time 07:05:14 on November 30, 2007
Entry number 217244
keyword=End_of_Run_3067
****************************
Run Number: 3067
End of Run Comment:
Run_type=Production,target_type=Iron 50 degs Right,beam_e0=0.6458457,beam_raster=on,leftarm_p=0.12418,leftarm_theta=120,leftarm_colli=out,rightarm_p=0.15321,rightarm_theta=120,rightarm_colli=out,comment_text=
PRESCALE FACTORS:ps1=16777212 ps2=16777215 ps3=1 ps4=9 ps5=65535 ps6=65535 ps7=9999 ps8=65535
EVENTS : 370465
TIME : 19.885 mins
DEAD TIME: 4.74%
TRIGGER RATES: PRES/REAL
T3:306.5/306.5 Hz T4:19.4/174.9 Hz T5: 0.0/0.0 Hz T8: 0.0/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T3: 365740/365740 T4: 23192/208729 T5: 0/0 T8: 18/1221750
AVERAGE CURRENT
BCM x1 : 49.8688uA BCM x3 : 49.9243uA BCM x10: 43.3927uA
APPROXIMATE BCM CHARGES (C)
BCM u1 : 0.05963 BCM u3 : 0.05962 BCM u10: 0.05134
BCM d1 : 0.05937 BCM d3 : 0.05951 BCM d10: 0.0522
****************************
End-of-run EPICS data for Run Number 3067 at Fri Nov 30 07:05:11 EST 2007
Wien angle : 12.3659
Half-wave plate (off=out) : IN
Left Arm D1 momentum : 0.112379
Left Arm arm angle : 120
Right Arm D1 momentum : 0.112065
Right Arm arm angle : 120
HALLA:p : 645.831
HALLA:dpp : -0.000102678
Tiefenbach Hall A energy : 645.831
Left Arm Top VDC Current : 3.36914
Left Arm Bottom VDC Current : 0.244141
Left Arm Q1 momentum : 0.112418
Left Arm Q1 power supply : 82.5666
Left Arm Q1 gauss meter : 0.00749
Left Arm Q2 gauss meter : -0.02535
Left Arm Q2 power supply current : 46.7651
Left Arm Q2 momentum : 0.112171
Left Arm Q2 power supply polarity : enabled
Left Arm D1 power supply current : 37.2588
Left Arm D1 momentum : 0.112379
Left Arm D1 NMR : 0.333014
Left Arm Q3 gauss meter : 0.02321
Left Arm Q3 power supply current : 42.8483
Left Arm Q3 momentum : 0.112304
Left Arm Q3 power supply polarity : enabled
Right Arm Q1 momentum : 0.113097
Right Arm Q1 power supply : 81.6587
Right Arm Q1 gauss meter : -0.002153
Right Arm Q2 power supply current : 47.3207
Right Arm Q2 momentum : 0.112304
Right Arm Q2 gauss meter : 0.02539
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 31.0813
Right Arm D1 momentum : 0.112038
Right Arm D1 NMR : 0.457322
Right Arm Q3 power supply current : 43.6492
Right Arm Q3 momentum : 0.112375
Right Arm Q3 gauss meter : 0.019767
Right Arm Q3 power supply polarity : disabled
Average current of the two cavities : 49.4189
Current on Unser monitor : 60.0284
Current on Upstream bcm : 49.6753
Current on Downstream bcm : 49.1626
Upstream Cavity Coefficient : 43.377
Downstream Cavity Coefficient : 42.913
Current on IBC0L02 (source) : 128.099
Hall C Current : 80.7
MBSY1c magnet current (amp) : 26.4309
MBSY1c Bdl : 161063
Hall A momentum (Tiefenbach) (HALLA:p) : 645.821
Hall A momentum orbit correction (dpp) : -0.000117973
Hall A setup momentum (MMSHLAE) : 645.369
Hall A energy (halla_MeV) : 645.822
Hall C energy (hallc_MeV) : 1876.34
Delta(E)/E width (MV_AI_DXWID) : 0.871192
IPM1C12.XPOS : -0.087134
IPM1H04A.XPOS : -1.04776
IPM1H04A.YPOS : -0.0666718
IPM1H04B.XPOS : -0.943498
IPM1H04B.YPOS : -0.000971437
Left Arm Collimator : 0.871387
HacL_HPE1313A:0_Ch58 : -0.320801
HacL_HPE1313A:0_Ch55 : 22.4121
HacL_HPE1313A:0_Ch54 : -0.282227
SLI data valid? : Yes
SLI horiz size mm : 0.308458
SLI Energy spread *10^5 : 5.71219
SLI x position : 1.28199
SLI vert. size mm : 0.0971481
SLI y position : 1.72019