Privacy and Security Notice
Main INDEX
Monthly INDEX
PREV
NEXT
User name a-onl
Log entry time 08:17:53 on November 30, 2007
Entry number 217258
keyword=End_of_Run_3070
****************************
Run Number: 3070
End of Run Comment:
Run_type=Production,target_type=Carbon 50 degs Right,beam_e0=0.6458457,beam_raster=on,leftarm_p=0.12418,leftarm_theta=120,leftarm_colli=out,rightarm_p=0.15321,rightarm_theta=120,rightarm_colli=out,comment_text=
PRESCALE FACTORS:ps1=16777212 ps2=16777215 ps3=1 p4=2 ps5=65535 ps6=65535 ps7=9999 ps8=65535
EVENTS : 261859
TIME : 25.201 mins
DEAD TIME: 23.95%
TRIGGER RATES: PRES/REAL
T3:178.1/178.1 Hz T4:49.6/49.6 Hz T5: 0.0/0.0 Hz T8: 0.0/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T3: 269371/269371 T4: 74943/74943 T5: 0/0 T8: 23/1548359
AVERAGE CURRENT
BCM x1 : 50.5061uA BCM x3 : 50.6151uA BCM x10: 43.2788uA
APPROXIMATE BCM CHARGES (C)
BCM u1 : 0.07635 BCM u3 : 0.07634 BCM u10: 0.06537
BCM d1 : 0.07638 BCM d3 : 0.07672 BCM d10: 0.06552
****************************
End-of-run EPICS data for Run Number 3070 at Fri Nov 30 08:17:50 EST 2007
Wien angle : 12.3659
Half-wave plate (off=out) : IN
Left Arm D1 momentum : 0.112351
Left Arm arm angle : 120
Right Arm D1 momentum : 0.112283
Right Arm arm angle : 120
HALLA:p : 645.821
HALLA:dpp : -0.000118505
Tiefenbach Hall A energy : 645.821
Left Arm Top VDC Current : 4.29688
Left Arm Bottom VDC Current : 3.36914
Left Arm Q1 momentum : 0.112372
Left Arm Q1 power supply : 82.62
Left Arm Q1 gauss meter : 0.007489
Left Arm Q2 gauss meter : -0.02533
Left Arm Q2 power supply current : 46.7663
Left Arm Q2 momentum : 0.112083
Left Arm Q2 power supply polarity : enabled
Left Arm D1 power supply current : 37.2505
Left Arm D1 momentum : 0.112324
Left Arm D1 NMR : 0.363965
Left Arm Q3 gauss meter : 0.02321
Left Arm Q3 power supply current : 42.8495
Left Arm Q3 momentum : 0.112304
Left Arm Q3 power supply polarity : enabled
Right Arm Q1 momentum : 0.112619
Right Arm Q1 power supply : 81.3916
Right Arm Q1 gauss meter : -0.002144
Right Arm Q2 power supply current : 47.3209
Right Arm Q2 momentum : 0.112349
Right Arm Q2 gauss meter : 0.0254
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 34.7184
Right Arm D1 momentum : 0.112256
Right Arm D1 NMR : 0.177747
Right Arm Q3 power supply current : 43.6501
Right Arm Q3 momentum : 0.112331
Right Arm Q3 gauss meter : 0.019769
Right Arm Q3 power supply polarity : disabled
Average current of the two cavities : 49.8599
Current on Unser monitor : 61.4888
Current on Upstream bcm : 49.9548
Current on Downstream bcm : 49.7651
Upstream Cavity Coefficient : 43.377
Downstream Cavity Coefficient : 42.913
Current on IBC0L02 (source) : 128.35
Hall C Current : 78.63
MBSY1c magnet current (amp) : 26.4309
MBSY1c Bdl : 161063
Hall A momentum (Tiefenbach) (HALLA:p) : 645.82
Hall A momentum orbit correction (dpp) : -0.000120204
Hall A setup momentum (MMSHLAE) : 645.369
Hall A energy (halla_MeV) : 645.82
Hall C energy (hallc_MeV) : 1876.33
Delta(E)/E width (MV_AI_DXWID) : 0.783563
IPM1C12.XPOS : -0.0671393
IPM1H04A.XPOS : -1.0674
IPM1H04A.YPOS : -0.0755797
IPM1H04B.XPOS : -0.985688
IPM1H04B.YPOS : 0.00170916
Left Arm Collimator : 0.871387
HacL_HPE1313A:0_Ch58 : -0.318359
HacL_HPE1313A:0_Ch55 : 22.9004
HacL_HPE1313A:0_Ch54 : -0.281738
SLI data valid? : Yes
SLI horiz size mm : 0.291828
SLI Energy spread *10^5 : 5.40422
SLI x position : 1.43106
SLI vert. size mm : 0.0985856
SLI y position : 1.7277