keyword=End_of_Run_3071
****************************
Run Number: 3071
End of Run Comment:
Run_type=Production,target_type=Carbon 50 degs Right,beam_e0=0.6458457,beam_raster=on,leftarm_p=0.12418,leftarm_theta=120,leftarm_colli=out,rightarm_p=0.15321,rightarm_theta=120,rightarm_colli=out,comment_text=check raster
PRESCALE FACTORS:ps1=16777212 ps2=16777215 ps3=1 p4=2 ps5=65535 ps6=65535 ps7=9999 ps8=65535
EVENTS : 13606
TIME : 10.961 mins
DEAD TIME: 30.08%
TRIGGER RATES: PRES/REAL
T3:20.9/20.9 Hz T4: 8.7/8.7 Hz T5: 0.0/0.0 Hz T8: 0.0/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T3: 13757/13757 T4: 5693/5693 T5: 0/0 T8: 10/673468
AVERAGE CURRENT
BCM x1 : 3.2514 uA BCM x3 : 3.2537 uA BCM x10: 3.2811 uA
APPROXIMATE BCM CHARGES (C)
BCM u1 : 0.002139 BCM u3 : 0.00214 BCM u10: 0.002156
BCM d1 : 0.002138 BCM d3 : 0.00214 BCM d10: 0.00216
****************************
End-of-run EPICS data for Run Number 3071 at Fri Nov 30 18:59:51 EST 2007
Wien angle : 12.3659
Half-wave plate (off=out) : IN
Left Arm D1 momentum : 0.622684
Left Arm arm angle : 60.0003
Right Arm D1 momentum : 0.622677
Right Arm arm angle : 59.9999
HALLA:p : 645.898
HALLA:dpp : 0
Tiefenbach Hall A energy : 645.898
Left Arm Top VDC Current : 2.92969
Left Arm Bottom VDC Current : 3.32031
Left Arm Q1 momentum : 0.622707
Left Arm Q1 power supply : 468.482
Left Arm Q1 gauss meter : -0.03945
Left Arm Q2 gauss meter : 0.14165
Left Arm Q2 power supply current : 271.595
Left Arm Q2 momentum : 0.630736
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 206.364
Left Arm D1 momentum : 0.622684
Left Arm D1 NMR : 0.230631
Left Arm Q3 gauss meter : -0.1257
Left Arm Q3 power supply current : 247.879
Left Arm Q3 momentum : 0.622625
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 momentum : 0.622752
Right Arm Q1 power supply : 468.215
Right Arm Q1 gauss meter : -0.011803
Right Arm Q2 power supply current : 267.978
Right Arm Q2 momentum : 0.622673
Right Arm Q2 gauss meter : 0.14067
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 213.856
Right Arm D1 momentum : 0.622677
Right Arm D1 NMR : 0.231068
Right Arm Q3 power supply current : 247.782
Right Arm Q3 momentum : 0.62271
Right Arm Q3 gauss meter : 0.1109
Right Arm Q3 power supply polarity : disabled
Average current of the two cavities : 0.0229715
Current on Unser monitor : 12.0965
Current on Upstream bcm : 0.0340875
Current on Downstream bcm : 0.0118555
Upstream Cavity Coefficient : 43.377
Downstream Cavity Coefficient : 42.913
Current on IBC0L02 (source) : 0.00267463
Hall C Current : 0
MBSY1c magnet current (amp) : 26.4309
MBSY1c Bdl : 161063
Hall A momentum (Tiefenbach) (HALLA:p) : 645.898
Hall A momentum orbit correction (dpp) : 0
Hall A setup momentum (MMSHLAE) : 645.369
Hall A energy (halla_MeV) : 645.898
Hall C energy (hallc_MeV) : 1873.39
Delta(E)/E width (MV_AI_DXWID) : 0
IPM1C12.XPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Left Arm Collimator : 0.871387
HacL_HPE1313A:0_Ch58 : -0.336914
HacL_HPE1313A:0_Ch55 : 22.7539
HacL_HPE1313A:0_Ch54 : -0.197266
SLI data valid? : No
SLI horiz size mm : 0
SLI Energy spread *10^5 : 0
SLI x position : 1.23727
SLI vert. size mm : 0
SLI y position : 1.7277