    keyword=End_of_Run_21301
    ****************************
     Run Number: 21301
     End of Run Comment:
    Run_type=Production,target_type=Carbon 50 degs Left,beam_e0=0.64602,beam_raster=on,beam_halfwaveplate=out,leftarm_p=0.62267,leftarm_theta=60,leftarm_colli=out,rightarm_p=0.62267,rightarm_theta=60,rightarm_colli=out,comment_text=
     
    
    PRESCALE FACTORS:ps1=1   ps2=2   ps3=16777215   ps4=16777215   ps5=65535   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS   : 20406        
    TIME     : 5.862 mins  
    
    DEAD TIME:   2.25%      
    
    TRIGGER RATES:   PRES/REAL
    T1:39.3/39.3 Hz   T2:20.1/40.1 Hz   T8: 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1:  13820/13820    T2:   7053/14106    T8:      5/360177   
    
    AVERAGE CURRENT
    BCM x1 : 47.3949uA  BCM x3 : 74.5561uA  BCM x10: 20.5332uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 : 0.01672        BCM u3 : 0.01672        BCM u10: -5.558E-06     
    
    BCM d1 : 0.01662        BCM d3 : 0.03573        BCM d10: 0.01445        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 21301 at Fri Nov 30 21:20:39 EST 2007
    
    Wien angle : 12.3659
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.622685
    Left Arm arm angle : 60.0003
    Right Arm D1 momentum : 0.622682
    Right Arm arm angle : 59.9999
    HALLA:p : 645.898
    HALLA:dpp : 0
    Tiefenbach Hall A energy : 645.898
    Left Arm Top VDC Current : 3.32031
    Left Arm Bottom VDC Current : 1.80664
    Left Arm Q1 momentum : 0.622707
    Left Arm Q1 power supply : 468.482
    Left Arm Q1 gauss meter : -0.03946
    Left Arm Q2 gauss meter : 0.14174
    Left Arm Q2 power supply current : 271.594
    Left Arm Q2 momentum : 0.630735
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 206.362
    Left Arm D1 momentum : 0.622685
    Left Arm D1 NMR : 0.230631
    Left Arm Q3 gauss meter : -0.12569
    Left Arm Q3 power supply current : 247.879
    Left Arm Q3 momentum : 0.622627
    Left Arm Q3 power supply polarity : disabled
    Right Arm Q1 momentum : 0.622681
    Right Arm Q1 power supply : 468.215
    Right Arm Q1 gauss meter : -0.011792
    Right Arm Q2 power supply current : 267.977
    Right Arm Q2 momentum : 0.622671
    Right Arm Q2 gauss meter : 0.14066
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 213.78
    Right Arm D1 momentum : 0.622684
    Right Arm D1 NMR : 0.231071
    Right Arm Q3 power supply current : 247.781
    Right Arm Q3 momentum : 0.622709
    Right Arm Q3 gauss meter : 0.1109
    Right Arm Q3 power supply polarity : disabled
    Average current of the two cavities : 0.782931
    Current on Unser monitor : 12.2522
    Current on Upstream bcm : 1.55385
    Current on Downstream bcm : 0.0120174
    Upstream Cavity Coefficient : 43.377
    Downstream Cavity Coefficient : 42.913
    Current on IBC0L02 (source) : 1.5519
    Hall C Current : 0
    MBSY1c magnet current (amp) : 26.4309
    MBSY1c Bdl : 161063
    Hall A momentum (Tiefenbach) (HALLA:p) : 645.829
    Hall A momentum orbit correction (dpp) : -0.000105893
    Hall A setup momentum (MMSHLAE) : 645.369
    Hall A energy (halla_MeV) : 645.829
    Hall C energy (hallc_MeV) : 1875.54
    Delta(E)/E width (MV_AI_DXWID) : 0
    IPM1C12.XPOS : -0.242483
    IPM1H04A.XPOS : -0.860309
    IPM1H04A.YPOS : 0.497695
    IPM1H04B.XPOS : -0.957566
    IPM1H04B.YPOS : 0.076067
    Left Arm Collimator : 0.871338
    HacL_HPE1313A:0_Ch58 : -0.334473
    HacL_HPE1313A:0_Ch55 : 22.998
    HacL_HPE1313A:0_Ch54 : -0.197266
    SLI data valid? : Yes
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 1.84099
    SLI vert. size mm : 0
    SLI y position : 1.74272