Privacy and Security Notice
Main INDEX
Monthly INDEX
PREV
NEXT
User name a-onl
Log entry time 21:34:43 on November 30, 2007
Entry number 217282
keyword=End_of_Run_3073
****************************
Run Number: 3073
End of Run Comment:
Run_type=Production,target_type=Carbon 50 degs Left,beam_e0=0.64602,beam_raster=on,leftarm_p=0.62267,leftarm_theta=60,leftarm_colli=out,rightarm_p=0.62267,rightarm_theta=60,rightarm_colli=out,comment_text=
PRESCALE FACTORS:ps1=16777212 ps2=16777215 ps3=1 p4=2 ps5=65535 ps6=65535 ps7=9999 ps8=65535
EVENTS : 30580
TIME : 5.294 mins
DEAD TIME: 36.90%
TRIGGER RATES: PRES/REAL
T3:98.9/98.9 Hz T4:53.7/53.7 Hz T5: 0.0/0.0 Hz T8: 0.0/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T3: 31399/31399 T4: 17061/17061 T5: 0/0 T8: 4/325263
AVERAGE CURRENT
BCM x1 : 49.8023uA BCM x3 : 49.8735uA BCM x10: 43.2328uA
APPROXIMATE BCM CHARGES (C)
BCM u1 : 0.01588 BCM u3 : 0.01588 BCM u10: 0.01367
BCM d1 : 0.01576 BCM d3 : 0.01581 BCM d10: 0.01379
****************************
End-of-run EPICS data for Run Number 3073 at Fri Nov 30 21:34:40 EST 2007
Wien angle : 12.3659
Half-wave plate (off=out) : IN
Left Arm D1 momentum : 0.622686
Left Arm arm angle : 60.0003
Right Arm D1 momentum : 0.622683
Right Arm arm angle : 59.9999
HALLA:p : 645.915
HALLA:dpp : 2.71582e-05
Tiefenbach Hall A energy : 645.915
Left Arm Top VDC Current : -1.80664
Left Arm Bottom VDC Current : -1.31836
Left Arm Q1 momentum : 0.622707
Left Arm Q1 power supply : 468.482
Left Arm Q1 gauss meter : -0.03946
Left Arm Q2 gauss meter : 0.14168
Left Arm Q2 power supply current : 271.595
Left Arm Q2 momentum : 0.630737
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 206.359
Left Arm D1 momentum : 0.622686
Left Arm D1 NMR : 0.230632
Left Arm Q3 gauss meter : -0.1257
Left Arm Q3 power supply current : 247.88
Left Arm Q3 momentum : 0.622629
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 momentum : 0.622752
Right Arm Q1 power supply : 468.215
Right Arm Q1 gauss meter : -0.011818
Right Arm Q2 power supply current : 267.979
Right Arm Q2 momentum : 0.622675
Right Arm Q2 gauss meter : 0.14069
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 213.781
Right Arm D1 momentum : 0.622681
Right Arm D1 NMR : 0.23107
Right Arm Q3 power supply current : 247.782
Right Arm Q3 momentum : 0.62271
Right Arm Q3 gauss meter : 0.11092
Right Arm Q3 power supply polarity : disabled
Average current of the two cavities : 49.8262
Current on Unser monitor : 60.3144
Current on Upstream bcm : 49.8955
Current on Downstream bcm : 49.757
Upstream Cavity Coefficient : 43.377
Downstream Cavity Coefficient : 42.913
Current on IBC0L02 (source) : 49.283
Hall C Current : 0
MBSY1c magnet current (amp) : 26.4309
MBSY1c Bdl : 161063
Hall A momentum (Tiefenbach) (HALLA:p) : 645.901
Hall A momentum orbit correction (dpp) : 5.92763e-06
Hall A setup momentum (MMSHLAE) : 645.369
Hall A energy (halla_MeV) : 645.902
Hall C energy (hallc_MeV) : 1876.4
Delta(E)/E width (MV_AI_DXWID) : 0.988755
IPM1C12.XPOS : 0.485285
IPM1H04A.XPOS : -0.95165
IPM1H04A.YPOS : 0.0383633
IPM1H04B.XPOS : -0.988649
IPM1H04B.YPOS : 0.0100855
Left Arm Collimator : 0.871338
HacL_HPE1313A:0_Ch58 : -0.335938
HacL_HPE1313A:0_Ch55 : 22.8516
HacL_HPE1313A:0_Ch54 : -0.197754
SLI data valid? : Yes
SLI horiz size mm : 0.219674
SLI Energy spread *10^5 : 4.06803
SLI x position : 1.84099
SLI vert. size mm : 0
SLI y position : 1.74272