Run Number: 3074
End of Run Comment:
Run_type=Production,target_type=Carbon 50 degs Left,beam_e0=0.64602,beam_raster=on,leftarm_p=0.62267,leftarm_theta=60,leftarm_colli=out,rightarm_p=0.62267,rightarm_theta=60,rightarm_colli=out,comment_text=
PRESCALE FACTORS:ps1=16777212 ps2=16777215 ps3=1 p4=2 ps5=65535 ps6=65535 ps7=9999 ps8=65535
EVENTS : 7289
TIME : 1.334 mins
DEAD TIME: 38.86%
TRIGGER RATES: PRES/REAL
T3:97.1/97.1 Hz T4:51.8/51.8 Hz T5: 0.0/0.0 Hz T8: 0.0/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T3: 7772/7772 T4: 4150/4150 T5: 0/0 T8: 1/81987
AVERAGE CURRENT
BCM x1 : 50.1710uA BCM x3 : 50.2250uA BCM x10: 43.3379uA
APPROXIMATE BCM CHARGES (C)
BCM u1 : 0.004035 BCM u3 : 0.004035 BCM u10: 0.003459
BCM d1 : 0.003998 BCM d3 : 0.004008 BCM d10: 0.003481
****************************
End-of-run EPICS data for Run Number 3074 at Fri Nov 30 22:10:33 EST 2007
Wien angle : 12.3659
Half-wave plate (off=out) : IN
Left Arm D1 momentum : 0.622685
Left Arm arm angle : 60.0003
Right Arm D1 momentum : 0.622682
Right Arm arm angle : 59.9999
HALLA:p : 646.252
HALLA:dpp : 0.000548575
Tiefenbach Hall A energy : 646.252
Left Arm Top VDC Current : -1.26953
Left Arm Bottom VDC Current : -1.41602
Left Arm Q1 momentum : 0.622707
Left Arm Q1 power supply : 468.482
Left Arm Q1 gauss meter : -0.03945
Left Arm Q2 gauss meter : 0.14174
Left Arm Q2 power supply current : 271.593
Left Arm Q2 momentum : 0.630731
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 206.361
Left Arm D1 momentum : 0.622686
Left Arm D1 NMR : 0.230632
Left Arm Q3 gauss meter : -0.1257
Left Arm Q3 power supply current : 247.88
Left Arm Q3 momentum : 0.622628
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 momentum : 0.622752
Right Arm Q1 power supply : 468.269
Right Arm Q1 gauss meter : -0.011805
Right Arm Q2 power supply current : 267.978
Right Arm Q2 momentum : 0.622671
Right Arm Q2 gauss meter : 0.14066
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 213.78
Right Arm D1 momentum : 0.622682
Right Arm D1 NMR : 0.23107
Right Arm Q3 power supply current : 247.781
Right Arm Q3 momentum : 0.622708
Right Arm Q3 gauss meter : 0.11092
Right Arm Q3 power supply polarity : disabled
Average current of the two cavities : 50.3253
Current on Unser monitor : 62.5903
Current on Upstream bcm : 50.425
Current on Downstream bcm : 50.2256
Upstream Cavity Coefficient : 43.377
Downstream Cavity Coefficient : 42.913
Current on IBC0L02 (source) : 49.6817
Hall C Current : 0
MBSY1c magnet current (amp) : 26.4309
MBSY1c Bdl : 161063
Hall A momentum (Tiefenbach) (HALLA:p) : 646.251
Hall A momentum orbit correction (dpp) : 0.000547542
Hall A setup momentum (MMSHLAE) : 645.369
Hall A energy (halla_MeV) : 646.251
Hall C energy (hallc_MeV) : 1876.4
Delta(E)/E width (MV_AI_DXWID) : 0.747248
IPM1C12.XPOS : -1.76813
IPM1H04A.XPOS : -0.379567
IPM1H04A.YPOS : 0.552776
IPM1H04B.XPOS : -0.655304
IPM1H04B.YPOS : 0.586888
Left Arm Collimator : 0.871338
HacL_HPE1313A:0_Ch58 : -0.335449
HacL_HPE1313A:0_Ch55 : 22.8516
HacL_HPE1313A:0_Ch54 : -0.196777
SLI data valid? : Yes
SLI horiz size mm : 0.0355341
SLI Energy spread *10^5 : 0.658038
SLI x position : 1.7441
SLI vert. size mm : 0.0756585
SLI y position : 1.74272