keyword=End_of_Run_3075
****************************
Run Number: 3075
End of Run Comment:
Run_type=Test,target_type=Carbon 50 degs Left,beam_e0=0.64602,beam_raster=on,leftarm_p=0.62267,leftarm_theta=60,leftarm_colli=out,rightarm_p=0.62267,rightarm_theta=60,rightarm_colli=out,comment_text=Raster check
PRESCALE FACTORS:ps1=16777212 ps2=16777215 ps3=1 p4=2 ps5=65535 ps6=65535 ps7=9999 ps8=65535
EVENTS : 33728
TIME : 5.752 mins
DEAD TIME: 36.47%
TRIGGER RATES: PRES/REAL
T3:100.1/100.1 Hz T4:53.7/53.7 Hz T5: 0.0/0.0 Hz T8: 0.0/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T3: 34544/34544 T4: 18548/18548 T5: 0/0 T8: 5/353419
AVERAGE CURRENT
BCM x1 : 49.6643uA BCM x3 : 49.7194uA BCM x10: 43.0892uA
APPROXIMATE BCM CHARGES (C)
BCM u1 : 0.01722 BCM u3 : 0.01722 BCM u10: 0.01484
BCM d1 : 0.01706 BCM d3 : 0.0171 BCM d10: 0.0149
****************************
End-of-run EPICS data for Run Number 3075 at Fri Nov 30 22:23:32 EST 2007
Wien angle : 12.3659
Half-wave plate (off=out) : IN
Left Arm D1 momentum : 0.622686
Left Arm arm angle : 60.0003
Right Arm D1 momentum : 0.622681
Right Arm arm angle : 59.9999
HALLA:p : 646.319
HALLA:dpp : 0.000652914
Tiefenbach Hall A energy : 646.319
Left Arm Top VDC Current : 2.97852
Left Arm Bottom VDC Current : 3.27148
Left Arm Q1 momentum : 0.622707
Left Arm Q1 power supply : 468.482
Left Arm Q1 gauss meter : -0.03947
Left Arm Q2 gauss meter : 0.14172
Left Arm Q2 power supply current : 271.593
Left Arm Q2 momentum : 0.630732
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 206.36
Left Arm D1 momentum : 0.622686
Left Arm D1 NMR : 0.230632
Left Arm Q3 gauss meter : -0.12569
Left Arm Q3 power supply current : 247.88
Left Arm Q3 momentum : 0.622628
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 momentum : 0.622681
Right Arm Q1 power supply : 468.269
Right Arm Q1 gauss meter : -0.011797
Right Arm Q2 power supply current : 267.977
Right Arm Q2 momentum : 0.62267
Right Arm Q2 gauss meter : 0.14067
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 213.781
Right Arm D1 momentum : 0.622681
Right Arm D1 NMR : 0.23107
Right Arm Q3 power supply current : 247.782
Right Arm Q3 momentum : 0.62271
Right Arm Q3 gauss meter : 0.11092
Right Arm Q3 power supply polarity : disabled
Average current of the two cavities : 49.9956
Current on Unser monitor : 61.2128
Current on Upstream bcm : 50.0753
Current on Downstream bcm : 49.9159
Upstream Cavity Coefficient : 43.377
Downstream Cavity Coefficient : 42.913
Current on IBC0L02 (source) : 49.4933
Hall C Current : 0
MBSY1c magnet current (amp) : 26.4309
MBSY1c Bdl : 161063
Hall A momentum (Tiefenbach) (HALLA:p) : 646.312
Hall A momentum orbit correction (dpp) : 0.000642269
Hall A setup momentum (MMSHLAE) : 645.369
Hall A energy (halla_MeV) : 646.313
Hall C energy (hallc_MeV) : 1876.4
Delta(E)/E width (MV_AI_DXWID) : 0.893581
IPM1C12.XPOS : -2.95268
IPM1H04A.XPOS : -1.05641
IPM1H04A.YPOS : -0.132213
IPM1H04B.XPOS : -1.00097
IPM1H04B.YPOS : 0.00520867
Left Arm Collimator : 0.871338
HacL_HPE1313A:0_Ch58 : -0.335449
HacL_HPE1313A:0_Ch55 : 22.8027
HacL_HPE1313A:0_Ch54 : -0.197754
SLI data valid? : Yes
SLI horiz size mm : 0.254097
SLI Energy spread *10^5 : 4.7055
SLI x position : 1.72919
SLI vert. size mm : 0.0998976
SLI y position : 1.74272