Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 22:26:51 on November 30, 2007

    Entry number 217289

    keyword=End_of_Run_3076
    ****************************
     Run Number: 3076
     End of Run Comment:
    Run_type=Test,target_type=Carbon 50 degs Left,beam_e0=0.64602,beam_raster=on,leftarm_p=0.62267,leftarm_theta=60,leftarm_colli=out,rightarm_p=0.62267,rightarm_theta=60,rightarm_colli=out,comment_text=Raster check
     
    
    PRESCALE FACTORS:ps1=16777212   ps2=16777215   ps3=1   p4=2   ps5=65535   ps6=65535   ps7=9999   ps8=65535   
    
    EVENTS   : 14214        
    TIME     : 2.489 mins  
    
    DEAD TIME:  38.02%      
    
    TRIGGER RATES:   PRES/REAL
    T3:98.9/98.9 Hz   T4:54.6/54.6 Hz   T5: 0.0/0.0  Hz   T8: 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T3:  14772/14772    T4:   8162/8162     T5:      0/0        T8:      2/152944   
    
    AVERAGE CURRENT
    BCM x1 : 49.9240uA  BCM x3 : 49.9830uA  BCM x10: 43.2114uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 : 0.007492       BCM u3 : 0.007491       BCM u10: 0.006439       
    
    BCM d1 : 0.007422       BCM d3 : 0.00744        BCM d10: 0.006469       
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 3076 at Fri Nov 30 22:26:47 EST 2007
    
    Wien angle : 12.3659
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.622686
    Left Arm arm angle : 60.0003
    Right Arm D1 momentum : 0.622681
    Right Arm arm angle : 59.9999
    HALLA:p : 646.296
    HALLA:dpp : 0.000617069
    Tiefenbach Hall A energy : 646.296
    Left Arm Top VDC Current : -2.39258
    Left Arm Bottom VDC Current : 2.7832
    Left Arm Q1 momentum : 0.622707
    Left Arm Q1 power supply : 468.482
    Left Arm Q1 gauss meter : -0.03945
    Left Arm Q2 gauss meter : 0.14171
    Left Arm Q2 power supply current : 271.593
    Left Arm Q2 momentum : 0.630733
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 206.363
    Left Arm D1 momentum : 0.622686
    Left Arm D1 NMR : 0.230632
    Left Arm Q3 gauss meter : -0.1257
    Left Arm Q3 power supply current : 247.881
    Left Arm Q3 momentum : 0.622631
    Left Arm Q3 power supply polarity : disabled
    Right Arm Q1 momentum : 0.622752
    Right Arm Q1 power supply : 468.269
    Right Arm Q1 gauss meter : -0.011796
    Right Arm Q2 power supply current : 267.978
    Right Arm Q2 momentum : 0.622672
    Right Arm Q2 gauss meter : 0.14067
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 213.78
    Right Arm D1 momentum : 0.622681
    Right Arm D1 NMR : 0.23107
    Right Arm Q3 power supply current : 247.782
    Right Arm Q3 momentum : 0.62271
    Right Arm Q3 gauss meter : 0.11092
    Right Arm Q3 power supply polarity : disabled
    Average current of the two cavities : 50.0046
    Current on Unser monitor : 62.1548
    Current on Upstream bcm : 50.0582
    Current on Downstream bcm : 49.9735
    Upstream Cavity Coefficient : 43.377
    Downstream Cavity Coefficient : 42.913
    Current on IBC0L02 (source) : 49.3681
    Hall C Current : 0
    MBSY1c magnet current (amp) : 26.4309
    MBSY1c Bdl : 161063
    Hall A momentum (Tiefenbach) (HALLA:p) : 646.294
    Hall A momentum orbit correction (dpp) : 0.000614279
    Hall A setup momentum (MMSHLAE) : 645.369
    Hall A energy (halla_MeV) : 646.294
    Hall C energy (hallc_MeV) : 1876.4
    Delta(E)/E width (MV_AI_DXWID) : 0.955026
    IPM1C12.XPOS : -2.89294
    IPM1H04A.XPOS : -1.04886
    IPM1H04A.YPOS : -0.137219
    IPM1H04B.XPOS : -0.99175
    IPM1H04B.YPOS : 0.0049817
    Left Arm Collimator : 0.871436
    HacL_HPE1313A:0_Ch58 : -0.334961
    HacL_HPE1313A:0_Ch55 : 22.8027
    HacL_HPE1313A:0_Ch54 : -0.196777
    SLI data valid? : Yes
    SLI horiz size mm : 0.249448
    SLI Energy spread *10^5 : 4.61941
    SLI x position : 1.71429
    SLI vert. size mm : 0.102025
    SLI y position : 1.73521