    User name a-onl

    Log entry time 22:33:00 on November 30, 2007

    Entry number 217294

    keyword=End_of_Run_3077
    ****************************
     Run Number: 3077
     End of Run Comment:
    Run_type=Production,target_type=Carbon 50 degs Left,beam_e0=0.64602,beam_raster=on,leftarm_p=0.62267,leftarm_theta=60,leftarm_colli=out,rightarm_p=0.62267,rightarm_theta=60,rightarm_colli=out,comment_text=
     
    
    PRESCALE FACTORS:ps1=16777212   ps2=16777215   ps3=1   p4=2   ps5=65535   ps6=65535   ps7=9999   ps8=65535   
    
    EVENTS   : 32855        
    TIME     : 5.642 mins  
    
    DEAD TIME:  37.01%      
    
    TRIGGER RATES:   PRES/REAL
    T3:99.5/99.5 Hz   T4:54.6/54.6 Hz   T5: 0.0/0.0  Hz   T8: 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T3:  33673/33673    T4:  18486/18486    T5:      0/0        T8:      5/346658   
    
    AVERAGE CURRENT
    BCM x1 : 49.4316uA  BCM x3 : 49.4973uA  BCM x10: 42.9826uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 : 0.01681        BCM u3 : 0.01681        BCM u10: 0.01453        
    
    BCM d1 : 0.01666        BCM d3 : 0.0167         BCM d10: 0.01457        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 3077 at Fri Nov 30 22:32:56 EST 2007
    
    Wien angle : 12.3659
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.622685
    Left Arm arm angle : 60.0003
    Right Arm D1 momentum : 0.622681
    Right Arm arm angle : 59.9999
    HALLA:p : 646.277
    HALLA:dpp : 0.000587483
    Tiefenbach Hall A energy : 646.277
    Left Arm Top VDC Current : 0.244141
    Left Arm Bottom VDC Current : 3.22266
    Left Arm Q1 momentum : 0.622707
    Left Arm Q1 power supply : 468.482
    Left Arm Q1 gauss meter : -0.03945
    Left Arm Q2 gauss meter : 0.14171
    Left Arm Q2 power supply current : 271.593
    Left Arm Q2 momentum : 0.630731
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 206.363
    Left Arm D1 momentum : 0.622685
    Left Arm D1 NMR : 0.230631
    Left Arm Q3 gauss meter : -0.12569
    Left Arm Q3 power supply current : 247.88
    Left Arm Q3 momentum : 0.622629
    Left Arm Q3 power supply polarity : disabled
    Right Arm Q1 momentum : 0.622752
    Right Arm Q1 power supply : 468.269
    Right Arm Q1 gauss meter : -0.011807
    Right Arm Q2 power supply current : 267.978
    Right Arm Q2 momentum : 0.622672
    Right Arm Q2 gauss meter : 0.14066
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 213.78
    Right Arm D1 momentum : 0.622681
    Right Arm D1 NMR : 0.23107
    Right Arm Q3 power supply current : 247.782
    Right Arm Q3 momentum : 0.622709
    Right Arm Q3 gauss meter : 0.11091
    Right Arm Q3 power supply polarity : disabled
    Average current of the two cavities : 50.0923
    Current on Unser monitor : 61.2879
    Current on Upstream bcm : 50.1372
    Current on Downstream bcm : 50.0475
    Upstream Cavity Coefficient : 43.377
    Downstream Cavity Coefficient : 42.913
    Current on IBC0L02 (source) : 49.5218
    Hall C Current : 0
    MBSY1c magnet current (amp) : 26.4309
    MBSY1c Bdl : 161063
    Hall A momentum (Tiefenbach) (HALLA:p) : 646.278
    Hall A momentum orbit correction (dpp) : 0.000589194
    Hall A setup momentum (MMSHLAE) : 645.369
    Hall A energy (halla_MeV) : 646.278
    Hall C energy (hallc_MeV) : 1876.4
    Delta(E)/E width (MV_AI_DXWID) : 0.937887
    IPM1C12.XPOS : -2.70735
    IPM1H04A.XPOS : -1.07218
    IPM1H04A.YPOS : -0.145794
    IPM1H04B.XPOS : -1.01188
    IPM1H04B.YPOS : -0.000337481
    Left Arm Collimator : 0.871387
    HacL_HPE1313A:0_Ch58 : -0.334473
    HacL_HPE1313A:0_Ch55 : 22.8516
    HacL_HPE1313A:0_Ch54 : -0.197754
    SLI data valid? : Yes
    SLI horiz size mm : 0.250604
    SLI Energy spread *10^5 : 4.64081
    SLI x position : 1.69938
    SLI vert. size mm : 0.102668
    SLI y position : 1.73521