Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name adev

    Log entry time 22:55:23 on November 30, 2007

    Entry number 217302

    keyword=End_of_Run_21305
    ****************************
     Run Number: 21305
     End of Run Comment:
    Run_type=Production,target_type=Dummy 10 cm,beam_e0=0.64602,beam_raster=on,beam_halfwaveplate=out,leftarm_p=0.62267,leftarm_theta=60,leftarm_colli=out,rightarm_p=0.62267,rightarm_theta=60,rightarm_colli=out,comment_text=
     
    
    PRESCALE FACTORS:ps1=1   ps2=35   ps3=16777215   ps4=16777215   ps5=65535   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS   : 103513       
    TIME     : 5.294 mins  
    
    DEAD TIME:   5.54%      
    
    TRIGGER RATES:   PRES/REAL
    T1:324.1/324.1 Hz   T2:20.9/732.4 Hz   T8: 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1: 102946/102946   T2:   6646/232626   T8:      4/325258   
    
    AVERAGE CURRENT
    BCM x1 : 50.7956uA  BCM x3 : 79.5032uA  BCM x10: 21.7841uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 : 0.01623        BCM u3 : 0.01622        BCM u10: 3E-06          
    
    BCM d1 : 0.01604        BCM d3 : 0.03429        BCM d10: 0.01384        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 21305 at Fri Nov 30 22:55:20 EST 2007
    
    Wien angle : 12.3659
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.622686
    Left Arm arm angle : 60.0003
    Right Arm D1 momentum : 0.622682
    Right Arm arm angle : 59.9999
    HALLA:p : 646.367
    HALLA:dpp : 0.000727257
    Tiefenbach Hall A energy : 646.367
    Left Arm Top VDC Current : -1.41602
    Left Arm Bottom VDC Current : -1.70898
    Left Arm Q1 momentum : 0.622707
    Left Arm Q1 power supply : 468.482
    Left Arm Q1 gauss meter : -0.03947
    Left Arm Q2 gauss meter : 0.14174
    Left Arm Q2 power supply current : 271.593
    Left Arm Q2 momentum : 0.630733
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 206.364
    Left Arm D1 momentum : 0.622686
    Left Arm D1 NMR : 0.230632
    Left Arm Q3 gauss meter : -0.12569
    Left Arm Q3 power supply current : 247.88
    Left Arm Q3 momentum : 0.622631
    Left Arm Q3 power supply polarity : disabled
    Right Arm Q1 momentum : 0.622752
    Right Arm Q1 power supply : 468.269
    Right Arm Q1 gauss meter : -0.011796
    Right Arm Q2 power supply current : 267.978
    Right Arm Q2 momentum : 0.622672
    Right Arm Q2 gauss meter : 0.14068
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 213.78
    Right Arm D1 momentum : 0.622683
    Right Arm D1 NMR : 0.23107
    Right Arm Q3 power supply current : 247.782
    Right Arm Q3 momentum : 0.622711
    Right Arm Q3 gauss meter : 0.11089
    Right Arm Q3 power supply polarity : disabled
    Average current of the two cavities : 51.1758
    Current on Unser monitor : 63.0401
    Current on Upstream bcm : 51.2188
    Current on Downstream bcm : 51.0913
    Upstream Cavity Coefficient : 43.377
    Downstream Cavity Coefficient : 42.913
    Current on IBC0L02 (source) : 50.2918
    Hall C Current : 0
    MBSY1c magnet current (amp) : 26.4309
    MBSY1c Bdl : 161063
    Hall A momentum (Tiefenbach) (HALLA:p) : 646.369
    Hall A momentum orbit correction (dpp) : 0.000730717
    Hall A setup momentum (MMSHLAE) : 645.369
    Hall A energy (halla_MeV) : 646.37
    Hall C energy (hallc_MeV) : 1876.4
    Delta(E)/E width (MV_AI_DXWID) : 0.776398
    IPM1C12.XPOS : -3.10971
    IPM1H04A.XPOS : -1.03723
    IPM1H04A.YPOS : -0.110598
    IPM1H04B.XPOS : -0.991881
    IPM1H04B.YPOS : 0.0192555
    Left Arm Collimator : 0.871436
    HacL_HPE1313A:0_Ch58 : -0.335449
    HacL_HPE1313A:0_Ch55 : 22.8027
    HacL_HPE1313A:0_Ch54 : -0.197754
    SLI data valid? : Yes
    SLI horiz size mm : 0.246599
    SLI Energy spread *10^5 : 4.56665
    SLI x position : 1.7441
    SLI vert. size mm : 0.104232
    SLI y position : 1.74272