Log entry time 23:08:05 on November 30, 2007
Entry number 217309
keyword=End_of_Run_3080
****************************
Run Number: 3080
End of Run Comment:
Run_type=Production,target_type=LH2 15cm + Pb foil Loop3,beam_e0=0.64602,beam_raster=on,leftarm_p=0.62267,leftarm_theta=60,leftarm_colli=out,rightarm_p=0.62267,rightarm_theta=60,rightarm_colli=out,comment_text=
PRESCALE FACTORS:ps1=16777212 ps2=16777215 ps3=1 p4=90 ps5=65535 ps6=65535 ps7=9999 ps8=65535
EVENTS : 373293
TIME : 5.441 mins
DEAD TIME: 64.47%
TRIGGER RATES: PRES/REAL
T3:1364.4/1364.4 Hz T4:1854.3/1854.3 Hz T5: 0.0/0.0 Hz T8: 0.0/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T3: 445428/445428 T4: 605357/605357 T5: 0/0 T8: 5/334298
AVERAGE CURRENT
BCM x1 : 49.6349uA BCM x3 : 49.6865uA BCM x10: 43.0422uA
APPROXIMATE BCM CHARGES (C)
BCM u1 : 0.01629 BCM u3 : 0.01628 BCM u10: 0.01404
BCM d1 : 0.01612 BCM d3 : 0.01616 BCM d10: 0.01407
****************************
End-of-run EPICS data for Run Number 3080 at Fri Nov 30 23:08:02 EST 2007
Wien angle : 12.3659
Half-wave plate (off=out) : IN
Left Arm D1 momentum : 0.622687
Left Arm arm angle : 60.0003
Right Arm D1 momentum : 0.622682
Right Arm arm angle : 59.9999
HALLA:p : 646.375
HALLA:dpp : 0.000739596
Tiefenbach Hall A energy : 646.375
Left Arm Top VDC Current : -1.31836
Left Arm Bottom VDC Current : -2.63672
Left Arm Q1 momentum : 0.622707
Left Arm Q1 power supply : 468.482
Left Arm Q1 gauss meter : -0.03947
Left Arm Q2 gauss meter : 0.14172
Left Arm Q2 power supply current : 271.593
Left Arm Q2 momentum : 0.630732
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 206.364
Left Arm D1 momentum : 0.622687
Left Arm D1 NMR : 0.230632
Left Arm Q3 gauss meter : -0.12569
Left Arm Q3 power supply current : 247.88
Left Arm Q3 momentum : 0.622629
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 momentum : 0.622752
Right Arm Q1 power supply : 468.269
Right Arm Q1 gauss meter : -0.011812
Right Arm Q2 power supply current : 267.978
Right Arm Q2 momentum : 0.622672
Right Arm Q2 gauss meter : 0.14069
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 213.78
Right Arm D1 momentum : 0.622681
Right Arm D1 NMR : 0.23107
Right Arm Q3 power supply current : 247.782
Right Arm Q3 momentum : 0.62271
Right Arm Q3 gauss meter : 0.1109
Right Arm Q3 power supply polarity : disabled
Average current of the two cavities : 49.4802
Current on Unser monitor : 60.9939
Current on Upstream bcm : 49.5239
Current on Downstream bcm : 49.4366
Upstream Cavity Coefficient : 43.377
Downstream Cavity Coefficient : 42.913
Current on IBC0L02 (source) : 108.105
Hall C Current : 60.27
MBSY1c magnet current (amp) : 26.4309
MBSY1c Bdl : 161063
Hall A momentum (Tiefenbach) (HALLA:p) : 646.374
Hall A momentum orbit correction (dpp) : 0.000737316
Hall A setup momentum (MMSHLAE) : 645.369
Hall A energy (halla_MeV) : 646.374
Hall C energy (hallc_MeV) : 1875.28
Delta(E)/E width (MV_AI_DXWID) : 0.830942
IPM1C12.XPOS : -3.33415
IPM1H04A.XPOS : -1.04294
IPM1H04A.YPOS : -0.166286
IPM1H04B.XPOS : -0.989667
IPM1H04B.YPOS : 0.00588721
Left Arm Collimator : 0.871338
HacL_HPE1313A:0_Ch58 : -0.334961
HacL_HPE1313A:0_Ch55 : 22.7539
HacL_HPE1313A:0_Ch54 : -0.198242
SLI data valid? : Yes
SLI horiz size mm : 0.248498
SLI Energy spread *10^5 : 4.60181
SLI x position : 1.77391
SLI vert. size mm : 0.0888334
SLI y position : 1.74272