Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name adev

    Log entry time 23:08:06 on November 30, 2007

    Entry number 217310

    keyword=End_of_Run_21306
    ****************************
     Run Number: 21306
     End of Run Comment:
    Run_type=Production,target_type=LH2 15cm + Pb foil Loop3,beam_e0=0.64602,beam_raster=on,beam_halfwaveplate=out,leftarm_p=0.62267,leftarm_theta=60,leftarm_colli=out,rightarm_p=0.62267,rightarm_theta=60,rightarm_colli=out,comment_text=
     
    
    PRESCALE FACTORS:ps1=1   ps2=100   ps3=16777215   ps4=16777215   ps5=65535   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS   : 232853       
    TIME     : 5.453 mins  
    
    DEAD TIME:  10.74%      
    
    TRIGGER RATES:   PRES/REAL
    T1:776.5/776.5 Hz   T2:20.9/2089.5 Hz   T8: 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1: 254042/254042   T2:   6836/683618   T8:      5/335013   
    
    AVERAGE CURRENT
    BCM x1 : 49.7123uA  BCM x3 : 77.9146uA  BCM x10: 21.5099uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 : 0.01635        BCM u3 : 0.01635        BCM u10: 1.368E-05      
    
    BCM d1 : 0.01617        BCM d3 : 0.03463        BCM d10: 0.01406        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 21306 at Fri Nov 30 23:08:03 EST 2007
    
    Wien angle : 12.3659
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.622687
    Left Arm arm angle : 60.0003
    Right Arm D1 momentum : 0.622681
    Right Arm arm angle : 59.9999
    HALLA:p : 646.374
    HALLA:dpp : 0.000737316
    Tiefenbach Hall A energy : 646.374
    Left Arm Top VDC Current : 1.26953
    Left Arm Bottom VDC Current : -0.78125
    Left Arm Q1 momentum : 0.622707
    Left Arm Q1 power supply : 468.482
    Left Arm Q1 gauss meter : -0.03946
    Left Arm Q2 gauss meter : 0.14168
    Left Arm Q2 power supply current : 271.593
    Left Arm Q2 momentum : 0.630732
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 206.364
    Left Arm D1 momentum : 0.622687
    Left Arm D1 NMR : 0.230632
    Left Arm Q3 gauss meter : -0.1257
    Left Arm Q3 power supply current : 247.88
    Left Arm Q3 momentum : 0.622629
    Left Arm Q3 power supply polarity : disabled
    Right Arm Q1 momentum : 0.622752
    Right Arm Q1 power supply : 468.269
    Right Arm Q1 gauss meter : -0.011804
    Right Arm Q2 power supply current : 267.978
    Right Arm Q2 momentum : 0.622672
    Right Arm Q2 gauss meter : 0.14068
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 213.779
    Right Arm D1 momentum : 0.622682
    Right Arm D1 NMR : 0.23107
    Right Arm Q3 power supply current : 247.782
    Right Arm Q3 momentum : 0.622711
    Right Arm Q3 gauss meter : 0.11092
    Right Arm Q3 power supply polarity : disabled
    Average current of the two cavities : 49.4802
    Current on Unser monitor : 60.3898
    Current on Upstream bcm : 49.5239
    Current on Downstream bcm : 49.4366
    Upstream Cavity Coefficient : 43.377
    Downstream Cavity Coefficient : 42.913
    Current on IBC0L02 (source) : 108.242
    Hall C Current : 59.61
    MBSY1c magnet current (amp) : 26.4309
    MBSY1c Bdl : 161063
    Hall A momentum (Tiefenbach) (HALLA:p) : 646.374
    Hall A momentum orbit correction (dpp) : 0.000737316
    Hall A setup momentum (MMSHLAE) : 645.369
    Hall A energy (halla_MeV) : 646.374
    Hall C energy (hallc_MeV) : 1875.28
    Delta(E)/E width (MV_AI_DXWID) : 0.83924
    IPM1C12.XPOS : -3.40127
    IPM1H04A.XPOS : -1.03919
    IPM1H04A.YPOS : -0.165831
    IPM1H04B.XPOS : -0.981729
    IPM1H04B.YPOS : 0.00328761
    Left Arm Collimator : 0.871387
    HacL_HPE1313A:0_Ch58 : -0.334473
    HacL_HPE1313A:0_Ch55 : 22.8027
    HacL_HPE1313A:0_Ch54 : -0.197754
    SLI data valid? : Yes
    SLI horiz size mm : 0.248498
    SLI Energy spread *10^5 : 4.60181
    SLI x position : 1.77391
    SLI vert. size mm : 0.0888334
    SLI y position : 1.74272