Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 23:22:39 on November 30, 2007

    Entry number 217313

    keyword=End_of_Run_3081
    ****************************
     Run Number: 3081
     End of Run Comment:
    Run_type=Production,target_type=4He 10cm Loop1 High Pressure,beam_e0=0.64602,beam_raster=on,leftarm_p=0.62267,leftarm_theta=60,leftarm_colli=out,rightarm_p=0.62267,rightarm_theta=60,rightarm_colli=out,comment_text=
     
    
    PRESCALE FACTORS:ps1=16777212   ps2=16777215   ps3=1   p4=30   ps5=65535   ps6=65535   ps7=9999   ps8=65535   
    
    EVENTS   : 248668       
    TIME     : 7.750 mins  
    
    DEAD TIME:  54.88%      
    
    TRIGGER RATES:   PRES/REAL
    T3:579.9/579.9 Hz   T4:605.3/605.3 Hz   T5: 0.0/0.0  Hz   T8: 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T3: 269643/269643   T4: 281495/281495   T5:      0/0        T8:      7/476177   
    
    AVERAGE CURRENT
    BCM x1 : 50.2714uA  BCM x3 : 50.3469uA  BCM x10: 43.3305uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 : 0.02349        BCM u3 : 0.02349        BCM u10: 0.02011        
    
    BCM d1 : 0.02326        BCM d3 : 0.02333        BCM d10: 0.02019        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 3081 at Fri Nov 30 23:22:36 EST 2007
    
    Wien angle : 12.3659
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.622686
    Left Arm arm angle : 60.0003
    Right Arm D1 momentum : 0.622682
    Right Arm arm angle : 59.9999
    HALLA:p : 646.386
    HALLA:dpp : 0.000756134
    Tiefenbach Hall A energy : 646.386
    Left Arm Top VDC Current : -2.92969
    Left Arm Bottom VDC Current : 2.88086
    Left Arm Q1 momentum : 0.622707
    Left Arm Q1 power supply : 468.482
    Left Arm Q1 gauss meter : -0.03945
    Left Arm Q2 gauss meter : 0.14166
    Left Arm Q2 power supply current : 271.593
    Left Arm Q2 momentum : 0.630731
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 206.363
    Left Arm D1 momentum : 0.622686
    Left Arm D1 NMR : 0.230632
    Left Arm Q3 gauss meter : -0.1257
    Left Arm Q3 power supply current : 247.881
    Left Arm Q3 momentum : 0.622628
    Left Arm Q3 power supply polarity : disabled
    Right Arm Q1 momentum : 0.622752
    Right Arm Q1 power supply : 468.269
    Right Arm Q1 gauss meter : -0.011795
    Right Arm Q2 power supply current : 267.978
    Right Arm Q2 momentum : 0.622673
    Right Arm Q2 gauss meter : 0.14067
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 213.78
    Right Arm D1 momentum : 0.622682
    Right Arm D1 NMR : 0.23107
    Right Arm Q3 power supply current : 247.782
    Right Arm Q3 momentum : 0.622709
    Right Arm Q3 gauss meter : 0.11089
    Right Arm Q3 power supply polarity : disabled
    Average current of the two cavities : 49.5746
    Current on Unser monitor : 61.3911
    Current on Upstream bcm : 49.4323
    Current on Downstream bcm : 49.717
    Upstream Cavity Coefficient : 43.377
    Downstream Cavity Coefficient : 42.913
    Current on IBC0L02 (source) : 129.195
    Hall C Current : 81.51
    MBSY1c magnet current (amp) : 26.4309
    MBSY1c Bdl : 161063
    Hall A momentum (Tiefenbach) (HALLA:p) : 646.384
    Hall A momentum orbit correction (dpp) : 0.000752899
    Hall A setup momentum (MMSHLAE) : 645.369
    Hall A energy (halla_MeV) : 646.384
    Hall C energy (hallc_MeV) : 1875.29
    Delta(E)/E width (MV_AI_DXWID) : 0
    IPM1C12.XPOS : -3.42172
    IPM1H04A.XPOS : -1.04521
    IPM1H04A.YPOS : -0.190277
    IPM1H04B.XPOS : -0.995517
    IPM1H04B.YPOS : -0.0117234
    Left Arm Collimator : 0.871338
    HacL_HPE1313A:0_Ch58 : -0.334473
    HacL_HPE1313A:0_Ch55 : 22.9004
    HacL_HPE1313A:0_Ch54 : -0.198242
    SLI data valid? : Yes
    SLI horiz size mm : 0.249548
    SLI Energy spread *10^5 : 4.62126
    SLI x position : 1.78882
    SLI vert. size mm : 0.0892223
    SLI y position : 1.75023