Privacy and Security Notice
Main INDEX
Monthly INDEX
PREV
NEXT
User name a-onl
Log entry time 23:48:46 on November 30, 2007
Entry number 217318
keyword=End_of_Run_3083
****************************
Run Number: 3083
End of Run Comment:
Run_type=Production,target_type=LH2 15cm + Pb foil Loop3,beam_e0=0.64602,beam_raster=on,leftarm_p=0.58056,leftarm_theta=60,leftarm_colli=out,rightarm_p=0.54129,rightarm_theta=60,rightarm_colli=out,comment_text=
PRESCALE FACTORS:ps1=16777212 ps2=16777215 ps3=1 p4=80 ps5=65535 ps6=65535 ps7=9999 ps8=65535
EVENTS : 490376
TIME : 6.852 mins
DEAD TIME: 62.58%
TRIGGER RATES: PRES/REAL
T3:1432.1/1432.1 Hz T4:1755.9/1755.9 Hz T5: 0.0/0.0 Hz T8: 0.0/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T3: 588822/588822 T4: 721926/721926 T5: 0/0 T8: 6/421017
AVERAGE CURRENT
BCM x1 : 50.4764uA BCM x3 : 50.5613uA BCM x10: 43.6098uA
APPROXIMATE BCM CHARGES (C)
BCM u1 : 0.02078 BCM u3 : 0.02078 BCM u10: 0.01778
BCM d1 : 0.02073 BCM d3 : 0.0208 BCM d10: 0.01808
****************************
End-of-run EPICS data for Run Number 3083 at Fri Nov 30 23:48:43 EST 2007
Wien angle : 12.3659
Half-wave plate (off=out) : IN
Left Arm D1 momentum : 0.580553
Left Arm arm angle : 60.0003
Right Arm D1 momentum : 0.54331
Right Arm arm angle : 59.9999
HALLA:p : 646.374
HALLA:dpp : 0.000737936
Tiefenbach Hall A energy : 646.374
Left Arm Top VDC Current : -2.73438
Left Arm Bottom VDC Current : 1.31836
Left Arm Q1 momentum : 0.58047
Left Arm Q1 power supply : 436.706
Left Arm Q1 gauss meter : -0.03679
Left Arm Q2 gauss meter : 0.13207
Left Arm Q2 power supply current : 253.192
Left Arm Q2 momentum : 0.587999
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 192.05
Left Arm D1 momentum : 0.580553
Left Arm D1 NMR : 0.215043
Left Arm Q3 gauss meter : -0.11727
Left Arm Q3 power supply current : 231.222
Left Arm Q3 momentum : 0.580787
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 momentum : 0.541286
Right Arm Q1 power supply : 407.012
Right Arm Q1 gauss meter : -0.010276
Right Arm Q2 power supply current : 233.054
Right Arm Q2 momentum : 0.541523
Right Arm Q2 gauss meter : 0.12245
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 186.096
Right Arm D1 momentum : 0.54331
Right Arm D1 NMR : 0.201592
Right Arm Q3 power supply current : 215.355
Right Arm Q3 momentum : 0.541216
Right Arm Q3 gauss meter : 0.09644
Right Arm Q3 power supply polarity : disabled
Average current of the two cavities : 50.86
Current on Unser monitor : 61.544
Current on Upstream bcm : 50.9034
Current on Downstream bcm : 50.8166
Upstream Cavity Coefficient : 43.377
Downstream Cavity Coefficient : 42.913
Current on IBC0L02 (source) : 130.016
Hall C Current : 79.71
MBSY1c magnet current (amp) : 26.4309
MBSY1c Bdl : 161063
Hall A momentum (Tiefenbach) (HALLA:p) : 646.375
Hall A momentum orbit correction (dpp) : 0.000738589
Hall A setup momentum (MMSHLAE) : 645.369
Hall A energy (halla_MeV) : 646.375
Hall C energy (hallc_MeV) : 1875.29
Delta(E)/E width (MV_AI_DXWID) : 0.757077
IPM1C12.XPOS : -3.32902
IPM1H04A.XPOS : -1.03162
IPM1H04A.YPOS : -0.211009
IPM1H04B.XPOS : -1.00349
IPM1H04B.YPOS : -0.0181686
Left Arm Collimator : 0.871387
HacL_HPE1313A:0_Ch58 : -0.333984
HacL_HPE1313A:0_Ch55 : 22.9004
HacL_HPE1313A:0_Ch54 : -0.197754
SLI data valid? : Yes
SLI horiz size mm : 0.244717
SLI Energy spread *10^5 : 4.5318
SLI x position : 1.77391
SLI vert. size mm : 0.0833763
SLI y position : 1.75023