Log entry time 17:05:08 on December 19, 2007
Entry number 222191
keyword=End_of_Run_4320
****************************
Run Number: 4320
End of Run Comment:
Run_type=Calibration,target_type=4He 10cm Loop1 High Pressure,beam_e0=2.839,beam_raster=on,leftarm_p=2.22892,leftarm_theta=15,leftarm_colli=out,rightarm_p=2.791,rightarm_theta=15,rightarm_colli=out,comment_text=He loop1
PRESCALE FACTORS:ps1=16777212 ps2=16777215 ps3=2 ps4=13 ps5=65535 ps6=65535 ps7=9999 ps8=65535
EVENTS : 611032
TIME : 5.621 mins
DEAD TIME: 10.28%
TRIGGER RATES: PRES/REAL
T3:1996.1/3992.1 Hz T4:23.5/305.0 Hz T5: 0.0/0.0 Hz T8: 0.0/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T3: 673193/1346386 T4: 7911/102855 T5: 0/0 T8: 5/345353
AVERAGE CURRENT
BCM x1 : 30.0656uA BCM x3 : 30.0710uA BCM x10: 29.9239uA
APPROXIMATE BCM CHARGES (C)
BCM u1 : 0.01017 BCM u3 : 0.01017 BCM u10: 0.01019
BCM d1 : 0.01011 BCM d3 : 0.01011 BCM d10: 0.009999
****************************
End-of-run EPICS data for Run Number 4320 at Wed Dec 19 17:05:05 EST 2007
Wien angle : 6.19568
Half-wave plate (off=out) : IN
Left Arm D1 momentum : 2.79106
Left Arm arm angle : 14.9991
Right Arm D1 momentum : 2.79102
Right Arm arm angle : 15.001
HALLA:p : 2845.74
HALLA:dpp : 3.03235e-05
Tiefenbach Hall A energy : 2845.74
Left Arm Top VDC Current : -2.83203
Left Arm Bottom VDC Current : 2.92969
Left Arm Q1 momentum : 2.79104
Left Arm Q1 power supply : 2099.79
Left Arm Q1 gauss meter : -0.17714
Left Arm Q2 gauss meter : 0.8379
Left Arm Q2 power supply current : 1596.63
Left Arm Q2 momentum : 3.70791
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 969.034
Left Arm D1 momentum : 2.79106
Left Arm D1 NMR : 1.03331
Left Arm Q3 gauss meter : -0.8076
Left Arm Q3 power supply current : 1597.74
Left Arm Q3 momentum : 4.01322
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 momentum : 2.79045
Right Arm Q1 power supply : 2098.24
Right Arm Q1 gauss meter : -0.05234
Right Arm Q2 power supply current : 1201.27
Right Arm Q2 momentum : 2.79127
Right Arm Q2 gauss meter : 0.6284
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 994.54
Right Arm D1 momentum : 2.79102
Right Arm D1 NMR : 1.03571
Right Arm Q3 power supply current : 1110.41
Right Arm Q3 momentum : 2.79062
Right Arm Q3 gauss meter : 0.4968
Right Arm Q3 power supply polarity : disabled
Average current of the two cavities : 30.2155
Current on Unser monitor : 42.9662
Current on Upstream bcm : 30.1807
Current on Downstream bcm : 30.2504
Upstream Cavity Coefficient : 43.377
Downstream Cavity Coefficient : 42.913
Current on IBC0L02 (source) : 69.7584
Hall C Current : 39.57
MBSY1c magnet current (amp) : 118.639
MBSY1c Bdl : 711246
Hall A momentum (Tiefenbach) (HALLA:p) : 2845.73
Hall A momentum orbit correction (dpp) : 2.81443e-05
Hall A setup momentum (MMSHLAE) : 2839.38
Hall A energy (halla_MeV) : 2845.73
Hall C energy (hallc_MeV) : 3549.64
Delta(E)/E width (MV_AI_DXWID) : 1.74754
IPM1C12.XPOS : -0.444549
IPM1H04A.XPOS : -1.98008
IPM1H04A.YPOS : 0.0255399
IPM1H04B.XPOS : -2.00048
IPM1H04B.YPOS : -0.00523198
Left Arm Collimator : 0.871387
HacL_HPE1313A:0_Ch58 : -0.188965
HacL_HPE1313A:0_Ch55 : 23.0957
HacL_HPE1313A:0_Ch54 : 0.00634766
SLI data valid? : Yes
SLI horiz size mm : 0.235107
SLI Energy spread *10^5 : 4.35384
SLI x position : 1.60994
SLI vert. size mm : 0.095365
SLI y position : 1.51737
-----
Target : L1 10cm
fan frequency loop 1 : 59.5
fan frequency loop 3 : 60
Encoder position : 3.30403e+07
Target type : 3.30403e+07
temperature loop 1(1) : 7
temperature loop 1(3) : 7.09
Heat exchange He : 7.5
temperature loop 3(1) : 18.85
temperature loop 3(3) : 19
Heat exchange H2 : 18.5
HPH He loop 1 : 35.6379
HPH He loop 2 : 92.8823
HPH H2 loop 3 : 195.896
-----