Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 17:17:51 on December 19, 2007

    Entry number 222199

    keyword=End_of_Run_4322
    ****************************
     Run Number: 4322
     End of Run Comment:
    Run_type=Calibration,target_type=4He 10cm Loop1 High Pressure,beam_e0=2.839,beam_raster=on,leftarm_p=2.22892,leftarm_theta=15,leftarm_colli=out,rightarm_p=2.791,rightarm_theta=15,rightarm_colli=out,comment_text=He loop1
     
    
    PRESCALE FACTORS:ps1=16777212   ps2=16777215   ps3=3   ps4=25   ps5=65535   ps6=65535   ps7=9999   ps8=65535   
    
    EVENTS   : 592605       
    TIME     : 4.757 mins  
    
    DEAD TIME:   7.17%      
    
    TRIGGER RATES:   PRES/REAL
    T3:2214.0/6641.9 Hz   T4:22.4/560.7 Hz   T5: 0.0/0.0  Hz   T8: 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T3: 631969/1895909  T4:   6401/160039   T5:      0/0        T8:      4/292299   
    
    AVERAGE CURRENT
    BCM x1 : 50.1484uA  BCM x3 : 50.1371uA  BCM x10: 43.4271uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 : 0.01436        BCM u3 : 0.01436        BCM u10: 0.01232        
    
    BCM d1 : 0.01427        BCM d3 : 0.01427        BCM d10: 0.01247        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 4322 at Wed Dec 19 17:17:48 EST 2007
    
    Wien angle : 6.19568
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 2.79106
    Left Arm arm angle : 14.9991
    Right Arm D1 momentum : 2.79102
    Right Arm arm angle : 15.001
    HALLA:p : 2845.67
    HALLA:dpp : 6.84089e-06
    Tiefenbach Hall A energy : 2845.67
    Left Arm Top VDC Current : 3.66211
    Left Arm Bottom VDC Current : 3.17383
    Left Arm Q1 momentum : 2.79104
    Left Arm Q1 power supply : 2099.79
    Left Arm Q1 gauss meter : -0.17714
    Left Arm Q2 gauss meter : 0.8379
    Left Arm Q2 power supply current : 1596.6
    Left Arm Q2 momentum : 3.70786
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 969.034
    Left Arm D1 momentum : 2.79106
    Left Arm D1 NMR : 1.03331
    Left Arm Q3 gauss meter : -0.8076
    Left Arm Q3 power supply current : 1597.72
    Left Arm Q3 momentum : 4.01318
    Left Arm Q3 power supply polarity : disabled
    Right Arm Q1 momentum : 2.79045
    Right Arm Q1 power supply : 2098.24
    Right Arm Q1 gauss meter : -0.05236
    Right Arm Q2 power supply current : 1201.27
    Right Arm Q2 momentum : 2.79126
    Right Arm Q2 gauss meter : 0.6284
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 994.541
    Right Arm D1 momentum : 2.79102
    Right Arm D1 NMR : 1.03571
    Right Arm Q3 power supply current : 1110.41
    Right Arm Q3 momentum : 2.79061
    Right Arm Q3 gauss meter : 0.4968
    Right Arm Q3 power supply polarity : disabled
    Average current of the two cavities : 50.1562
    Current on Unser monitor : 62.6507
    Current on Upstream bcm : 50.2206
    Current on Downstream bcm : 50.0918
    Upstream Cavity Coefficient : 43.377
    Downstream Cavity Coefficient : 42.913
    Current on IBC0L02 (source) : 89.6286
    Hall C Current : 40.32
    MBSY1c magnet current (amp) : 118.639
    MBSY1c Bdl : 711246
    Hall A momentum (Tiefenbach) (HALLA:p) : 2845.68
    Hall A momentum orbit correction (dpp) : 1.03976e-05
    Hall A setup momentum (MMSHLAE) : 2839.38
    Hall A energy (halla_MeV) : 2845.68
    Hall C energy (hallc_MeV) : 3549.65
    Delta(E)/E width (MV_AI_DXWID) : 1.71207
    IPM1C12.XPOS : -0.332789
    IPM1H04A.XPOS : -1.9588
    IPM1H04A.YPOS : 0.0287128
    IPM1H04B.XPOS : -2.00152
    IPM1H04B.YPOS : -0.000255585
    Left Arm Collimator : 0.871436
    HacL_HPE1313A:0_Ch58 : -0.188965
    HacL_HPE1313A:0_Ch55 : 23.1934
    HacL_HPE1313A:0_Ch54 : 0.00585938
    SLI data valid? : Yes
    SLI horiz size mm : 0.250922
    SLI Energy spread *10^5 : 4.64671
    SLI x position : 1.59503
    SLI vert. size mm : 0.0883111
    SLI y position : 1.51737
    -----
    Target : L1 10cm
    fan frequency loop 1 : 59.5
    fan frequency loop 3 : 60
    Encoder position : 3.30403e+07
    Target type : 3.30403e+07
    temperature loop 1(1) : 7.26
    temperature loop 1(3) : 7.39
    Heat exchange He : 7.8
    temperature loop 3(1) : 18.85
    temperature loop 3(3) : 19.01
    Heat exchange H2 : 18.5
    HPH He loop 1 : 0.0424476
    HPH He loop 2 : 98.6476
    HPH H2 loop 3 : 198.765
    -----