    keyword=End_of_Run_22180
    ****************************
     Run Number: 22180
     End of Run Comment:
    Run_type=Calibration,target_type=4He 10cm Loop1 High Pressure,beam_e0=2.839,beam_raster=on,beam_halfwaveplate=out,leftarm_p=2.22892,leftarm_theta=15,leftarm_colli=out,rightarm_p=2.791,rightarm_theta=15,rightarm_colli=out,comment_text=He loop1
     
    
    PRESCALE FACTORS:ps1=10   ps2=200   ps3=16777215   ps4=16777215   ps5=65535   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS   : 1130532      
    TIME     : 5.310 mins  
    
    DEAD TIME:   9.58%      
    
    TRIGGER RATES:   PRES/REAL
    T1:3906.0/39060.4 Hz   T2:18.0/3601.6 Hz   T8: 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1:1244548/12445482  T2:   5737/1147533  T8:      4/326268   
    
    AVERAGE CURRENT
    BCM x1 : 52.2700uA  BCM x3 : 52.2439uA  BCM x10: 20.9345uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 : 0.01672        BCM u3 : 0.01671        BCM u10: 0.0005538      
    
    BCM d1 : 0.01659        BCM d3 : 0.01658        BCM d10: 0.01279        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 22180 at Wed Dec 19 17:38:10 EST 2007
    
    Wien angle : 6.19568
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 2.79106
    Left Arm arm angle : 14.9991
    Right Arm D1 momentum : 2.79101
    Right Arm arm angle : 15.001
    HALLA:p : 2845.2
    HALLA:dpp : -0.000159895
    Tiefenbach Hall A energy : 2845.2
    Left Arm Top VDC Current : -1.9043
    Left Arm Bottom VDC Current : -4.3457
    Left Arm Q1 momentum : 2.79097
    Left Arm Q1 power supply : 2099.79
    Left Arm Q1 gauss meter : -0.17712
    Left Arm Q2 gauss meter : 0.6317
    Left Arm Q2 power supply current : 1201.91
    Left Arm Q2 momentum : 2.79125
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 969.036
    Left Arm D1 momentum : 2.79106
    Left Arm D1 NMR : 1.03331
    Left Arm Q3 gauss meter : -0.5625
    Left Arm Q3 power supply current : 1111.15
    Left Arm Q3 momentum : 2.79101
    Left Arm Q3 power supply polarity : disabled
    Right Arm Q1 momentum : 2.79045
    Right Arm Q1 power supply : 2098.24
    Right Arm Q1 gauss meter : -0.05234
    Right Arm Q2 power supply current : 1201.27
    Right Arm Q2 momentum : 2.79126
    Right Arm Q2 gauss meter : 0.6285
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 994.541
    Right Arm D1 momentum : 2.79101
    Right Arm D1 NMR : 1.03571
    Right Arm Q3 power supply current : 1110.41
    Right Arm Q3 momentum : 2.79061
    Right Arm Q3 gauss meter : 0.4968
    Right Arm Q3 power supply polarity : disabled
    Average current of the two cavities : 50.3868
    Current on Unser monitor : 61.7356
    Current on Upstream bcm : 50.4739
    Current on Downstream bcm : 50.2998
    Upstream Cavity Coefficient : 43.377
    Downstream Cavity Coefficient : 42.913
    Current on IBC0L02 (source) : 89.0526
    Hall C Current : 39.12
    MBSY1c magnet current (amp) : 118.639
    MBSY1c Bdl : 711246
    Hall A momentum (Tiefenbach) (HALLA:p) : 2845.23
    Hall A momentum orbit correction (dpp) : -0.000147786
    Hall A setup momentum (MMSHLAE) : 2839.38
    Hall A energy (halla_MeV) : 2845.23
    Hall C energy (hallc_MeV) : 3549.56
    Delta(E)/E width (MV_AI_DXWID) : 1.6801
    IPM1C12.XPOS : 0.0680856
    IPM1H04A.XPOS : -1.96761
    IPM1H04A.YPOS : 0.0482947
    IPM1H04B.XPOS : -1.99629
    IPM1H04B.YPOS : 0.00660545
    Left Arm Collimator : 0.871436
    HacL_HPE1313A:0_Ch58 : -0.189941
    HacL_HPE1313A:0_Ch55 : 23.1445
    HacL_HPE1313A:0_Ch54 : 0.00634766
    -----
    SLI data valid? : Yes
    SLI horiz size mm : 0.237928
    SLI Energy spread *10^5 : 4.40607
    SLI x position : 1.56522
    SLI vert. size mm : 0.091568
    SLI y position : 1.51737
    -----
    Target : L1 10cm
    Vacuum Pressure : 3.59087e-07
    fan frequency loop 1 : 59.5
    fan frequency loop 3 : 60
    Encoder position : 3.30403e+07
    Target type : 3.30403e+07
    temperature loop 1(1) : 6.98
    temperature loop 1(3) : 7.12
    Heat exchange He : 7.5
    temperature loop 3(1) : 18.85
    temperature loop 3(3) : 19
    Heat exchange H2 : 18.5
    HPH He loop 1 : 112.114