Privacy and Security Notice
Main INDEX
Monthly INDEX
PREV
NEXT
User name a-onl
Log entry time 17:38:15 on December 19, 2007
Entry number 222208
keyword=End_of_Run_4324
****************************
Run Number: 4324
End of Run Comment:
Run_type=Test,target_type=4He 10cm Loop1 High Pressure,beam_e0=2.839,beam_raster=on,leftarm_p=2.22892,leftarm_theta=15,leftarm_colli=out,rightarm_p=2.791,rightarm_theta=15,rightarm_colli=out,comment_text=He loop1
PRESCALE FACTORS:ps1=16777212 ps2=16777215 ps3=10 ps4=70 ps5=65535 ps6=65535 ps7=9999 ps8=65535
EVENTS : 1127425
TIME : 5.311 mins
DEAD TIME: 9.07%
TRIGGER RATES: PRES/REAL
T3:3869.1/38690.9 Hz T4:21.5/1502.8 Hz T5: 0.0/0.0 Hz T8: 0.0/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T3:1233006/12330065 T4: 6841/478917 T5: 0/0 T8: 4/326330
AVERAGE CURRENT
BCM x1 : 52.0936uA BCM x3 : 52.0704uA BCM x10: 40.4343uA
APPROXIMATE BCM CHARGES (C)
BCM u1 : 0.01666 BCM u3 : 0.01666 BCM u10: 0.01296
BCM d1 : 0.01654 BCM d3 : 0.01653 BCM d10: 0.01281
****************************
End-of-run EPICS data for Run Number 4324 at Wed Dec 19 17:38:11 EST 2007
Wien angle : 6.19568
Half-wave plate (off=out) : IN
Left Arm D1 momentum : 2.79106
Left Arm arm angle : 14.9991
Right Arm D1 momentum : 2.79101
Right Arm arm angle : 15.001
HALLA:p : 2845.2
HALLA:dpp : -0.000161161
Tiefenbach Hall A energy : 2845.23
Left Arm Top VDC Current : -8.05664
Left Arm Bottom VDC Current : -2.83203
Left Arm Q1 momentum : 2.79104
Left Arm Q1 power supply : 2099.79
Left Arm Q1 gauss meter : -0.17712
Left Arm Q2 gauss meter : 0.6318
Left Arm Q2 power supply current : 1201.91
Left Arm Q2 momentum : 2.79125
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 969.036
Left Arm D1 momentum : 2.79106
Left Arm D1 NMR : 1.03331
Left Arm Q3 gauss meter : -0.5625
Left Arm Q3 power supply current : 1111.15
Left Arm Q3 momentum : 2.79101
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 momentum : 2.79045
Right Arm Q1 power supply : 2098.24
Right Arm Q1 gauss meter : -0.05234
Right Arm Q2 power supply current : 1201.27
Right Arm Q2 momentum : 2.79126
Right Arm Q2 gauss meter : 0.6285
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 994.541
Right Arm D1 momentum : 2.79101
Right Arm D1 NMR : 1.03571
Right Arm Q3 power supply current : 1110.41
Right Arm Q3 momentum : 2.79061
Right Arm Q3 gauss meter : 0.4968
Right Arm Q3 power supply polarity : disabled
Average current of the two cavities : 53.1397
Current on Unser monitor : 61.7356
Current on Upstream bcm : 55.9796
Current on Downstream bcm : 50.2998
Upstream Cavity Coefficient : 43.377
Downstream Cavity Coefficient : 42.913
Current on IBC0L02 (source) : 94.4054
Hall C Current : 38.55
MBSY1c magnet current (amp) : 118.639
MBSY1c Bdl : 711246
Hall A momentum (Tiefenbach) (HALLA:p) : 2845.2
Hall A momentum orbit correction (dpp) : -0.000157957
Hall A setup momentum (MMSHLAE) : 2839.38
Hall A energy (halla_MeV) : 2845.2
Hall C energy (hallc_MeV) : 3549.62
Delta(E)/E width (MV_AI_DXWID) : 1.71581
IPM1C12.XPOS : 0.0764423
IPM1H04A.XPOS : -1.96991
IPM1H04A.YPOS : 0.038006
IPM1H04B.XPOS : -1.99815
IPM1H04B.YPOS : -0.000601649
Left Arm Collimator : 0.871387
HacL_HPE1313A:0_Ch58 : -0.188965
HacL_HPE1313A:0_Ch55 : 23.1445
HacL_HPE1313A:0_Ch54 : 0.00585938
SLI data valid? : Yes
SLI horiz size mm : 0.237928
SLI Energy spread *10^5 : 4.40607
SLI x position : 1.56522
SLI vert. size mm : 0.0937392
SLI y position : 1.51737
-----
Target : L1 10cm
fan frequency loop 1 : 60
fan frequency loop 3 : 60
Encoder position : 3.30403e+07
Target type : 3.30403e+07
temperature loop 1(1) : 7
temperature loop 1(3) : 7.13
Heat exchange He : 7.5
temperature loop 3(1) : 18.85
temperature loop 3(3) : 19
Heat exchange H2 : 18.5
HPH He loop 1 : 112.114
HPH He loop 2 : 2.67065
HPH H2 loop 3 : 184.626
-----