keyword=End_of_Run_4325
****************************
Run Number: 4325
End of Run Comment:
Run_type=Test,target_type=4He 10cm Loop1 High Pressure,beam_e0=2.839,beam_raster=on,leftarm_p=2.22892,leftarm_theta=15,leftarm_colli=out,rightarm_p=2.791,rightarm_theta=15,rightarm_colli=out,comment_text=He loop1
PRESCALE FACTORS:ps1=16777212 ps2=16777215 ps3=12 ps4=80 ps5=65535 ps6=65535 ps7=9999 ps8=65535
EVENTS : 1104507
TIME : 5.299 mins
DEAD TIME: 6.50%
TRIGGER RATES: PRES/REAL
T3:3692.7/44312.2 Hz T4:22.4/1791.4 Hz T5: 0.0/0.0 Hz T8: 0.0/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T3:1174150/14089808 T4: 7119/569597 T5: 0/0 T8: 4/325598
AVERAGE CURRENT
BCM x1 : 59.8839uA BCM x3 : 59.8332uA BCM x10: 41.5637uA
APPROXIMATE BCM CHARGES (C)
BCM u1 : 0.01911 BCM u3 : 0.0191 BCM u10: 0.0136
BCM d1 : 0.01897 BCM d3 : 0.01895 BCM d10: 0.01283
****************************
End-of-run EPICS data for Run Number 4325 at Wed Dec 19 17:45:25 EST 2007
Wien angle : 6.19568
Half-wave plate (off=out) : IN
Left Arm D1 momentum : 2.79106
Left Arm arm angle : 14.9991
Right Arm D1 momentum : 2.791
Right Arm arm angle : 15.001
HALLA:p : 2845.24
HALLA:dpp : -0.000143972
Tiefenbach Hall A energy : 2845.24
Left Arm Top VDC Current : -3.80859
Left Arm Bottom VDC Current : -7.27539
Left Arm Q1 momentum : 2.79097
Left Arm Q1 power supply : 2099.73
Left Arm Q1 gauss meter : -0.17713
Left Arm Q2 gauss meter : 0.6317
Left Arm Q2 power supply current : 1201.92
Left Arm Q2 momentum : 2.79126
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 969.035
Left Arm D1 momentum : 2.79106
Left Arm D1 NMR : 1.03331
Left Arm Q3 gauss meter : -0.5625
Left Arm Q3 power supply current : 1111.16
Left Arm Q3 momentum : 2.79102
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 momentum : 2.79045
Right Arm Q1 power supply : 2098.29
Right Arm Q1 gauss meter : -0.05235
Right Arm Q2 power supply current : 1201.27
Right Arm Q2 momentum : 2.79126
Right Arm Q2 gauss meter : 0.6285
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 994.541
Right Arm D1 momentum : 2.791
Right Arm D1 NMR : 1.03571
Right Arm Q3 power supply current : 1110.41
Right Arm Q3 momentum : 2.79061
Right Arm Q3 gauss meter : 0.4968
Right Arm Q3 power supply polarity : disabled
Average current of the two cavities : 68.3971
Current on Unser monitor : 78.1178
Current on Upstream bcm : 68.7292
Current on Downstream bcm : 68.0649
Upstream Cavity Coefficient : 43.377
Downstream Cavity Coefficient : 42.913
Current on IBC0L02 (source) : 107.894
Hall C Current : 39.99
MBSY1c magnet current (amp) : 118.639
MBSY1c Bdl : 711246
Hall A momentum (Tiefenbach) (HALLA:p) : 2845.25
Hall A momentum orbit correction (dpp) : -0.000141603
Hall A setup momentum (MMSHLAE) : 2839.38
Hall A energy (halla_MeV) : 2845.25
Hall C energy (hallc_MeV) : 3549.7
Delta(E)/E width (MV_AI_DXWID) : 1.68361
IPM1C12.XPOS : 0.0114386
IPM1H04A.XPOS : -1.96826
IPM1H04A.YPOS : 0.0253604
IPM1H04B.XPOS : -2.00167
IPM1H04B.YPOS : -0.0188742
Left Arm Collimator : 0.871436
HacL_HPE1313A:0_Ch58 : -0.189941
HacL_HPE1313A:0_Ch55 : 23.0469
HacL_HPE1313A:0_Ch54 : 0.00585938
SLI data valid? : Yes
SLI horiz size mm : 0.263389
SLI Energy spread *10^5 : 4.87758
SLI x position : 1.58012
SLI vert. size mm : 0.0969917
SLI y position : 1.51737
-----
Target : L1 10cm
fan frequency loop 1 : 60
fan frequency loop 3 : 60
Encoder position : 3.30403e+07
Target type : 3.30403e+07
temperature loop 1(1) : 6.99
temperature loop 1(3) : 7.15
Heat exchange He : 7.5
temperature loop 3(1) : 18.85
temperature loop 3(3) : 19
Heat exchange H2 : 18.5
HPH He loop 1 : 75.9432
HPH He loop 2 : 3.00125
HPH H2 loop 3 : 197.328
-----