NEXT
User name adev
Log entry time 18:37:51 on December 19, 2007
Entry number 222238
keyword=End_of_Run_22187
****************************
Run Number: 22187
End of Run Comment:
Run_type=Test,target_type=Carbon 50 degs Left,beam_e0=2.839,beam_raster=on,beam_halfwaveplate=out,leftarm_p=2.22892,leftarm_theta=15,leftarm_colli=out,rightarm_p=2.791,rightarm_theta=15,rightarm_colli=out,comment_text=C-left
PRESCALE FACTORS:ps1=2 ps2=12 ps3=16777215 ps4=16777215 ps5=65535 ps6=65535 ps7=65535 ps8=65535
EVENTS : 846108
TIME : 6.044 mins
DEAD TIME: 15.28%
TRIGGER RATES: PRES/REAL
T1:2733.1/5466.2 Hz T2:21.0/252.1 Hz T8: 0.0/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1: 991081/1982163 T2: 7616/91401 T8: 5/371326
AVERAGE CURRENT
BCM x1 : 50.5046uA BCM x3 : 50.4900uA BCM x10: 22.0114uA
APPROXIMATE BCM CHARGES (C)
BCM u1 : 0.01837 BCM u3 : 0.01836 BCM u10: 8.208E-05
BCM d1 : 0.01826 BCM d3 : 0.01826 BCM d10: 0.01588
****************************
End-of-run EPICS data for Run Number 22187 at Wed Dec 19 18:37:48 EST 2007
Wien angle : 6.19568
Half-wave plate (off=out) : IN
Left Arm D1 momentum : 2.79106
Left Arm arm angle : 14.9991
Right Arm D1 momentum : 2.79101
Right Arm arm angle : 15.001
HALLA:p : 2846.04
HALLA:dpp : 0.000134631
Tiefenbach Hall A energy : 2846.04
Left Arm Top VDC Current : 0.927734
Left Arm Bottom VDC Current : -1.46484
Left Arm Q1 momentum : 2.79104
Left Arm Q1 power supply : 2099.79
Left Arm Q1 gauss meter : -0.17714
Left Arm Q2 gauss meter : 0.6319
Left Arm Q2 power supply current : 1201.93
Left Arm Q2 momentum : 2.7913
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 969.035
Left Arm D1 momentum : 2.79106
Left Arm D1 NMR : 1.03331
Left Arm Q3 gauss meter : -0.5625
Left Arm Q3 power supply current : 1111.17
Left Arm Q3 momentum : 2.79106
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 momentum : 2.79045
Right Arm Q1 power supply : 2098.24
Right Arm Q1 gauss meter : -0.05235
Right Arm Q2 power supply current : 1201.27
Right Arm Q2 momentum : 2.79126
Right Arm Q2 gauss meter : 0.6285
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 994.542
Right Arm D1 momentum : 2.79101
Right Arm D1 NMR : 1.03571
Right Arm Q3 power supply current : 1110.41
Right Arm Q3 momentum : 2.79061
Right Arm Q3 gauss meter : 0.4968
Right Arm Q3 power supply polarity : disabled
Average current of the two cavities : 50.6163
Current on Unser monitor : 61.5644
Current on Upstream bcm : 50.6756
Current on Downstream bcm : 50.5569
Upstream Cavity Coefficient : 43.377
Downstream Cavity Coefficient : 42.913
Current on IBC0L02 (source) : 50.2512
Hall C Current : 0
MBSY1c magnet current (amp) : 118.639
MBSY1c Bdl : 711246
Hall A momentum (Tiefenbach) (HALLA:p) : 2846.04
Hall A momentum orbit correction (dpp) : 0.000134277
Hall A setup momentum (MMSHLAE) : 2839.38
Hall A energy (halla_MeV) : 2846.04
Hall C energy (hallc_MeV) : nan
Delta(E)/E width (MV_AI_DXWID) : 1.67439
IPM1C12.XPOS : -0.345665
IPM1H04A.XPOS : -1.93421
IPM1H04A.YPOS : 0.0503082
IPM1H04B.XPOS : -1.99753
IPM1H04B.YPOS : 0.000706136
Left Arm Collimator : 0.871436
HacL_HPE1313A:0_Ch58 : -0.189453
HacL_HPE1313A:0_Ch55 : 23.0957
HacL_HPE1313A:0_Ch54 : 0.00634766
-----
SLI data valid? : Yes
SLI horiz size mm : 0.241345
SLI Energy spread *10^5 : 4.46934
SLI x position : 1.58012
SLI vert. size mm : 0.093123
SLI y position : 1.51737
-----
Target : Beam Left C
Vacuum Pressure : 3.74945e-07
fan frequency loop 1 : 60
fan frequency loop 3 : 59.5
Encoder position : 693531
Target type : 693531
temperature loop 1(1) : 7
temperature loop 1(3) : 7.05
Heat exchange He : 7.4
temperature loop 3(1) : 18.84
temperature loop 3(3) : 19
Heat exchange H2 : 18.5
HPH He loop 1 : 239.35
HPH H2 loop 3 : 194.469