    keyword=End_of_Run_22189
    ****************************
     Run Number: 22189
     End of Run Comment:
    Run_type=Test,target_type=Carbon 50 degs Left,beam_e0=2.839,beam_raster=on,beam_halfwaveplate=out,leftarm_p=2.22892,leftarm_theta=15,leftarm_colli=out,rightarm_p=2.791,rightarm_theta=15,rightarm_colli=out,comment_text=C-left
     
    
    PRESCALE FACTORS:ps1=3   ps2=18   ps3=16777215   ps4=16777215   ps5=65535   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS   : 617387       
    TIME     : 5.185 mins  
    
    DEAD TIME:  10.09%      
    
    TRIGGER RATES:   PRES/REAL
    T1:2189.7/6569.2 Hz   T2:17.5/315.2 Hz   T8: 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1: 681252/2043758  T2:   5448/98072    T8:      4/318581   
    
    AVERAGE CURRENT
    BCM x1 : 60.8882uA  BCM x3 : 60.8281uA  BCM x10: 20.3637uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 : 0.019          BCM u3 : 0.01899        BCM u10: 8.619E-05      
    
    BCM d1 : 0.01888        BCM d3 : 0.01886        BCM d10: 0.01258        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 22189 at Wed Dec 19 18:52:58 EST 2007
    
    Wien angle : 6.19568
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 2.79106
    Left Arm arm angle : 14.9991
    Right Arm D1 momentum : 2.79101
    Right Arm arm angle : 15.001
    HALLA:p : 2845.65
    HALLA:dpp : 0
    Tiefenbach Hall A energy : 2845.65
    Left Arm Top VDC Current : 4.05273
    Left Arm Bottom VDC Current : 3.75977
    Left Arm Q1 momentum : 2.79097
    Left Arm Q1 power supply : 2099.73
    Left Arm Q1 gauss meter : -0.17712
    Left Arm Q2 gauss meter : 0.6318
    Left Arm Q2 power supply current : 1201.93
    Left Arm Q2 momentum : 2.7913
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 969.034
    Left Arm D1 momentum : 2.79106
    Left Arm D1 NMR : 1.03331
    Left Arm Q3 gauss meter : -0.5623
    Left Arm Q3 power supply current : 1110.8
    Left Arm Q3 momentum : 2.79016
    Left Arm Q3 power supply polarity : disabled
    Right Arm Q1 momentum : 2.79045
    Right Arm Q1 power supply : 2098.24
    Right Arm Q1 gauss meter : -0.05233
    Right Arm Q2 power supply current : 1201.27
    Right Arm Q2 momentum : 2.79126
    Right Arm Q2 gauss meter : 0.6284
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 994.542
    Right Arm D1 momentum : 2.791
    Right Arm D1 NMR : 1.03571
    Right Arm Q3 power supply current : 1110.41
    Right Arm Q3 momentum : 2.79061
    Right Arm Q3 gauss meter : 0.4968
    Right Arm Q3 power supply polarity : disabled
    Average current of the two cavities : 0.024693
    Current on Unser monitor : 13.2644
    Current on Upstream bcm : 0.0351015
    Current on Downstream bcm : 0.0142845
    Upstream Cavity Coefficient : 43.377
    Downstream Cavity Coefficient : 42.913
    Current on IBC0L02 (source) : 40.9446
    Hall C Current : 41.01
    MBSY1c magnet current (amp) : 118.639
    MBSY1c Bdl : 711246
    Hall A momentum (Tiefenbach) (HALLA:p) : 2845.65
    Hall A momentum orbit correction (dpp) : 0
    Hall A setup momentum (MMSHLAE) : 2839.38
    Hall A energy (halla_MeV) : 2845.65
    Hall C energy (hallc_MeV) : 3549.77
    Delta(E)/E width (MV_AI_DXWID) : 1.76761
    IPM1C12.XPOS : 0
    IPM1H04A.XPOS : 0
    IPM1H04A.YPOS : 0
    IPM1H04B.XPOS : 0
    IPM1H04B.YPOS : 0
    Left Arm Collimator : 0.871387
    HacL_HPE1313A:0_Ch58 : -0.189453
    HacL_HPE1313A:0_Ch55 : 23.0957
    HacL_HPE1313A:0_Ch54 : 0.00537109
    -----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 1.58012
    SLI vert. size mm : 0
    SLI y position : 1.51737
    -----
    Target : Beam Left C
    Vacuum Pressure : 3.72189e-07
    fan frequency loop 1 : 60
    fan frequency loop 3 : 60
    Encoder position : 693531
    Target type : 693531
    temperature loop 1(1) : 7
    temperature loop 1(3) : 7.05
    Heat exchange He : 7.4
    temperature loop 3(1) : 18.84
    temperature loop 3(3) : 19
    Heat exchange H2 : 18.5
    HPH He loop 1 : 242.628
    HPH H2 loop 3 : 190.924