    keyword=End_of_Run_4335
    ****************************
     Run Number: 4335
     End of Run Comment:
    Run_type=Test,target_type=4He 10cm Loop1 High Pressure,beam_e0=2.839,beam_raster=on,leftarm_p=2.22892,leftarm_theta=15,leftarm_colli=out,rightarm_p=2.791,rightarm_theta=15,rightarm_colli=out,comment_text=He loop3
     
    
    PRESCALE FACTORS:ps1=16777212   ps2=16777215   ps3=2   ps4=1   ps5=65535   ps6=65535   ps7=9999   ps8=65535   
    
    EVENTS   : 441201       
    TIME     : 4.122 mins  
    
    DEAD TIME:  12.00%      
    
    TRIGGER RATES:   PRES/REAL
    T3:1916.8/3833.6 Hz   T4:110.5/110.5 Hz   T5: 0.0/0.0  Hz   T8: 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T3: 474048/948097   T4:  27336/27336    T5:      0/0        T8:      3/253246   
    
    AVERAGE CURRENT
    BCM x1 : 5.0149 uA  BCM x3 : 5.0202 uA  BCM x10: 5.0624 uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 : 0.001243       BCM u3 : 0.001244       BCM u10: 0.001253       
    
    BCM d1 : 0.001237       BCM d3 : 0.001239       BCM d10: 0.001251       
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 4335 at Wed Dec 19 19:13:20 EST 2007
    
    Wien angle : 6.19568
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 2.79106
    Left Arm arm angle : 14.9991
    Right Arm D1 momentum : 2.79101
    Right Arm arm angle : 15.001
    HALLA:p : 2845.38
    HALLA:dpp : -9.532e-05
    Tiefenbach Hall A energy : 2845.38
    Left Arm Top VDC Current : -0.830078
    Left Arm Bottom VDC Current : 2.29492
    Left Arm Q1 momentum : 2.79097
    Left Arm Q1 power supply : 2099.79
    Left Arm Q1 gauss meter : -0.17712
    Left Arm Q2 gauss meter : 0.6317
    Left Arm Q2 power supply current : 1201.93
    Left Arm Q2 momentum : 2.7913
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 969.034
    Left Arm D1 momentum : 2.79106
    Left Arm D1 NMR : 1.03331
    Left Arm Q3 gauss meter : -0.5627
    Left Arm Q3 power supply current : 1111.48
    Left Arm Q3 momentum : 2.79187
    Left Arm Q3 power supply polarity : disabled
    Right Arm Q1 momentum : 2.79045
    Right Arm Q1 power supply : 2098.24
    Right Arm Q1 gauss meter : -0.05235
    Right Arm Q2 power supply current : 1201.27
    Right Arm Q2 momentum : 2.79126
    Right Arm Q2 gauss meter : 0.6285
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 994.542
    Right Arm D1 momentum : 2.791
    Right Arm D1 NMR : 1.03571
    Right Arm Q3 power supply current : 1110.41
    Right Arm Q3 momentum : 2.79061
    Right Arm Q3 gauss meter : 0.4967
    Right Arm Q3 power supply polarity : disabled
    Average current of the two cavities : 5.03369
    Current on Unser monitor : 16.464
    Current on Upstream bcm : 5.04219
    Current on Downstream bcm : 5.02518
    Upstream Cavity Coefficient : 43.377
    Downstream Cavity Coefficient : 42.913
    Current on IBC0L02 (source) : 44.8123
    Hall C Current : 40.56
    MBSY1c magnet current (amp) : 118.639
    MBSY1c Bdl : 711246
    Hall A momentum (Tiefenbach) (HALLA:p) : 2845.4
    Hall A momentum orbit correction (dpp) : -8.82851e-05
    Hall A setup momentum (MMSHLAE) : 2839.38
    Hall A energy (halla_MeV) : 2845.4
    Hall C energy (hallc_MeV) : 3549.65
    Delta(E)/E width (MV_AI_DXWID) : 1.61838
    IPM1C12.XPOS : 0
    IPM1H04A.XPOS : -1.98907
    IPM1H04A.YPOS : 0.0217902
    IPM1H04B.XPOS : -2.00228
    IPM1H04B.YPOS : 0.000931799
    Left Arm Collimator : 0.871436
    HacL_HPE1313A:0_Ch58 : -0.189453
    HacL_HPE1313A:0_Ch55 : 23.0957
    HacL_HPE1313A:0_Ch54 : 0.00585938
    SLI data valid? : Yes
    SLI horiz size mm : 0.241593
    SLI Energy spread *10^5 : 4.47395
    SLI x position : 1.58012
    SLI vert. size mm : 0.0940593
    SLI y position : 1.51737
    -----
    Target : L1 10cm
    fan frequency loop 1 : 59.5
    fan frequency loop 3 : 60
    Encoder position : 3.30403e+07
    Target type : 3.30403e+07
    temperature loop 1(1) : 7
    temperature loop 1(3) : 7.05
    Heat exchange He : 7.4
    temperature loop 3(1) : 18.85
    temperature loop 3(3) : 19
    Heat exchange H2 : 18.5
    HPH He loop 1 : 224.876
    HPH He loop 2 : 6.46465
    HPH H2 loop 3 : 183.933
    -----