Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name adev

    Log entry time 19:19:29 on December 19, 2007

    Entry number 222259

    keyword=End_of_Run_22192
    ****************************
     Run Number: 22192
     End of Run Comment:
    Run_type=Test,target_type=4He 10cm Loop1 High Pressure,beam_e0=2.839,beam_raster=on,beam_halfwaveplate=out,leftarm_p=2.22892,leftarm_theta=15,leftarm_colli=out,rightarm_p=2.791,rightarm_theta=15,rightarm_colli=out,comment_text=He loop1
     
    
    PRESCALE FACTORS:ps1=2   ps2=2   ps3=16777215   ps4=16777215   ps5=65535   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS   : 824312       
    TIME     : 4.604 mins  
    
    DEAD TIME:  25.14%      
    
    TRIGGER RATES:   PRES/REAL
    T1:3771.7/7543.4 Hz   T2:214.4/428.7 Hz   T8: 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1:1041933/2083867  T2:  59218/118437   T8:      4/282879   
    
    AVERAGE CURRENT
    BCM x1 : 9.8718 uA  BCM x3 : 9.8783 uA  BCM x10: 5.1139 uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 : 0.002735       BCM u3 : 0.002735       BCM u10: 8.835E-05      
    
    BCM d1 : 0.002719       BCM d3 : 0.002722       BCM d10: 0.002737       
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 22192 at Wed Dec 19 19:19:26 EST 2007
    
    Wien angle : 6.19568
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 2.79106
    Left Arm arm angle : 14.9991
    Right Arm D1 momentum : 2.791
    Right Arm arm angle : 15.001
    HALLA:p : 2845.41
    HALLA:dpp : -8.6466e-05
    Tiefenbach Hall A energy : 2845.41
    Left Arm Top VDC Current : -2.34375
    Left Arm Bottom VDC Current : 1.95312
    Left Arm Q1 momentum : 2.79104
    Left Arm Q1 power supply : 2099.79
    Left Arm Q1 gauss meter : -0.17714
    Left Arm Q2 gauss meter : 0.6318
    Left Arm Q2 power supply current : 1201.94
    Left Arm Q2 momentum : 2.79132
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 969.034
    Left Arm D1 momentum : 2.79106
    Left Arm D1 NMR : 1.03331
    Left Arm Q3 gauss meter : -0.5625
    Left Arm Q3 power supply current : 1111.14
    Left Arm Q3 momentum : 2.79096
    Left Arm Q3 power supply polarity : disabled
    Right Arm Q1 momentum : 2.79045
    Right Arm Q1 power supply : 2098.24
    Right Arm Q1 gauss meter : -0.05235
    Right Arm Q2 power supply current : 1201.27
    Right Arm Q2 momentum : 2.79127
    Right Arm Q2 gauss meter : 0.6285
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 994.54
    Right Arm D1 momentum : 2.791
    Right Arm D1 NMR : 1.03571
    Right Arm Q3 power supply current : 1110.41
    Right Arm Q3 momentum : 2.79061
    Right Arm Q3 gauss meter : 0.4967
    Right Arm Q3 power supply polarity : disabled
    Average current of the two cavities : 9.90161
    Current on Unser monitor : 22.2938
    Current on Upstream bcm : 9.88854
    Current on Downstream bcm : 9.91468
    Upstream Cavity Coefficient : 43.377
    Downstream Cavity Coefficient : 42.913
    Current on IBC0L02 (source) : 49.4421
    Hall C Current : 39.48
    MBSY1c magnet current (amp) : 118.639
    MBSY1c Bdl : 711246
    Hall A momentum (Tiefenbach) (HALLA:p) : 2845.41
    Hall A momentum orbit correction (dpp) : -8.44536e-05
    Hall A setup momentum (MMSHLAE) : 2839.38
    Hall A energy (halla_MeV) : 2845.41
    Hall C energy (hallc_MeV) : 3549.67
    Delta(E)/E width (MV_AI_DXWID) : 1.59799
    IPM1C12.XPOS : 0
    IPM1H04A.XPOS : -1.98784
    IPM1H04A.YPOS : 0.0239027
    IPM1H04B.XPOS : -2.00397
    IPM1H04B.YPOS : -0.000719905
    Left Arm Collimator : 0.871387
    HacL_HPE1313A:0_Ch58 : -0.188965
    HacL_HPE1313A:0_Ch55 : 23.0957
    HacL_HPE1313A:0_Ch54 : 0.00585938
    -----
    SLI data valid? : Yes
    SLI horiz size mm : 0.21477
    SLI Energy spread *10^5 : 3.97722
    SLI x position : 1.58012
    SLI vert. size mm : 0.101759
    SLI y position : 1.51737
    -----
    Target : L1 10cm
    Vacuum Pressure : 3.45959e-07
    fan frequency loop 1 : 60
    fan frequency loop 3 : 60
    Encoder position : 3.30403e+07
    Target type : 3.30403e+07
    temperature loop 1(1) : 6.99
    temperature loop 1(3) : 7.06
    Heat exchange He : 7.4
    temperature loop 3(1) : 18.84
    temperature loop 3(3) : 19
    Heat exchange H2 : 18.5
    HPH He loop 1 : 217.809
    HPH H2 loop 3 : 189.515