Run Number: 4336
End of Run Comment:
Run_type=Test,target_type=4He 10cm Loop1 High Pressure,beam_e0=2.839,beam_raster=on,leftarm_p=2.22892,leftarm_theta=15,leftarm_colli=out,rightarm_p=2.791,rightarm_theta=15,rightarm_colli=out,comment_text=He loop3
PRESCALE FACTORS:ps1=16777212 ps2=16777215 ps3=2 ps4=2 ps5=65535 ps6=65535 ps7=9999 ps8=65535
EVENTS : 809128
TIME : 4.596 mins
DEAD TIME: 24.01%
TRIGGER RATES: PRES/REAL
T3:3747.2/7494.4 Hz T4:114.3/228.7 Hz T5: 0.0/0.0 Hz T8: 0.0/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T3:1033305/2066611 T4: 31528/63057 T5: 0/0 T8: 4/282373
AVERAGE CURRENT
BCM x1 : 9.8575 uA BCM x3 : 9.8645 uA BCM x10: 9.9462 uA
APPROXIMATE BCM CHARGES (C)
BCM u1 : 0.002725 BCM u3 : 0.002726 BCM u10: 0.002746
BCM d1 : 0.002712 BCM d3 : 0.002714 BCM d10: 0.002739
****************************
End-of-run EPICS data for Run Number 4336 at Wed Dec 19 19:19:27 EST 2007
Wien angle : 6.19568
Half-wave plate (off=out) : IN
Left Arm D1 momentum : 2.79106
Left Arm arm angle : 14.9991
Right Arm D1 momentum : 2.791
Right Arm arm angle : 15.001
HALLA:p : 2845.41
HALLA:dpp : -8.44536e-05
Tiefenbach Hall A energy : 2845.41
Left Arm Top VDC Current : 4.10156
Left Arm Bottom VDC Current : 0.927734
Left Arm Q1 momentum : 2.79104
Left Arm Q1 power supply : 2099.79
Left Arm Q1 gauss meter : -0.17713
Left Arm Q2 gauss meter : 0.6318
Left Arm Q2 power supply current : 1201.94
Left Arm Q2 momentum : 2.79132
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 969.034
Left Arm D1 momentum : 2.79106
Left Arm D1 NMR : 1.03331
Left Arm Q3 gauss meter : -0.5625
Left Arm Q3 power supply current : 1111.14
Left Arm Q3 momentum : 2.79097
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 momentum : 2.79045
Right Arm Q1 power supply : 2098.24
Right Arm Q1 gauss meter : -0.05235
Right Arm Q2 power supply current : 1201.27
Right Arm Q2 momentum : 2.79127
Right Arm Q2 gauss meter : 0.6285
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 994.54
Right Arm D1 momentum : 2.791
Right Arm D1 NMR : 1.03571
Right Arm Q3 power supply current : 1110.41
Right Arm Q3 momentum : 2.79061
Right Arm Q3 gauss meter : 0.4967
Right Arm Q3 power supply polarity : disabled
Average current of the two cavities : 9.90161
Current on Unser monitor : 22.3024
Current on Upstream bcm : 9.88854
Current on Downstream bcm : 9.91468
Upstream Cavity Coefficient : 43.377
Downstream Cavity Coefficient : 42.913
Current on IBC0L02 (source) : 49.4421
Hall C Current : 39.63
MBSY1c magnet current (amp) : 118.639
MBSY1c Bdl : 711246
Hall A momentum (Tiefenbach) (HALLA:p) : 2845.41
Hall A momentum orbit correction (dpp) : -8.44536e-05
Hall A setup momentum (MMSHLAE) : 2839.38
Hall A energy (halla_MeV) : 2845.41
Hall C energy (hallc_MeV) : 3549.67
Delta(E)/E width (MV_AI_DXWID) : 1.6379
IPM1C12.XPOS : 0
IPM1H04A.XPOS : -1.98881
IPM1H04A.YPOS : 0.028333
IPM1H04B.XPOS : -2.01176
IPM1H04B.YPOS : -0.00139725
Left Arm Collimator : 0.871387
HacL_HPE1313A:0_Ch58 : -0.189453
HacL_HPE1313A:0_Ch55 : 23.0957
HacL_HPE1313A:0_Ch54 : 0.00537109
SLI data valid? : Yes
SLI horiz size mm : 0.21477
SLI Energy spread *10^5 : 3.97722
SLI x position : 1.58012
SLI vert. size mm : 0.101759
SLI y position : 1.51737
-----
Target : L1 10cm
fan frequency loop 1 : 60
fan frequency loop 3 : 60
Encoder position : 3.30403e+07
Target type : 3.30403e+07
temperature loop 1(1) : 7
temperature loop 1(3) : 7.06
Heat exchange He : 7.4
temperature loop 3(1) : 18.84
temperature loop 3(3) : 19
Heat exchange H2 : 18.5
HPH He loop 1 : 217.809
HPH He loop 2 : 6.97365
HPH H2 loop 3 : 189.515
-----