Privacy and Security Notice
Main INDEX
Monthly INDEX
PREV
NEXT
User name a-onl
Log entry time 19:33:51 on December 19, 2007
Entry number 222268
keyword=End_of_Run_4338
****************************
Run Number: 4338
End of Run Comment:
Run_type=Test,target_type=4He 10cm Loop1 High Pressure,beam_e0=2.839,beam_raster=on,leftarm_p=2.22892,leftarm_theta=15,leftarm_colli=out,rightarm_p=2.791,rightarm_theta=15,rightarm_colli=out,comment_text=He loop3
PRESCALE FACTORS:ps1=16777212 ps2=16777215 ps3=6 ps4=35 ps5=65535 ps6=65535 ps7=9999 ps8=65535
EVENTS : 1016230
TIME : 5.374 mins
DEAD TIME: 9.10%
TRIGGER RATES: PRES/REAL
T3:3447.5/20685.0 Hz T4:19.7/690.8 Hz T5: 0.0/0.0 Hz T8: 0.0/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T3:1111653/6669919 T4: 6363/222735 T5: 0/0 T8: 5/330191
AVERAGE CURRENT
BCM x1 : 27.4653uA BCM x3 : 27.4704uA BCM x10: 27.3148uA
APPROXIMATE BCM CHARGES (C)
BCM u1 : 0.008874 BCM u3 : 0.008876 BCM u10: 0.00889
BCM d1 : 0.008838 BCM d3 : 0.00884 BCM d10: 0.008726
****************************
End-of-run EPICS data for Run Number 4338 at Wed Dec 19 19:33:48 EST 2007
Wien angle : 6.19568
Half-wave plate (off=out) : IN
Left Arm D1 momentum : 2.79106
Left Arm arm angle : 14.9991
Right Arm D1 momentum : 2.79099
Right Arm arm angle : 15.001
HALLA:p : 2846.81
HALLA:dpp : 0.000405581
Tiefenbach Hall A energy : 2846.81
Left Arm Top VDC Current : 1.5625
Left Arm Bottom VDC Current : -2.05078
Left Arm Q1 momentum : 2.79104
Left Arm Q1 power supply : 2099.79
Left Arm Q1 gauss meter : -0.17713
Left Arm Q2 gauss meter : 0.6318
Left Arm Q2 power supply current : 1201.93
Left Arm Q2 momentum : 2.7913
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 969.035
Left Arm D1 momentum : 2.79106
Left Arm D1 NMR : 1.03331
Left Arm Q3 gauss meter : -0.5625
Left Arm Q3 power supply current : 1111.04
Left Arm Q3 momentum : 2.79073
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 momentum : 2.79045
Right Arm Q1 power supply : 2098.24
Right Arm Q1 gauss meter : -0.05234
Right Arm Q2 power supply current : 1201.26
Right Arm Q2 momentum : 2.79125
Right Arm Q2 gauss meter : 0.6284
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 994.541
Right Arm D1 momentum : 2.79099
Right Arm D1 NMR : 1.0357
Right Arm Q3 power supply current : 1110.4
Right Arm Q3 momentum : 2.7906
Right Arm Q3 gauss meter : 0.4967
Right Arm Q3 power supply polarity : disabled
Average current of the two cavities : 30.0261
Current on Unser monitor : 41.9613
Current on Upstream bcm : 30.0557
Current on Downstream bcm : 29.9966
Upstream Cavity Coefficient : 43.377
Downstream Cavity Coefficient : 42.913
Current on IBC0L02 (source) : 69.4699
Hall C Current : 39.87
MBSY1c magnet current (amp) : 118.639
MBSY1c Bdl : 711246
Hall A momentum (Tiefenbach) (HALLA:p) : 2846.81
Hall A momentum orbit correction (dpp) : 0.000405581
Hall A setup momentum (MMSHLAE) : 2839.38
Hall A energy (halla_MeV) : 2846.81
Hall C energy (hallc_MeV) : 3549.6
Delta(E)/E width (MV_AI_DXWID) : 1.72471
IPM1C12.XPOS : 0
IPM1H04A.XPOS : -2.00654
IPM1H04A.YPOS : -0.0486454
IPM1H04B.XPOS : -2.02193
IPM1H04B.YPOS : -0.0705808
Left Arm Collimator : 0.871387
HacL_HPE1313A:0_Ch58 : -0.189453
HacL_HPE1313A:0_Ch55 : 23.1445
HacL_HPE1313A:0_Ch54 : 0.00585938
SLI data valid? : Yes
SLI horiz size mm : 0.221373
SLI Energy spread *10^5 : 4.09949
SLI x position : 1.56522
SLI vert. size mm : 0.0831068
SLI y position : 1.51737
-----
Target : L1 10cm
fan frequency loop 1 : 59.5
fan frequency loop 3 : 60
Encoder position : 3.30403e+07
Target type : 3.30403e+07
temperature loop 1(1) : 7
temperature loop 1(3) : 7.1
Heat exchange He : 7.5
temperature loop 3(1) : 18.85
temperature loop 3(3) : 19.01
Heat exchange H2 : 18.5
HPH He loop 1 : 154.65
HPH He loop 2 : 6.97365
HPH H2 loop 3 : 195.181
-----