Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name adev

    Log entry time 19:46:59 on December 19, 2007

    Entry number 222276

    keyword=End_of_Run_22196
    ****************************
     Run Number: 22196
     End of Run Comment:
    Run_type=Test,target_type=4He 10cm Loop1 High Pressure,beam_e0=2.839,beam_raster=on,beam_halfwaveplate=out,leftarm_p=2.22892,leftarm_theta=15,leftarm_colli=out,rightarm_p=2.791,rightarm_theta=15,rightarm_colli=out,comment_text=He loop1
     
    
    PRESCALE FACTORS:ps1=9   ps2=150   ps3=16777215   ps4=16777215   ps5=65535   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS   : 1011798      
    TIME     : 4.347 mins  
    
    DEAD TIME:   8.04%      
    
    TRIGGER RATES:   PRES/REAL
    T1:4196.9/37772.3 Hz   T2:21.8/3265.8 Hz   T8: 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1:1094594/9851346  T2:   5678/851744   T8:      4/267068   
    
    AVERAGE CURRENT
    BCM x1 : 50.2702uA  BCM x3 : 50.2561uA  BCM x10: 22.6761uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 : 0.01315        BCM u3 : 0.01315        BCM u10: 0.0004382      
    
    BCM d1 : 0.01307        BCM d3 : 0.01307        BCM d10: 0.01139        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 22196 at Wed Dec 19 19:46:56 EST 2007
    
    Wien angle : 6.19568
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 2.79106
    Left Arm arm angle : 14.9991
    Right Arm D1 momentum : 2.79101
    Right Arm arm angle : 15.001
    HALLA:p : 2846.86
    HALLA:dpp : 0.000425045
    Tiefenbach Hall A energy : 2846.86
    Left Arm Top VDC Current : -6.83594
    Left Arm Bottom VDC Current : -5.17578
    Left Arm Q1 momentum : 2.79097
    Left Arm Q1 power supply : 2099.73
    Left Arm Q1 gauss meter : -0.17712
    Left Arm Q2 gauss meter : 0.6317
    Left Arm Q2 power supply current : 1201.94
    Left Arm Q2 momentum : 2.79131
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 969.035
    Left Arm D1 momentum : 2.79106
    Left Arm D1 NMR : 1.03331
    Left Arm Q3 gauss meter : -0.5625
    Left Arm Q3 power supply current : 1111.05
    Left Arm Q3 momentum : 2.79075
    Left Arm Q3 power supply polarity : disabled
    Right Arm Q1 momentum : 2.79045
    Right Arm Q1 power supply : 2098.24
    Right Arm Q1 gauss meter : -0.05235
    Right Arm Q2 power supply current : 1201.27
    Right Arm Q2 momentum : 2.79126
    Right Arm Q2 gauss meter : 0.6285
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 994.542
    Right Arm D1 momentum : 2.79101
    Right Arm D1 NMR : 1.03571
    Right Arm Q3 power supply current : 1110.41
    Right Arm Q3 momentum : 2.7906
    Right Arm Q3 gauss meter : 0.4968
    Right Arm Q3 power supply polarity : disabled
    Average current of the two cavities : 50.2261
    Current on Unser monitor : 61.8344
    Current on Upstream bcm : 50.2595
    Current on Downstream bcm : 50.2619
    Upstream Cavity Coefficient : 43.377
    Downstream Cavity Coefficient : 42.913
    Current on IBC0L02 (source) : 89.3299
    Hall C Current : 40.26
    MBSY1c magnet current (amp) : 118.639
    MBSY1c Bdl : 711246
    Hall A momentum (Tiefenbach) (HALLA:p) : 2846.87
    Hall A momentum orbit correction (dpp) : 0.000426223
    Hall A setup momentum (MMSHLAE) : 2839.38
    Hall A energy (halla_MeV) : 2846.87
    Hall C energy (hallc_MeV) : 3549.57
    Delta(E)/E width (MV_AI_DXWID) : 1.57631
    IPM1C12.XPOS : 0
    IPM1H04A.XPOS : -1.98954
    IPM1H04A.YPOS : 0.0230251
    IPM1H04B.XPOS : -2.00874
    IPM1H04B.YPOS : -0.0145673
    Left Arm Collimator : 0.871436
    HacL_HPE1313A:0_Ch58 : -0.189453
    HacL_HPE1313A:0_Ch55 : 23.0957
    HacL_HPE1313A:0_Ch54 : 0.00585938
    -----
    SLI data valid? : Yes
    SLI horiz size mm : 0.228049
    SLI Energy spread *10^5 : 4.22312
    SLI x position : 1.56522
    SLI vert. size mm : 0.0910808
    SLI y position : 1.51737
    -----
    Target : L1 10cm
    Vacuum Pressure : 4.05932e-07
    fan frequency loop 1 : 59.5
    fan frequency loop 3 : 60
    Encoder position : 3.30403e+07
    Target type : 3.30403e+07
    temperature loop 1(1) : 7
    temperature loop 1(3) : 7.13
    Heat exchange He : 7.5
    temperature loop 3(1) : 18.85
    temperature loop 3(3) : 19
    Heat exchange H2 : 18.5
    HPH He loop 1 : 82.9997
    HPH H2 loop 3 : 188.813