Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name adev

    Log entry time 19:54:20 on December 19, 2007

    Entry number 222280

    keyword=End_of_Run_22197
    ****************************
     Run Number: 22197
     End of Run Comment:
    Run_type=Test,target_type=4He 10cm Loop1 High Pressure,beam_e0=2.839,beam_raster=on,beam_halfwaveplate=out,leftarm_p=2.22892,leftarm_theta=15,leftarm_colli=out,rightarm_p=2.791,rightarm_theta=15,rightarm_colli=out,comment_text=He loop1
     
    
    PRESCALE FACTORS:ps1=11   ps2=200   ps3=16777215   ps4=16777215   ps5=65535   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS   : 1070781      
    TIME     : 4.639 mins  
    
    DEAD TIME:   6.92%      
    
    TRIGGER RATES:   PRES/REAL
    T1:4112.2/45234.3 Hz   T2:21.2/4235.0 Hz   T8: 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1:1144532/12589852  T2:   5893/1178695  T8:      4/285005   
    
    AVERAGE CURRENT
    BCM x1 : 60.2959uA  BCM x3 : 60.2626uA  BCM x10: 23.7535uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 : 0.01684        BCM u3 : 0.01683        BCM u10: 0.0005611      
    
    BCM d1 : 0.01672        BCM d3 : 0.01672        BCM d10: 0.01266        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 22197 at Wed Dec 19 19:54:17 EST 2007
    
    Wien angle : 6.19568
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 2.79106
    Left Arm arm angle : 14.9991
    Right Arm D1 momentum : 2.79101
    Right Arm arm angle : 15.001
    HALLA:p : 2846.87
    HALLA:dpp : 0.000425791
    Tiefenbach Hall A energy : 2846.87
    Left Arm Top VDC Current : -7.8125
    Left Arm Bottom VDC Current : -0.976562
    Left Arm Q1 momentum : 2.79104
    Left Arm Q1 power supply : 2099.73
    Left Arm Q1 gauss meter : -0.17713
    Left Arm Q2 gauss meter : 0.6318
    Left Arm Q2 power supply current : 1201.94
    Left Arm Q2 momentum : 2.79131
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 969.034
    Left Arm D1 momentum : 2.79106
    Left Arm D1 NMR : 1.03331
    Left Arm Q3 gauss meter : -0.5625
    Left Arm Q3 power supply current : 1111.13
    Left Arm Q3 momentum : 2.79094
    Left Arm Q3 power supply polarity : disabled
    Right Arm Q1 momentum : 2.79045
    Right Arm Q1 power supply : 2098.24
    Right Arm Q1 gauss meter : -0.05235
    Right Arm Q2 power supply current : 1201.27
    Right Arm Q2 momentum : 2.79126
    Right Arm Q2 gauss meter : 0.6285
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 994.541
    Right Arm D1 momentum : 2.791
    Right Arm D1 NMR : 1.03571
    Right Arm Q3 power supply current : 1110.41
    Right Arm Q3 momentum : 2.79061
    Right Arm Q3 gauss meter : 0.4968
    Right Arm Q3 power supply polarity : disabled
    Average current of the two cavities : 60.0093
    Current on Unser monitor : 71.1793
    Current on Upstream bcm : 60.1855
    Current on Downstream bcm : 59.8331
    Upstream Cavity Coefficient : 43.377
    Downstream Cavity Coefficient : 42.913
    Current on IBC0L02 (source) : 98.6045
    Hall C Current : 39.33
    MBSY1c magnet current (amp) : 118.639
    MBSY1c Bdl : 711246
    Hall A momentum (Tiefenbach) (HALLA:p) : 2846.87
    Hall A momentum orbit correction (dpp) : 0.000425923
    Hall A setup momentum (MMSHLAE) : 2839.38
    Hall A energy (halla_MeV) : 2846.87
    Hall C energy (hallc_MeV) : 3549.68
    Delta(E)/E width (MV_AI_DXWID) : 1.63287
    IPM1C12.XPOS : 0
    IPM1H04A.XPOS : -1.95962
    IPM1H04A.YPOS : 0.0315381
    IPM1H04B.XPOS : -1.97718
    IPM1H04B.YPOS : -0.00624251
    Left Arm Collimator : 0.871436
    HacL_HPE1313A:0_Ch58 : -0.189941
    HacL_HPE1313A:0_Ch55 : 23.0957
    HacL_HPE1313A:0_Ch54 : 0.00585938
    -----
    SLI data valid? : Yes
    SLI horiz size mm : 0.259525
    SLI Energy spread *10^5 : 4.80602
    SLI x position : 1.58012
    SLI vert. size mm : 0.0916477
    SLI y position : 1.51737
    -----
    Target : L1 10cm
    Vacuum Pressure : 4.20744e-07
    fan frequency loop 1 : 60
    fan frequency loop 3 : 60
    Encoder position : 3.30403e+07
    Target type : 3.30403e+07
    temperature loop 1(1) : 7
    temperature loop 1(3) : 7.14
    Heat exchange He : 7.5
    temperature loop 3(1) : 18.85
    temperature loop 3(3) : 19
    Heat exchange H2 : 18.5
    HPH He loop 1 : 47.1568
    HPH H2 loop 3 : 194.469