Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 19:54:22 on December 19, 2007

    Entry number 222281

    keyword=End_of_Run_4341
    ****************************
     Run Number: 4341
     End of Run Comment:
    Run_type=Test,target_type=4He 10cm Loop1 High Pressure,beam_e0=2.839,beam_raster=on,leftarm_p=2.22892,leftarm_theta=15,leftarm_colli=out,rightarm_p=2.791,rightarm_theta=15,rightarm_colli=out,comment_text=He loop3
     
    
    PRESCALE FACTORS:ps1=16777212   ps2=16777215   ps3=11   ps4=75   ps5=65535   ps6=65535   ps7=9999   ps8=65535   
    
    EVENTS   : 1073083      
    TIME     : 4.640 mins  
    
    DEAD TIME:   6.07%      
    
    TRIGGER RATES:   PRES/REAL
    T3:4080.5/44885.9 Hz   T4:23.5/1759.1 Hz   T5: 0.0/0.0  Hz   T8: 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T3:1135946/12495406  T4:   6529/489696   T5:      0/0        T8:      4/285063   
    
    AVERAGE CURRENT
    BCM x1 : 60.2052uA  BCM x3 : 60.1750uA  BCM x10: 46.0104uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 : 0.01681        BCM u3 : 0.01681        BCM u10: 0.01292        
    
    BCM d1 : 0.01671        BCM d3 : 0.0167         BCM d10: 0.0127         
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 4341 at Wed Dec 19 19:54:18 EST 2007
    
    Wien angle : 6.19568
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 2.79106
    Left Arm arm angle : 14.9991
    Right Arm D1 momentum : 2.791
    Right Arm arm angle : 15.001
    HALLA:p : 2846.87
    HALLA:dpp : 0.000425923
    Tiefenbach Hall A energy : 2846.87
    Left Arm Top VDC Current : -1.2207
    Left Arm Bottom VDC Current : -0.927734
    Left Arm Q1 momentum : 2.79097
    Left Arm Q1 power supply : 2099.73
    Left Arm Q1 gauss meter : -0.17713
    Left Arm Q2 gauss meter : 0.6319
    Left Arm Q2 power supply current : 1201.94
    Left Arm Q2 momentum : 2.79131
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 969.036
    Left Arm D1 momentum : 2.79106
    Left Arm D1 NMR : 1.03331
    Left Arm Q3 gauss meter : -0.5625
    Left Arm Q3 power supply current : 1111.13
    Left Arm Q3 momentum : 2.79094
    Left Arm Q3 power supply polarity : disabled
    Right Arm Q1 momentum : 2.79045
    Right Arm Q1 power supply : 2098.24
    Right Arm Q1 gauss meter : -0.05235
    Right Arm Q2 power supply current : 1201.27
    Right Arm Q2 momentum : 2.79126
    Right Arm Q2 gauss meter : 0.6284
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 994.541
    Right Arm D1 momentum : 2.791
    Right Arm D1 NMR : 1.03571
    Right Arm Q3 power supply current : 1110.41
    Right Arm Q3 momentum : 2.79061
    Right Arm Q3 gauss meter : 0.4968
    Right Arm Q3 power supply polarity : disabled
    Average current of the two cavities : 59.9571
    Current on Unser monitor : 71.1793
    Current on Upstream bcm : 60.1855
    Current on Downstream bcm : 59.7288
    Upstream Cavity Coefficient : 43.377
    Downstream Cavity Coefficient : 42.913
    Current on IBC0L02 (source) : 98.6272
    Hall C Current : 39.33
    MBSY1c magnet current (amp) : 118.639
    MBSY1c Bdl : 711246
    Hall A momentum (Tiefenbach) (HALLA:p) : 2846.87
    Hall A momentum orbit correction (dpp) : 0.000426784
    Hall A setup momentum (MMSHLAE) : 2839.38
    Hall A energy (halla_MeV) : 2846.87
    Hall C energy (hallc_MeV) : 3549.72
    Delta(E)/E width (MV_AI_DXWID) : 1.59091
    IPM1C12.XPOS : 0
    IPM1H04A.XPOS : -1.96275
    IPM1H04A.YPOS : 0.0373465
    IPM1H04B.XPOS : -1.98401
    IPM1H04B.YPOS : 0.00600117
    Left Arm Collimator : 0.871436
    HacL_HPE1313A:0_Ch58 : -0.189941
    HacL_HPE1313A:0_Ch55 : 23.0957
    HacL_HPE1313A:0_Ch54 : 0.00585938
    SLI data valid? : Yes
    SLI horiz size mm : 0.259525
    SLI Energy spread *10^5 : 4.80602
    SLI x position : 1.58012
    SLI vert. size mm : 0.0916477
    SLI y position : 1.51737
    -----
    Target : L1 10cm
    fan frequency loop 1 : 59.5
    fan frequency loop 3 : 59.5
    Encoder position : 3.30403e+07
    Target type : 3.30403e+07
    temperature loop 1(1) : 7
    temperature loop 1(3) : 7.14
    Heat exchange He : 7.5
    temperature loop 3(1) : 18.85
    temperature loop 3(3) : 19
    Heat exchange H2 : 18.5
    HPH He loop 1 : 47.1568
    HPH He loop 2 : 6.71674
    HPH H2 loop 3 : 194.469
    -----